|
Yue, Z. et al, Algora, A., & Nacher, E. (2024). Magnetic moments of thallium isotopes in the vicinity of magic N=126. Phys. Lett. B, 849, 138452–7pp.
Abstract: The magnetic dipole moments (mu) of Tl-209(g)(N =128) and Tl-207(m)(N = 126) have been measured for the first time using the in -source laser resonance -ionization spectroscopy technique with the Laser Ion Source and Trap (LIST) at ISOLDE (CERN). The application of the LIST suppresses the usually overwhelming background of the isobaric francium isotopes and allows access to heavy thallium isotopes with >207. The self -consistent theory of finite Fermi systems based on the energy density functional by Fayans et al. well describes the N dependence of μfor 1/2(+) thallium ground states, as well as μfor the 11/2(-) isomeric states in europium, gold and thallium isotopes. The inclusion of particle-vibration coupling leads to a better agreement between the theory and experiment for mu(Tl-g , I-pi = 1/2(+)). It is shown that beyond mean-field contributions tocannot be neglected at least for thallium isotopes with I-pi = 1/2(+).
|
|
|
LHCb Collaboration(Aaij, R. et al), Martinez-Vidal, F., Oyanguren, A., Ruiz Valls, P., & Sanchez Mayordomo, C. (2016). Measurement of the properties of the Xi(b)(*0) baryon. J. High Energy Phys., 05(5), 161–19pp.
Abstract: We perform a search for near-threshold I (b) (0) resonances decaying to I (b) (-) pi (+) in a sample of proton-proton collision data corresponding to an integrated luminosity of 3 fb(-1) collected by the LHCb experiment. We observe one resonant state, with the following properties: m(Xi b*0) – m (Xi b-) – m (pi+) = 15.727 +/- 0.068 (stat) +/- 0.023 (syst) MeV/c2, Gamma(Xi b*0) = 0.90 +/- 0.16 (stat) +/- 0.08 (syst) MeV. This confirms the previous observation by the CMS collaboration. The state is consistent with the J (P) = 3/2(+)aEuro integral I (b) (au 0) resonance expected in the quark model. This is the most precise determination of the mass and the first measurement of the natural width of this state. We have also measured the ratio sigma(pp -> Xi b*0 X)B(Xi b*0 -> Xi b-pi+)/sigma(pp -> Xi b- X) = 0.28 +/- 0.03 (stat.) +/- 0.01 (syst).
|
|
|
LHCb Collaboration(Aaij, R. et al), Garcia Martin, L. M., Henry, L., Martinez-Vidal, F., Oyanguren, A., Remon Alepuz, C., et al. (2018). Measurements of the branching fractions of Lambda(+)(c) -> p pi(-)pi(+), Lambda(+)(c) -> pK(-)K(+), and Lambda(+)(c) -> p pi K-(+). J. High Energy Phys., 03(3), 043–23pp.
Abstract: The ratios of the branching fractions of the decays do Lambda(+)(c) -> , p pi(-)pi(+), Lambda(+->)(c) pK(-)K(+), and Lambda(+)(c) -> p pi K--(+) with respect to the Cabibbo-favoured Lambda(+)(c) -> pK(-)pi(+) decay are measured using proton-proton collision data collected with the LHCb experiment at a 7 TeV centre-of-mass energy and corresponding to an integrated luminosity of 1.0 fb(-1): B(Lambda(+)(c) -> p pi(-)pi(+))/B(Lambda(+)(c) -> pK(-)pi(+)) = (7.44 +/- 0.08 +/- 0.18)%. B(Lambda(+)(c) -> pK(-)K(+))/B(Lambda(+)(c) -> pK(-)pi(+) = (1.70 +/- 0.03 +/- 0.03)%, B(Lambda(+)(c) -> p pi(-)pi K-+(+))/B(Lambda(+)(c) -> pK(-)pi(+) = (0.165 +/- 0.015 +/- 0.005)%, where the uncertainties are statistical and systematic, respectively. These results are the most precise measurements of these quantities to date. When multiplied by the world average value for B(Lambda(+)(c) -> p pi(-)pi(+)), the corresponding branching fractions are B(Lambda(+)(c) -> p pi(-)pi(+) = (4.72 +/- 0.05 +/- 0.11 +/- 0.25) x 10(-3), B(Lambda(+)(c) -> pK(-)K(+)) = (1.08 +/- 0.02 +/- 0.02 +/- 0.06) x 10(-3), B(Lambda(+)(c) -> , p pi K--(+)) = (1.04 +/- 0.09 +/- 0.03 +/- 0.05) x 10(-4), where the final uncertainty is due to B(Lambda(+)(c) -> pK(-)pi(+)).
|
|
|
Garcia, A. R., Martinez, T., Cano-Ott, D., Castilla, J., Guerrero, C., Marin, J., et al. (2012). MONSTER: a time of flight spectrometer for beta-delayed neutron emission measurements. J. Instrum., 7, C05012–12pp.
Abstract: The knowledge of the beta-decay properties of nuclei contributes decisively to our understanding of nuclear phenomena: the beta-delayed neutron emission of neutron rich nuclei plays an important role in the nucleosynthesis r-process and constitutes a probe for nuclear structure of very neutron rich nuclei providing information about the high energy part of the full beta strength (S-beta) function. In addition, beta-delayed neutrons are essential for the control and safety of nuclear reactors. In order to determine the neutron energy spectra and emission probabilities from neutron precursors a MOdular Neutron time-of-flight SpectromeTER (MONSTER) has been proposed for the DESPEC experiment at the future FAIR facility. The design of MONSTER and status of its construction are reported in this work.
|
|
|
Valiente-Dobon, J. J. et al, Egea, J., Huyuk, T., Gadea, A., Aliaga, R., Jurado-Gomez, M. L., et al. (2019). NEDA-NEutron Detector Array. Nucl. Instrum. Methods Phys. Res. A, 927, 81–86.
Abstract: The NEutron Detector Array, NEDA, will form the next generation neutron detection system that has been designed to be operated in conjunction with gamma-ray arrays, such as the tracking-array AGATA, to aid nuclear spectroscopy studies. NEDA has been designed to be a versatile device, with high-detection efficiency, excellent neutron-gamma discrimination, and high rate capabilities. It will be employed in physics campaigns in order to maximise the scientific output, making use of the different stable and radioactive ion beams available in Europe. The first implementation of the neutron detector array NEDA with AGATA 1 pi was realised at GANIL. This manuscript reviews the various aspects of NEDA.
|
|