|
Nacher, E., Rubio, B., Algora, A., Cano-Ott, D., Tain, J. L., Gadea, A., et al. (2016). Observations of the Gamow-Teller resonance in the rare-earth nuclei above Gd-146 populated in beta decay. Phys. Rev. C, 93(1), 014308–13pp.
Abstract: The rare-earth region of the nuclear table around the quasi-doubly magic nucleus Gd-146 is one of the very few places in which the Gamow-Teller (GT) resonance can be populated in beta decay. The appropriate technique to study such a phenomenon is total absorption spectroscopy, thanks to which one can measure the B(GT) distribution in beta-decay experiments even when it is very fragmented and lies at high excitation energy in the daughter nucleus. Results on the GT resonance measured in the beta decay of the odd-Z, N = 83 nuclei Tb-148, Ho-150, and Tm-152 are presented in this work and compared with shell-model calculations. The tail of the resonance is clearly observed up to the limit imposed by the Q value. This observation is important in the context of the understanding of the “quenching” of the GT strength.
|
|
|
Olleros, P., Caballero, L., Domingo-Pardo, C., Babiano, V., Ladarescu, I., Calvo, D., et al. (2018). On the performance of large monolithic LaCl3(Ce) crystals coupled to pixelated silicon photosensors. J. Instrum., 13, P03014–17pp.
Abstract: We investigate the performance of large area radiation detectors, with high energy-and spatial-resolution, intended for the development of a Total Energy Detector with gamma-ray imaging capability, so-called i-TED. This new development aims for an enhancement in detection sensitivity in time-of-flight neutron capture measurements, versus the commonly used C6D6 liquid scintillation total-energy detectors. In this work, we study in detail the impact of the readout photosensor on the energy response of large area (50 x 50 mm(2)) monolithic LaCl3(Ce) crystals, in particular when replacing a conventional mono-cathode photomultiplier tube by an 8 x 8 pixelated silicon photomultiplier. Using the largest commercially available monolithic SiPM array (25 cm(2)), with a pixel size of 6 x 6 mm(2), we have measured an average energy resolution of 3.92% FWHM at 662 keV for crystal thick-nesses of 10, 20 and 30 mm. The results are confronted with detailed Monte Carlo (MC) calculations, where optical processes and properties have been included for the reliable tracking of the scintillation photons. After the experimental validation of the MC model, we use our MC code to explore the impact of a smaller photosensor segmentation on the energy resolution. Our optical MC simulations predict only a marginal deterioration of the spectroscopic performance for pixels of 3 x 3 mm(2).
|
|
|
Cabanelas, P. et al, & Nacher, E. (2020). Performance recovery of long CsI(Tl) scintillator crystals with APD-based readout. Nucl. Instrum. Methods Phys. Res. A, 965, 163845–6pp.
Abstract: CALIFA is the high efficiency and energy resolution calorimeter for the (RB)-B-3 experiment at FAIR, intended for detecting high energy light charged particles and gamma rays in scattering experiments, and is being commissioned during the Phase-0 experiments at FAIR, between 2018 and 2020. It surrounds the reaction target in a segmented configuration with 2432 detection units made of long CsI(Tl) finger-shaped scintillator crystals. CALIFA has a 10 year intended operational lifetime as the (RB)-B-3 calorimeter, necessitating measures to be taken to ensure enduring performance. In this paper we present a systematic study of two groups of 6 different detection units of the CALIFA detector after more than four years of operation. The energy resolution and light output yield are evaluated under different conditions. Tests cover the aging of the first detector units assembled and investigates recovery procedures for degraded detection units. A possible reason for the observed degradation is given, pointing to the crystal-APD coupling.
|
|
|
Jungclaus, A., Doornenbal, P., Acosta, J., Vaquero, V., Browne, F., Cortes, M. L., et al. (2024). Position of the single-particle 3/2- state in 135Sn and the N = 90 subshell closure. Phys. Lett. B, 851, 138561–5pp.
Abstract: The decay of excited states of the nucleus Sn-135, with three neutrons outside the doubly-magic Sn-132 core, was studied in an experiment performed at the Radioactive Isotope Beam Factory at RIKEN. Several gamma rays emitted from excited Sn-135 ions were observed following one-neutron and one-neutron-one-proton removal from Sn-136 and Sb-137 beams, respectively, on a beryllium target at relativistic energies. Based on the analogy to 133Sn populated via one-neutron removal from Sn-134, an excitation energy of 695(15) keV is assigned to the 3/2(-) state with strongest single-particle character in 135Sn. This result provides the first direct information about the evolution of the neutron shell structure beyond N = 82 and thus allows for a crucial test of shellmodel calculations in this region. The experimental findings are in full agreement with calculations performed employing microscopic effective two-body interactions derived from CD-Bonn and N3LO nucleon-nucleon potentials, which do not predict a pronounced subshell gap at neutron number N=90. The occurrence of such a gap in Sn-140, i.e., when the 1f(7/2) orbital is completely filled, had been proposed in the past, in analogy to the magicity of Ca-48, featuring a completely filled 0f(7/2) orbital one harmonic oscillator shell below.
|
|
|
Briz, J. A., Nerio, A. N., Ballesteros, C., Borge, M. J. G., Martinez, P., Perea, A., et al. (2022). Proton Radiographs Using Position-Sensitive Silicon Detectors and High-Resolution Scintillators. IEEE Trans. Nucl. Sci., 69(4), 696–702.
Abstract: Proton therapy is a cancer treatment technique currently in growth since it offers advantages with respect to conventional X-ray and gamma-ray radiotherapy. In particular, better control of the dose deposition allowing to reach higher conformity in the treatments causing less secondary effects. However, in order to take full advantage of its potential, improvements in treatment planning and dose verification are required. A new prototype of proton computed tomography scanner is proposed to design more accurate and precise treatment plans for proton therapy. Our prototype is formed by double-sided silicon strip detectors and scintillators of LaBr3(Ce) with high energy resolution and fast response. Here, the results obtained from an experiment performed using a 100-MeV proton beam are presented. Proton radiographs of polymethyl methacrylate (PMMA) samples of 50-mm thickness with spatial patterns in aluminum were taken. Their properties were studied, including reproduction of the dimensions, spatial resolution, and sensitivity to different materials. Structures of up to 2 mm are well resolved and the sensitivity of the system was enough to distinguish the thicknesses of 10 mm of aluminum or PMMA. The spatial resolution of the images was 0.3 line pairs per mm (MTF-10%). This constitutes the first step to validate the device as a proton radiography scanner.
|
|