|
Labiche, M. et al, Caballero, L., & Rubio, B. (2010). TIARA: A large solid angle silicon array for direct reaction studies with radioactive beams. Nucl. Instrum. Methods Phys. Res. A, 614(3), 439–448.
Abstract: A compact, quasi-4 pi position sensitive silicon array. TIARA, designed to study direct reactions induced by radioactive beams in inverse kinematics is described here. The Transfer and Inelastic All-angle Reaction Array (TIARA) consists of 8 resistive charge division detectors forming an octagonal barrel around the target and a set of double-sided silicon-strip annular detectors positioned at each end of the barrel. The detector was coupled to the gamma-ray array EXOGAM and the spectrometer VAMOS at the GANIL Laboratory to demonstrate the potential of such an apparatus with radioactive beams. The N-14(d,p)N-15 reaction, well known in direct kinematics, has been carried out in inverse kinematics for that purpose. The observation of the N-15 ground state and excited states at 7.16 and 7.86 MeV is presented here as well as the comparison of the measured proton angular distributions with DWBA calculations. Transferred l-values are in very good agreement with both theoretical calculations and previous experimental results obtained in direct kinematics.
|
|
|
n_TOF Collaboration(Tagliente, G. et al.), Domingo-Pardo, C., & Tain, J. L. (2010). The Zr-92(n,gamma) reaction and its implications for stellar nucleosynthesis. Phys. Rev. C, 81(5), 055801–9pp.
Abstract: Because the relatively small neutron capture cross sections of the zirconium isotopes are difficult to measure, the results of previous measurements are often not adequate for a number of problems in astrophysics and nuclear technology. Therefore, the Zr-92(n,gamma) cross section has been remeasured at the CERN n_TOF facility, providing a set of improved parameters for 44 resonances in the neutron energy range up to 40 keV. With this information the cross-section uncertainties in the keV region could be reduced to 5% as required for s-process nucleosynthesis studies and technological applications.
|
|
|
Warnecke, S., Sevryuk, M. B., Ceperley, D. M., Toennies, J. P., Guardiola, R., & Navarro, J. (2010). The structure of para-hydrogen clusters. Eur. Phys. J. D, 56(3), 353–358.
Abstract: The path integral Monte Carlo calculated radial distributions of para-hydrogen clusters (p-H-2) N consisting of N = 4-40 molecules interacting via a Lennard-Jones potential at T = 1.5 K show evidence for additional peaks compared to radial distributions calculated by diffusion Monte Carlo (T = 0 K) and path integral Monte Carlo at T <= 0.5 K. The difference in structures is attributed to quantum delocalization at the lowest temperature. The new structures at finite temperatures appear to be consistent with classical structures calculated for an effective Morse potential, which in order to account for the large zero point energy, is substantially softer than the Lennard-Jones potential.
|
|
|
Cabello, J., & Wells, K. (2010). The spatial resolution of silicon-based electron detectors in beta-autoradiography. Phys. Med. Biol., 55(6), 1677–1699.
Abstract: Thin tissue autoradiography is an imaging modality where ex-vivo tissue sections are placed in direct contact with autoradiographic film. These tissue sections contain a radiolabelled ligand bound to a specific biomolecule under study. This radioligand emits beta- or beta+ particles ionizing silver halide crystals in the film. High spatial resolution autoradiograms are obtained using low energy radioisotopes, such as H-3 where an intrinsic 0.1-1 μm spatial resolution can be achieved. Several digital alternatives have been presented over the past few years to replace conventional film but their spatial resolution has yet to equal film, although silicon-based imaging technologies have demonstrated higher sensitivity compared to conventional film. It will be shown in this work how pixel size is a critical parameter for achieving high spatial resolution for low energy uncollimated beta imaging. In this work we also examine the confounding factors impeding silicon-based technologies with respect to spatial resolution. The study considers charge diffusion in silicon and detector noise, and this is applied to a range of radioisotopes typically used in autoradiography. Finally an optimal detector geometry to obtain the best possible spatial resolution for a specific technology and a specific radioisotope is suggested.
|
|
|
Noguera, S., & Vento, V. (2010). The pion transition form factor and the pion distribution amplitude. Eur. Phys. J. A, 46(2), 197–205.
Abstract: Recent BaBar data on the pion transition form factor, whose Q(2)-dependence is much steeper then predicted by asymptotic Quantum Chromodynamics (QCD), have caused a renewed interest in its theoretical description. We present here a formalism based on a model-independent description for low photon virtuality and a high photon virtuality description based on QCD, which match at a scale Q(0). The high photon virtuality description incorporates a flat pion distribution amplitude, phi(x) = 1, at the matching scale Q(0) and QCD evolution from Q(0) to Q > Q(0). The flat pion distribution is connected, through soft pion theorems and chiral symmetry, to the pion valence parton distribution at the same low scale Q(0). The procedure leads to a good description of the data, and by incorporating additional twist-three effects, to an excellent description of the data.
|
|