|
LHCb Collaboration(Aaij, R. et al), Martinez-Vidal, F., Oyanguren, A., Ruiz Valls, P., & Sanchez Mayordomo, C. (2014). Precision Measurement of the Mass and Lifetime of the Xi(-)(b) Baryon. Phys. Rev. Lett., 113(24), 242002–9pp.
Abstract: We report on measurements of the mass and lifetime of the Xi(-)(b) baryon using about 1800 Xi(-)(b) decays reconstructed in a proton-proton collision data set corresponding to an integrated luminosity of 3.0 fb(-1) collected by the LHCb experiment. The decays are reconstructed in the Xi(-)(b) -> Xi(0)(c)pi(-), Xi(0)(c) -> pK(-)K(-)pi(+) channel and the mass and lifetime are measured using the Lambda(0)(b) -> Lambda(+)(c)pi(-) mode as a reference. We measure M(Xi(-)(b)) – M(Lambda(0)(b)) = 178.36 +/- 0.46 +/- 0.16 MeV/c(2), (tau Xi(-)(b)/tau Lambda(0)(b)) = 1.089 +/- 0.026 +/- 0.011, where the uncertainties are statistical and systematic, respectively. These results lead to a factor of 2 better precision on the Xi(-)(b) mass and lifetime compared to previous best measurements, and are consistent with theoretical expectations.
|
|
|
LHCb Collaboration(Aaij, R. et al), Garcia Martin, L. M., Henry, L., Jashal, B. K., Martinez-Vidal, F., Oyanguren, A., et al. (2019). Precision measurement of the Lambda(+)(c), Xi(+)(c), and Xi(0)(c) baryon lifetimes. Phys. Rev. D, 100(3), 032001–12pp.
Abstract: We report measurements of the lifetimes of the Lambda(+)(c), Xi(+)(c) and Xi(0)(c) charm baryons using proton- proton collision data at center- of- mass energies of 7 and 8 TeV, corresponding to an integrated luminosity of 3.0 fb(-1), collected by the LHCb experiment. The charm baryons are reconstructed through the decays Lambda(+)(c) -> pK(-)pi(+),. Xi(+)(c) -> pK(-) pi(+) and Xi(0)(c) -> pK(-) K- pi(+), and originate from semimuonic decays of beauty baryons. The lifetimes are measured relative to that of the D+ meson, and are determined to be tau Lambda(+)(c) = 203.5 +/- 1.0 +/- 1.3 +/- 1.4 fs; tau Xi(+)(c) = 456.8 +/- 3.5 +/- 2.9 +/- 3.1 fs; tau Xi(0)(c) = 154.5 +/- 1.7 +/- 1.6 +/- 1.0 fs; where the uncertainties are statistical, systematic, and due to the uncertainty in the D+ lifetime. The measurements are approximately 3- 4 times more precise than the current world average values. The. +c and Xi(+)(c) lifetimes are in agreement with previous measurements; however, the Xi(0)(c) baryon lifetime is approximately 3.3 standard deviations larger than the world average value.
|
|
|
LHCb Collaboration(Aaij, R. et al), Oyanguren, A., & Ruiz Valls, P. (2013). Precision measurement of the B-s(0)-(B)over-bar(s)(0) oscillation frequency with the decay B-s(0) -> D-s(-)pi(+). New J. Phys., 15, 053021–15pp.
Abstract: A key ingredient to searches for physics beyond the Standard Model in B-s(0) mixing phenomena is the measurement of the B-s(0)-(B) over bar (0)(s) oscillation frequency, which is equivalent to the mass difference Delta m(s) of the B-s(0) mass eigenstates. Using the world's largest B-s(0) meson sample accumulated in a dataset, corresponding to an integrated luminosity of 1.0 fb(-1), collected by the LHCb experiment at the CERN LHC in 2011, a measurement of Delta m(s) is presented. A total of about 34 000 B-s(0) -> D-s(-)pi(+) signal decays are reconstructed, with an average decay time resolution of 44 fs. The oscillation frequency is measured to be Delta m(s) = 17.768 +/- 0.023 (stat) +/- 0.006 (syst) ps(-1), which is the most precise measurement to date.
|
|
|
LHCb Collaboration(Aaij, R. et al), Garcia Martin, L. M., Henry, L., Jashal, B. K., Martinez-Vidal, F., Oyanguren, A., et al. (2020). Precision measurement of the B-c(+) meson mass. J. High Energy Phys., 07(7), 123–21pp.
Abstract: A precision measurement of the B-c(+) meson mass is performed using proton- proton collision data collected with the LHCb experiment at centre-of-mass energies of 7, 8 and 13 TeV, corresponding to a total integrated luminosity of 9.0 fb(-1). The B-c(+) mesons are reconstructed via the decays B-c(+)-> J/psi pi(+), B-c(+)-> J/psi pi(+)pi(-)pi(+), B-c(+)-> J/psi pp<overbar>pi(+), B-c(+)-> J/psi D-s(+), B-c(+)-> J/psi (DK+)-K-0 and B-c(+)-> B-s(0)pi(+). Combining the results of the individual decay channels, the B-c(+) mass is measured to be 6274.47 +/- 0.27 (stat) +/- 0.17 (syst) MeV/c(2). This is the most precise measurement of the B-c(+) mass to date. The difference between the B-c(+) and B-s(0) meson masses is measured to be 907.75 +/- 0.37 (stat) +/- 0.27 (syst) MeV/c(2).
|
|
|
LHCb Collaboration(Aaij, R. et al), Jashal, B. K., Martinez-Vidal, F., Oyanguren, A., Remon Alepuz, C., & Ruiz Vidal, J. (2022). Precision measurement of forward Z boson production in proton-proton collisions at root s=13 TeV. J. High Energy Phys., 07(7), 026–57pp.
Abstract: A precision measurement of the Z boson production cross-section at root s = 13 TeV in the forward region is presented, using pp collision data collected by the LHCb detector, corresponding to an integrated luminosity of 5.1 fb(-1). The production cross-section is measured using Z -> mu(+)mu(-) events within the fiducial region defined as pseudorapidity 2.0 < eta < 4.5 and transverse momentum p(T) > 20 GeV/c for both muons and dimuon invariant mass 60 < M-mu μ< 120 GeV/c(2). The integrated cross-section is determined to be sigma(Z -> mu(+)mu(-)) = 196.4 +/- 0.2 +/- 1.6 +/- 3.9 pb, where the first uncertainty is statistical, the second is systematic, and the third is due to the luminosity determination. The measured results are in agreement with theoretical predictions within uncertainties.
|
|