Bonilla, C., Morisi, S., Peinado, E., & Valle, J. W. F. (2015). Relating quarks and leptons with the T-7 flavour group. Phys. Lett. B, 742, 99–106.
Abstract: In this letter we present a model for quarks and leptons based on T-7 as flavour symmetry, predicting a canonical mass relation between charged leptons and down-type quarks proposed earlier. Neutrino masses are generated through a Type-I seesaw mechanism, with predicted correlations between the atmospheric mixing angle and neutrino masses. Compatibility with oscillation results leads to lower bounds for the lightest neutrino mass as well as for the neutrinoless double beta decay rates, even for normal neutrino mass hierarchy.
|
Llosa, G. (2015). Recent developments in photodetection for medical applications. Nucl. Instrum. Methods Phys. Res. A, 787, 353–357.
Abstract: The use of the most advanced technology in medical imaging results in the development of high performance detectors that can significantly improve the performance of the medical devices employed in hospitals. Scintillator crystals coupled to photodetectors remain to be essential detectors in terms of performance and cost for medical imaging applications in different imaging modalities. Recent advances in photodetectors result in an increase of the performance of the medical scanners. Solid state detectors can provide substantial performance improvement, but are more complex to integrate into clinical detectors due mainly to their higher cost. Solid state photodetectors (APDs, SiPMs) have made new detector concepts possible and have led to improvements in different imaging modalities. Recent advances in detectors for medical imaging are revised.
|
Martinez Torres, A., Oset, E., Prelovsek, S., & Ramos, A. (2015). Reanalysis of lattice QCD spectra leading to the Ds0*(2317) and Ds1*(2460). J. High Energy Phys., 05(5), 153–22pp.
Abstract: We perform a reanalysis of the energy levels obtained in a recent lattice QCD simulation, from where the existence of bound states of KD and KD* are induced and identified with the narrow D-s0*(2317) and D-s1*(2460) resonances. The reanalysis is done in terms of an auxiliary potential, employing a single-channel basis KD(*()), and a two-channel basis KD(*()), eta D-s(()*()). By means of an extended Luscher method we determine poles of the continuum t-matrix, bound by about 40 MeV with respect to the KD and KD* thresholds, which we identify with the D-s0*(2317) and D-s1*(2460) resonances. Using a sum rule that reformulates Weinberg compositeness condition we can determine that the state D-s0*(2317) contains a KD component in an amount of about 70%, while the state D-s1*(2460) contains a similar amount of KD*. We argue that the present lattice simulation results do not still allow us to determine which are the missing channels in the bound state wave functions and we discuss the necessary information that can lead to answer this question.
|
NEXT Collaboration(Cebrian, S. et al), Alvarez, V., Carcel, S., Cervera-Villanueva, A., Diaz, J., Ferrario, P., et al. (2015). Radiopurity assessment of the tracking readout for the NEXT double beta decay experiment. J. Instrum., 10, P05006–16pp.
Abstract: The “Neutrino Experiment with a Xenon Time-Projection Chamber” (NEXT) is intended to investigate the neutrinoless double beta decay of Xe-136, which requires a severe suppression of potential backgrounds; therefore, an extensive screening and selection process is underway to control the radiopurity levels of the materials to be used in the experimental set-up of NEXT. The detector design combines the measurement of the topological signature of the event for background discrimination with the energy resolution optimization. Separate energy and tracking readout planes are based on different sensors: photomultiplier tubes for calorimetry and silicon multi-pixel photon counters for tracking. The design of a radiopure tracking plane, in direct contact with the gas detector medium, was specially challenging since the needed components like printed circuit boards, connectors, sensors or capacitors have typically, according to available information in databases and in the literature, activities too large for experiments requiring ultra-low background conditions. Here, the radiopurity assessment of tracking readout components based on gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterraneo de Canfranc (Spain) is described. According to the obtained results, radiopure enough printed circuit boards made of kapton and copper, silicon photomultipliers and other required components, fulfilling the requirement of an overall background level in the region of interest of at most 8 x 10(-4) counts keV(-1) kg(-1) y(-1), have been identified.
|
Boiron, D., Fabbri, A., Larre, P. E., Pavloff, N., Westbrook, C. I., & Zin, P. (2015). Quantum Signature of Analog Hawking Radiation in Momentum Space. Phys. Rev. Lett., 115(2), 025301–5pp.
Abstract: We consider a sonic analog of a black hole realized in the one-dimensional flow of a Bose-Einstein condensate. Our theoretical analysis demonstrates that one-and two-body momentum distributions accessible by present-day experimental techniques provide clear direct evidence (i) of the occurrence of a sonic horizon, (ii) of the associated acoustic Hawking radiation, and (iii) of the quantum nature of the Hawking process. The signature of the quantum behavior persists even at temperatures larger than the chemical potential.
|