Phong, V. H. et al, Agramunt, J., Algora, A., Domingo-Pardo, C., Morales, A. I., Tain, J. L., et al. (2019). Observation of a μs isomer in In-134(49)85: Proton-neutron coupling “southeast” of Sn-132(50)82. Phys. Rev. C, 100(1), 011302–6pp.
Abstract: We report on the observation of a microsecond isomeric state in the single-proton-hole, three-neutron-particle nucleus In-134. The nuclei of interest were produced by in-flight fission of a U-238 beam at the Radioactive Isotope Beam Factory at RIKEN. The isomer depopulates through a gamma ray of energy 56.7(1) keV and with a half-life of T-1/2 = 3.5(4) μs. Based on the comparison with shell-model calculations, we interpret the isomer as the I-pi = 5(-) member of the pi 0g(9/2)(-1) circle times nu 1f(7/2)(3) multiplet, decaying to the I-pi = 7(-) ground state with a reduced-transition probability of B(E2; 5(-) -> 7(-)) = 0.53(6) W.u. Observation of this isomer, and lack of evidence in the current work for a I-pi = 5(-) isomer decay in In-132, provides a benchmark of the proton-neutron interaction in the region of the nuclear chart “southeast” of Sn-132, where experimental information on excited states is sparse.
|
Nacher, E., Rubio, B., Algora, A., Cano-Ott, D., Tain, J. L., Gadea, A., et al. (2016). Observations of the Gamow-Teller resonance in the rare-earth nuclei above Gd-146 populated in beta decay. Phys. Rev. C, 93(1), 014308–13pp.
Abstract: The rare-earth region of the nuclear table around the quasi-doubly magic nucleus Gd-146 is one of the very few places in which the Gamow-Teller (GT) resonance can be populated in beta decay. The appropriate technique to study such a phenomenon is total absorption spectroscopy, thanks to which one can measure the B(GT) distribution in beta-decay experiments even when it is very fragmented and lies at high excitation energy in the daughter nucleus. Results on the GT resonance measured in the beta decay of the odd-Z, N = 83 nuclei Tb-148, Ho-150, and Tm-152 are presented in this work and compared with shell-model calculations. The tail of the resonance is clearly observed up to the limit imposed by the Q value. This observation is important in the context of the understanding of the “quenching” of the GT strength.
|
Mach, H., Lindroth, A., Ruchowska, E., Kvasil, J., Fogelberg, B., Gulda, K., et al. (2016). On the enhanced E1 transitions in the K=3/2 parity doublet band in Ra-223. Eur. Phys. J. A, 52(6), 172–10pp.
Abstract: We have applied the fast timing beta gamma gamma(t) technique to remeasure lifetimes of selected states in Ra-223 populated in the beta(-) decay of Fr-223. T-1/2 = 587(12) ps and 210(13) ps have been obtained for the 3/2(-) and 5/2(-) states at 50.1 and 79.7 keV, that are more accurate than the previous values of 630(70) ps and 166(55) ps, respectively. Our vertical bar D0 vertical bar value of 0.155(10) e.fm obtained for the K = 3/2 configuration together with the available values of vertical bar D0 vertical bar for the K = 1/2 and K = 5/2 parity doublet bands establish the configuration dependence of vertical bar D0 vertical bar at low spins in this nucleus. Results of theoretical calculations performed for Ra-223, using the quasiparticle-phonon model (QPM) with inclusion of the Coriolis coupling, reasonably well reproduce octupole correlations in this nucleus.
|
Olleros, P., Caballero, L., Domingo-Pardo, C., Babiano, V., Ladarescu, I., Calvo, D., et al. (2018). On the performance of large monolithic LaCl3(Ce) crystals coupled to pixelated silicon photosensors. J. Instrum., 13, P03014–17pp.
Abstract: We investigate the performance of large area radiation detectors, with high energy-and spatial-resolution, intended for the development of a Total Energy Detector with gamma-ray imaging capability, so-called i-TED. This new development aims for an enhancement in detection sensitivity in time-of-flight neutron capture measurements, versus the commonly used C6D6 liquid scintillation total-energy detectors. In this work, we study in detail the impact of the readout photosensor on the energy response of large area (50 x 50 mm(2)) monolithic LaCl3(Ce) crystals, in particular when replacing a conventional mono-cathode photomultiplier tube by an 8 x 8 pixelated silicon photomultiplier. Using the largest commercially available monolithic SiPM array (25 cm(2)), with a pixel size of 6 x 6 mm(2), we have measured an average energy resolution of 3.92% FWHM at 662 keV for crystal thick-nesses of 10, 20 and 30 mm. The results are confronted with detailed Monte Carlo (MC) calculations, where optical processes and properties have been included for the reliable tracking of the scintillation photons. After the experimental validation of the MC model, we use our MC code to explore the impact of a smaller photosensor segmentation on the energy resolution. Our optical MC simulations predict only a marginal deterioration of the spectroscopic performance for pixels of 3 x 3 mm(2).
|
n_TOF Collaboration(Chiaveri, E. et al), Giubrone, G., & Tain, J. L. (2011). Past, Present and Future of the n_TOF Facility at CERN. J. Korean Phys. Soc., 59(2), 1620–1623.
Abstract: The nTOF spallation neutron facility is operating at CERN since 2001. Neutrons are produced with a very wide energy range, from thermal up to 1 GeV and with a very high instantaneous flux (10(5)n/cm(2)/pulse at 200 m from target) thanks to the high intensity (7 x 10(12) protons/pulse) and low repetition rate of the Proton Synchrotron (PS) which is delivering protons to a lead spallation target. The experimental area is located at 200 m from the target, resulting in a very good energy resolution and beam quality thanks to the adoption of an optimal collimation system. At the end of 2008 the nTOF facility has resumed operation after a halt of 3 years due to technical issues. This contribution will outline the main physics results obtained by the facility since its inception in 1999, and show the importance of the measured nuclear data in the field of Nuclear Astrophysics and Nuclear Technology. Then it will present the future perspectives of the facility, aiming mainly in the direction of measuring highly radioactive samples, for which the facility has unique capabilities, with a lower background.
|