Belle-II DEPFET and PXD Collaborations(Wang, B. et al), & Marinas, C. (2022). Operational experience of the Belle II pixel detector. Nucl. Instrum. Methods Phys. Res. A, 1032, 166631–7pp.
Abstract: The Belle II experiment at the SuperKEKB accelerator has started its physics data taking with the full detector setup in March 2019. It aims to collect 40 times more e+e- collision data compared with its predecessor Belle experiment. The Belle II pixel detector (PXD) is based on the Depleted P-channel Field Effect Transistor (DEPFET) technology. The PXD plays an important role in the tracking and vertexing of the Belle II detector. Its two layers are arranged at radii of 14 mm and 22 mm around the interaction point. The sensors are thinned down to 75 μm to minimize multiple scattering, and each module has interconnects and ASICs integrated on the sensor with silicon frames for mechanical support. PXD showed good performance during data taking. It also faces several operational challenges due to the high background level from the SuperKEKB accelerator, such as the damage from beam loss events, the drift in the HV working point due to radiation effect, and the impact of the high background.
|
|
|
Wieduwilt, P., Paschen, B., Schreeck, H., Schwenker, B., Soltau, J., Ahlburg, P., et al. (2021). Performance of production modules of the Belle II pixel detector in a high-energy particle beam. Nucl. Instrum. Methods Phys. Res. A, 991, 164978–15pp.
Abstract: The Belle II experiment at the Super B factory SuperKEKB, an asymmetric e(+) e(-) collider located in Tsukuba, Japan, is tailored to perform precision B physics measurements. The centre of mass energy of the collisions is equal to the rest mass of the gamma (4S) resonance of m(gamma(4S)) = 10.58 GeV. A high vertex resolution is essential for measuring the decay vertices of B mesons. Typical momenta of the decay products are ranging from a few tens of MeV to a few GeV and multiple scattering has a significant impact on the vertex resolution. The VerteX Detector (VXD) for Belle II is therefore designed to have as little material as possible inside the acceptance region. Especially the innermost two layers, populated by the PiXel Detector (PXD), have to be ultra-thin. The PXD is based on DEpleted P-channel Field Effect Transistors (DEPFETs) with a thickness of only 75 μm. Spatial resolution and hit efficiency of production detector modules were studied in beam tests performed at the DESY test beam facility. The spatial resolution was investigated as a function of the incidence angle and improvements due to charge sharing are demonstrated. The measured module performance is compatible with the requirements for Belle II.
|
|
|
Boronat, M., Marinas, C., Frey, A., Garcia, I., Schwenker, B., Vos, M., et al. (2015). Physical Limitations to the Spatial Resolution of Solid-State Detectors. IEEE Trans. Nucl. Sci., 62(1), 381–386.
Abstract: In this paper we explore the effect of delta-ray emission and fluctuations in the signal deposition on the detection of charged particles in silicon-based detectors. We show that these two effects ultimately limit the resolution that can be achieved by interpolation of the signal in finely segmented position-sensitive solid-state devices.
|
|
|
Belle II Collaboration(Abudinen, F. et al), & Marinas, C. (2021). Precise Measurement of the D-0 and D+ Lifetimes at Belle II. Phys. Rev. Lett., 127(21), 211801–9pp.
Abstract: We report a measurement of the D-0 and D+ lifetimes using D-0 -> K-pi(+) and D+ -> K-pi(+)pi(+) decays reconstructed in e(+)e(-) -> c (c) over bar data recorded by the Belle II experiment at the SuperKEKB asymmetric-energy e(+)e(-) collider. The data, collected at center-of-mass energies at or near the (sic)(4S) resonance, correspond to an integrated luminosity of 72 fb(-1). The results, (tau)(D-0) = 410.5 +/- 1.1 (stat) +/- 0.8(syst) fs and tau(D-0) = 1030.4 +/- 4.7 (stat) +/- 3.1 (syst) fs, are the most precise to date and are consistent with previous determinations.
|
|
|
Belle II Collaboration(Adachi, I. et al), Gomis, P., & Marinas, C. (2020). Search for an Invisibly Decaying Z ' Boson at Belle II in e(+)e(-) -> mu(+)mu(-) (e(+/-)mu(-/+)) Plus Missing Energy Final States. Phys. Rev. Lett., 124(14), 141801–9pp.
Abstract: Theories beyond the standard model often predict the existence of an additional neutral boson, the Z'. Using data collected by the Belle II experiment during 2018 at the SuperKEKB collider, we perform the first searches for the invisible decay of a Z' in the process e(+)e(-) -> mu(+)mu(-) Z' and of a lepton-flavor-violating Z' in e(+) e(-) -> e(+/-)mu(-/+)Z'. We do not find any excess of events and set 90% credibility level upper limits on the cross sections of these processes. We translate the former, in the framework of an L, – L, theory, into upper limits on the Z' coupling constant at the level of 5 x 10(-2) – 1 for M-z' <= 6 GeV/c(2).
|
|
|
Belle II Collaboration(Abudinen, F. et al), Gomis, P., & Marinas, C. (2020). Search for Axionlike Particles Produced in e(+)e(-) Collisions at Belle II. Phys. Rev. Lett., 125(16), 161806–9pp.
Abstract: We present a search for the direct production of a light pseudoscalar a decaying into two photons with the Belle II detector at the SuperKEKB collider. We search for the process e(+)e(-) -> gamma a, a -> gamma gamma in the mass range 0.2 < m(a) < 9.7 GeV/c(2) using data corresponding to an integrated luminosity of (445 +/- 3) pb(-1). Light pseudoscalars interacting predominantly with standard model gauge bosons (so-called axionlike particles or ALPs) are frequently postulated in extensions of the standard model. We find no evidence for ALPs and set 95% confidence level upper limits on the coupling strength g(a gamma gamma) of ALPs to photons at the level of 10(-3) GeV-1. The limits are the most restrictive to date for 0.2 < m(a) < 1 GeV/c(2).
|
|
|
Belle II Collaboration(Abudinen, F. et al), & Marinas, C. (2021). Search for B+ -> K+nu(nu)over-bar Decays Using an Inclusive Tagging Method at Belle H. Phys. Rev. Lett., 127(18), 181802–10pp.
Abstract: A search for the flavor-changing neutral-current decay B+ -> K+nu(nu) over bar is performed at the Belle II experiment at the SuperKEKB asymmetric energy electron-positron collider. The data sample corresponds to an integrated luminosity of 63 fb(-1) collected at the Upsilon(4S) resonance and a sample of 9 fb(-1) collected at an energy 60 MeV below the resonance. Because the measurable decay signature involves only a single charged kaon, a novel measurement approach is used that exploits not only the properties of the B+ -> K+nu(nu) over bar decay, but also the inclusive properties of the other B meson in the Upsilon(4S) -> B (B) over bar event, to suppress the background from other B meson decays and light-quark pair production. This inclusive tagging approach offers a higher signal efficiency compared to previous searches. No significant signal is observed. An upper limit on the branching fraction of B+ -> K+nu(nu) over bar of 4.1 x 10(-5) is set at the 90% confidence level.
|
|
|
Marinas, C., & Vos, M. (2011). The Belle-II DEPFET pixel detector: A step forward in vertexing in the superKEKB flavour factory. Nucl. Instrum. Methods Phys. Res. A, 650(1), 59–63.
Abstract: An upgrade of the successful asymmetric e(+)e(-) collider in KEK (Tsukuba, Japan) is foreseen by the fall of 2013. This new Super Flavor Factory will deliver an increased instantaneous luminosity of up to L = 8 x 10(35) cm(-2) s(-1), 40 times larger than the current KEKB machine. To exploit these new conditions and provide high precision measurements of the decay vertex of the B meson systems, a new silicon vertex detector will be operated in Belle. This new detector will consist of two layers of DEPFET Active Pixel Sensors as close as possible to the interaction point. DEPFET is a field effect transistor, with an additional deep implant underneath the channel's gate, integrated on a completely depleted bulk. This technology offers detection and an in-pixel amplification stage, while keeping low the power consumption. Under these conditions, thin sensors with small pixel size and low intrinsic noise are possible. In this article, an overview of the full system will be described, including the sensor, the front-end electronics and both the mechanical and thermal proposed solutions as well as the expected performance.
|
|