ATLAS Collaboration(Aad, G. et al), Amoros, G., Cabrera Urban, S., Castillo Gimenez, V., Costa, M. J., Escobar, C., et al. (2011). Search for massive long-lived highly ionising particles with the ATLAS detector at the LHC. Phys. Lett. B, 698(5), 353–370.
Abstract: A search is made for massive highly ionising particles with lifetimes in excess of 100 ns, with the ATLAS experiment at the Large Hadron Collider, using 3.1 pb(-1) of pp collision data taken at root s = 7 TeV. The signature of energy loss in the ATLAS inner detector and electromagnetic calorimeter is used. No such particles are found and limits on the production cross section for electric charges 6e <= vertical bar q vertical bar <= 17e and masses 200 GeV <= m <= 1000 GeV are set in the range 1-12 pb for different hypotheses on the production mechanism.
|
Trotta, R., Johannesson, G., Moskalenko, I. V., Porter, T. A., Ruiz de Austri, R., & Strong, A. W. (2011). Constraints on Cosmic-Ray Propagation Models from a Global Bayesian Analysis. Astrophys. J., 729(2), 106–16pp.
Abstract: Research in many areas of modern physics such as, e. g., indirect searches for dark matter and particle acceleration in supernova remnant shocks rely heavily on studies of cosmic rays (CRs) and associated diffuse emissions (radio, microwave, X-rays, gamma-rays). While very detailed numerical models of CR propagation exist, a quantitative statistical analysis of such models has been so far hampered by the large computational effort that those models require. Although statistical analyses have been carried out before using semi-analytical models (where the computation is much faster), the evaluation of the results obtained from such models is difficult, as they necessarily suffer from many simplifying assumptions. The main objective of this paper is to present a working method for a full Bayesian parameter estimation for a numerical CR propagation model. For this study, we use the GALPROP code, the most advanced of its kind, which uses astrophysical information, and nuclear and particle data as inputs to self-consistently predict CRs, gamma-rays, synchrotron, and other observables. We demonstrate that a full Bayesian analysis is possible using nested sampling and Markov Chain Monte Carlo methods (implemented in the SuperBayeS code) despite the heavy computational demands of a numerical propagation code. The best-fit values of parameters found in this analysis are in agreement with previous, significantly simpler, studies also based on GALPROP.
|
Montanari, D. et al, & Gadea, A. (2011). Probing the nature of particle-core couplings in Ca-49 with gamma spectroscopy and heavy-ion transfer reactions. Phys. Lett. B, 697(4), 288–293.
Abstract: Neutron rich nuclei around Ca-48 have been measured with the CLARA-PRISMA setup, making use of Ca-48 on Ni-64 binary reactions, at 5.9 MeV/A. Angular distributions of gamma rays give evidence, in several transfer channels, for a large spin alignment (approximate to 70%) perpendicular to the reaction plane, making it possible to firmly establish spin and parities of the excited states. In the case of Ca-49, states arising from different types of particle-core couplings are, for the first time, unambiguously identified on basis of angular distribution, polarization and lifetime measurements. Shell model and particle-vibration coupling calculations are used to pin down the nature of the states. Evidence is found for the presence, in the same excitation energy region, of two types of coupled states, i.e. single particle coupled to either Ca-48 or Ca-50 simple configurations, and particle-vibration coupled states based on the 3- phonon of Ca-48.
|
Marco-Hernandez, R. (2011). Development of a beam test telescope based on the Alibava readout system. J. Instrum., 6, C01002–7pp.
Abstract: A telescope for a beam test have been developed as a result of a collaboration among the University of Liverpool, Centro Nacional de Microelectronica (CNM) of Barcelona and Instituto de Fisica Corpuscular (IFIC) of Valencia. This system is intended to carry out both analogue charge collection and spatial resolution measurements with different types of microstrip or pixel silicon detectors in a beam test environment. The telescope has four XY measurement as well as trigger planes (XYT board) and it can accommodate up to twelve devices under test (DUT board). The DUT board uses two Beetle ASICs for the readout of chilled silicon detectors. The board could operate in a self-triggering mode. The board features a temperature sensor and it can be mounted on a rotary stage. A peltier element is used for cooling the DUT. Each XYT board measures the track space points using two silicon strip detectors connected to two Beetle ASICs. It can also trigger on the particle tracks in the beam test. The board includes a CPLD which allows for the synchronization of the trigger signal to a common clock frequency, delaying and implementing coincidence with other XYT boards. An Alibava mother board is used to read out and to control each XYT/DUT board from a common trigger signal and a common clock signal. The Alibava board has a TDC on board to have a time stamp of each trigger. The data collected by each Alibava board is sent to a master card by means of a local data/address bus following a custom digital protocol. The master board distributes the trigger, clock and reset signals. It also merges the data streams from up to sixteen Alibava boards. The board has also a test channel for testing in a standard mode a XYT or DUT board. This board is implemented with a Xilinx development board and a custom patch board. The master board is connected with the DAQ software via 100M Ethernet. Track based alignment software has also been developed for the data obtained with the DAQ software.
|
Pierre Auger Collaboration(Abreu, P. et al), & Pastor, S. (2011). The Pierre Auger Observatory scaler mode for the study of solar activity modulation of galactic cosmic rays. J. Instrum., 6, P01003–16pp.
Abstract: Since data-taking began in January 2004, the Pierre Auger Observatory has been recording the count rates of low energy secondary cosmic ray particles for the self-calibration of the ground detectors of its surface detector array. After correcting for atmospheric effects, modulations of galactic cosmic rays due to solar activity and transient events are observed. Temporal variations related with the activity of the heliosphere can be determined with high accuracy due to the high total count rates. In this study, the available data are presented together with an analysis focused on the observation of Forbush decreases, where a strong correlation with neutron monitor data is found.
|
ATLAS Collaboration(Abat, E. et al), Bernabeu Verdu, J., Castillo Gimenez, V., Costa, M. J., Escobar, C., Ferrer, A., et al. (2010). Combined performance studies for electrons at the 2004 ATLAS combined test-beam. J. Instrum., 5, P11006–68pp.
Abstract: In 2004 at the ATLAS (A Toroidal LHC ApparatuS) combined test beam, one slice of the ATLAS barrel detector (including an Inner Detector set-up and the Liquid Argon calorimeter) was exposed to particles from the H8 SPS beam line at CERN. It was the first occasion to test the combined electron performance of ATLAS. This paper presents results obtained for the momentum measurement p with the Inner Detector and for the performance of the electron measurement with the LAr calorimeter (energy E linearity and resolution) in the presence of a magnetic field in the Inner Detector for momenta ranging from 20 GeV/c to 100 GeV/c. Furthermore the particle identification capabilities of the Transition Radiation Tracker, Bremsstrahlungs-recovery algorithms relying on the LAr calorimeter and results obtained for the E/p ratio and a way how to extract scale parameters will be discussed.
|
Garonna, A., Amaldi, U., Bonomi, R., Campo, D., Degiovanni, A., Garlasche, M., et al. (2010). Cyclinac medical accelerators using pulsed C6+/H-2(+) ion sources. J. Instrum., 5, C09004–19pp.
Abstract: Charged particle therapy, or so-called hadrontherapy, is developing very rapidly. There is large pressure on the scientific community to deliver dedicated accelerators, providing the best possible treatment modalities at the lowest cost. In this context, the Italian research Foundation TERA is developing fast-cycling accelerators, dubbed 'cyclinacs'. These are a combination of a cyclotron (accelerating ions to a fixed initial energy) followed by a high gradient linac boosting the ions energy up to the maximum needed for medical therapy. The linac is powered by many independently controlled klystrons to vary the beam energy from one pulse to the next. This accelerator is best suited to treat moving organs with a 4D multipainting spot scanning technique. A dual proton/carbon ion cyclinac is here presented. It consists of an Electron Beam Ion Source, a superconducting isochronous cyclotron and a high-gradient linac. All these machines are pulsed at high repetition rate (100-400 Hz). The source should deliver both C6+ and H-2(+) ions in short pulses (1.5 μs flat-top) and with sufficient intensity (at least 10(8) fully stripped carbon ions per pulse at 300 Hz). The cyclotron accelerates the ions to 120 MeV/u. It features a compact design (with superconducting coils) and a low power consumption. The linac has a novel C-band high-gradient structure and accelerates the ions to variable energies up to 400 MeV/u. High RF frequencies lead to power consumptions which are much lower than the ones of synchrotrons for the same ion extraction energy. This work is part of a collaboration with the CLIC group, which is working at CERN on high-gradient electron-positron colliders.
|
Amaldi, U., Bonomi, R., Braccini, S., Crescenti, M., Degiovanni, A., Garlasche, M., et al. (2010). Accelerators for hadrontherapy: From Lawrence cyclotrons to linacs. Nucl. Instrum. Methods Phys. Res. A, 620(2-3), 563–577.
Abstract: Hadrontherapy with protons and carbon ions is a fast developing methodology in radiation oncology. The accelerators used and planned for this purpose are reviewed starting from the cyclotrons used in the thirties. As discussed in the first part of this paper, normal and superconducting cyclotrons are still employed, together with synchrotrons, for proton therapy while for carbon ion therapy synchrotrons have been till now the only option. The latest developments concern a superconducting cyclotron for carbon ion therapy, fast-cycling high frequency linacs and 'single room' proton therapy facilities. These issues are discussed in the second part of the paper by underlining the present challenges, in particular the treatment of moving organs.
|
Mendez, V., Amoros, G., Garcia, F., & Salt, J. (2010). Emergent algorithms for replica location and selection in data grid. Futur. Gener. Comp. Syst., 26(7), 934–946.
Abstract: Grid infrastructures for e-Science projects are growing in magnitude terms. Improvements in data Grid replication algorithms may be critical in many of these infrastructures. This paper shows a decentralized replica optimization service, providing a general Emergent Artificial Intelligence (EAI) algorithm for the problem definition. Our aim is to set up a theoretical framework for emergent heuristics in Grid environments. Further, we describe two EAI approaches, the Particle Swarm Optimization PSO-Grid Multiswarm Federation and the Ant Colony Optimization ACO-Grid Asynchronous Colonies Optimization replica optimization algorithms, with some examples. We also present extended results with best performance and scalability features for PSO-Grid Multiswarrn Federation.
|
ATLAS Collaboration(Aad, G. et al), Amoros, G., Cabrera Urban, S., Castillo Gimenez, V., Costa, M. J., Escobar, C., et al. (2010). Charged-particle multiplicities in pp interactions at root s=900 GeV measured with the ATLAS detector at the LHC. Phys. Lett. B, 688(1), 21–42.
Abstract: The first measurements from proton-proton collisions recorded with the ATLAS detector at the LHC are presented. Data were collected in December 2009 using a minimum-bias trigger during collisions at a centre-of-mass energy of 900 GeV. The charged-particle multiplicity, its dependence on transverse momentum and pseudorapidity, and the relationship between mean transverse momentum and charged-particle multiplicity are measured for events with at least one charged particle in the kinematic range vertical bar eta vertical bar < 2.5 and p(T) > 500 MeV. The measurements are compared to Monte Carlo models of proton-proton collisions and to results from other experiments at the same centre-of-mass energy. The charged-particle multiplicity per event and unit of pseudorapidity eta = 0 is measured to be 1.333 +/- 0.003(stat.) +/- 0.040(syst.), which is 5-15% higher than the Monte Carlo models predict.
|