LHCb Collaboration(Aaij, R. et al), Garcia Martin, L. M., Henry, L., Martinez-Vidal, F., Oyanguren, A., Remon Alepuz, C., et al. (2018). Measurement of CP asymmetry in B-s(0) -> (DsK +/-)-K-/+ decays. J. High Energy Phys., 03(3), 059–28pp.
Abstract: We report the measurements of the CP-violating parameters in B-s(0) -> (DsK +/-)-K--/+ decays observed in pp collisions, using a data set corresponding to an integrated luminosity of 3.0 fb(-1) recorded with the LHCb detector. We measure C-f = 0.73 +/- 0.14 +/- 0.05, A(f)(Delta Gamma) = 0.39 +/- 0.28 +/- 0.15, A(<(f)over) (Delta Gamma)(bar>) = 0.31 +/- 0.28 +/- 0.15, S-f = -0.52 +/- 0.20 +/- 0.07, S-(f) over bar = -0.49 +/- 0.20 +/- 0.07, where the uncertainties are statistical and systematic, respectively. These parameters are used together with the world-average value of the B-s(0) mixing phase, -2 beta(s), to obtain a measurement of the CKM angle gamma from B-s(0) -> (DsK +/-)-K--/+ decays, yielding gamma – (128 (+17)(-22))degrees modulo 180 degrees, where the uncertainty contains both statistical and systematic contributions. This corresponds to 3.8 sigma evidence for CP violation in the interference between decay and decay after mixing.
|
Caballero, L., Albiol, F., Corbi Bellot, A., Domingo-Pardo, C., Leganes Nieto, J. L., Agramunt Ros, J., et al. (2018). Gamma-ray imaging system for real-time measurements in nuclear waste characterisation. J. Instrum., 13, P03016–23pp.
Abstract: Acompact, portable and large field-of-viewgamma camera that is able to identify, locate and quantify gamma-ray emitting radioisotopes in real-time has been developed. The device delivers spectroscopic and imaging capabilities that enable its use it in a variety of nuclear waste characterisation scenarios, such as radioactivity monitoring in nuclear power plants and more specifically for the decommissioning of nuclear facilities. The technical development of this apparatus and some examples of its application in field measurements are reported in this article. The performance of the presented gamma-camera is also benchmarked against other conventional techniques.
|
Nygren, D. R., Jones, B. J. P., Lopez-March, N., Mei, Y., Psihas, F., & Renner, J. (2018). Neutrinoless double beta decay with 82SeF6 and direct ion imaging. J. Instrum., 13, P03015–23pp.
Abstract: We present a new neutrinoless double beta decay concept: the high pressure selenium hexafluoride gas time projection chamber. A promising new detection technique is outlined which combines techniques pioneered in high pressure xenon gas, such as topological discrimination, with the high Q-value afforded by the double beta decay isotope Se-82. The lack of free electrons in SeF6 mandates the use of an ion TPC. The microphysics of ion production and drift, which have many nuances, are explored. Background estimates are presented, suggesting that such a detector may achieve background indices of better than 1 count per ton per year in the region of interest at the 100 kg scale, and still better at the ton-scale.
|
Olleros, P., Caballero, L., Domingo-Pardo, C., Babiano, V., Ladarescu, I., Calvo, D., et al. (2018). On the performance of large monolithic LaCl3(Ce) crystals coupled to pixelated silicon photosensors. J. Instrum., 13, P03014–17pp.
Abstract: We investigate the performance of large area radiation detectors, with high energy-and spatial-resolution, intended for the development of a Total Energy Detector with gamma-ray imaging capability, so-called i-TED. This new development aims for an enhancement in detection sensitivity in time-of-flight neutron capture measurements, versus the commonly used C6D6 liquid scintillation total-energy detectors. In this work, we study in detail the impact of the readout photosensor on the energy response of large area (50 x 50 mm(2)) monolithic LaCl3(Ce) crystals, in particular when replacing a conventional mono-cathode photomultiplier tube by an 8 x 8 pixelated silicon photomultiplier. Using the largest commercially available monolithic SiPM array (25 cm(2)), with a pixel size of 6 x 6 mm(2), we have measured an average energy resolution of 3.92% FWHM at 662 keV for crystal thick-nesses of 10, 20 and 30 mm. The results are confronted with detailed Monte Carlo (MC) calculations, where optical processes and properties have been included for the reliable tracking of the scintillation photons. After the experimental validation of the MC model, we use our MC code to explore the impact of a smaller photosensor segmentation on the energy resolution. Our optical MC simulations predict only a marginal deterioration of the spectroscopic performance for pixels of 3 x 3 mm(2).
|
Richard, J. M., Valcarce, A., & Vijande, J. (2018). Few-body quark dynamics for doubly heavy baryons and tetraquarks. Phys. Rev. C, 97(3), 035211–10pp.
Abstract: We discuss the adequate treatment of the three- and four-body dynamics for the quark model picture of double-charm baryons and tetraquarks. We stress that the variational and Born-Oppenheimer approximations give energies very close to the exact ones, while the diquark approximation might be somewhat misleading. The Hall-Post inequalities also provide very useful lower bounds that exclude the possibility of stable tetraquarks for some mass ratios and some color wave functions.
|