Montanari, D. et al, & Gadea, A. (2016). Pair neutron transfer in Ni-60+Sn-116 probed via gamma-particle coincidences. Phys. Rev. C, 93(5), 054623–6pp.
Abstract: We performed a gamma-particle coincidence experiment for the Ni-60 + Sn-116 system to investigate whether the population of the two-neutron pickup channel leading to Ni-62 is mainly concentrated in the ground-state transition, as has been found in a previous work [D. Montanari et al., Phys. Rev. Lett. 113, 052501 (2014)]. The experiment has been performed by employing the PRISMA magnetic spectrometer coupled to the Advanced Gamma Tracking Array (AGATA) demonstrator. The strength distribution of excited states corresponding to the inelastic, one-and two-neutron transfer channels has been extracted. We found that in the two-neutron transfer channel the strength to excited states corresponds to a fraction (less than 24%) of the total, consistent with the previously obtained results that the 2n channel is dominated by the ground-state to ground-state transition.
|
LHCb Collaboration(Aaij, R. et al), Martinez-Vidal, F., Oyanguren, A., Ruiz Valls, P., & Sanchez Mayordomo, C. (2016). Measurement of the properties of the Xi(b)(*0) baryon. J. High Energy Phys., 05(5), 161–19pp.
Abstract: We perform a search for near-threshold I (b) (0) resonances decaying to I (b) (-) pi (+) in a sample of proton-proton collision data corresponding to an integrated luminosity of 3 fb(-1) collected by the LHCb experiment. We observe one resonant state, with the following properties: m(Xi b*0) – m (Xi b-) – m (pi+) = 15.727 +/- 0.068 (stat) +/- 0.023 (syst) MeV/c2, Gamma(Xi b*0) = 0.90 +/- 0.16 (stat) +/- 0.08 (syst) MeV. This confirms the previous observation by the CMS collaboration. The state is consistent with the J (P) = 3/2(+)aEuro integral I (b) (au 0) resonance expected in the quark model. This is the most precise determination of the mass and the first measurement of the natural width of this state. We have also measured the ratio sigma(pp -> Xi b*0 X)B(Xi b*0 -> Xi b-pi+)/sigma(pp -> Xi b- X) = 0.28 +/- 0.03 (stat.) +/- 0.01 (syst).
|
ATLAS Collaboration(Aad, G. et al), Alvarez Piqueras, D., Cabrera Urban, S., Castillo Gimenez, V., Cerda Alberich, L., Costa, M. J., et al. (2016). Reconstruction of hadronic decay products of tau leptons with the ATLAS experiment. Eur. Phys. J. C, 76(5), 295–26pp.
Abstract: This paper presents a new method of reconstructing the individual charged and neutral hadrons in tau decays with the ATLAS detector. The reconstructed hadrons are used to classify the decay mode and to calculate the visible four-momentum of reconstructed tau candidates, significantly improving the resolution with respect to the calibration in the existing tau reconstruction. The performance of the reconstruction algorithm is optimised and evaluated using simulation and validated using samples of Z -> tau tau and Z(-> μmu)+jets events selected from proton-proton collisions at a centre-of-mass energy root s = 8 TeV, corresponding to an integrated luminosity of 5 fb(-1).
|
Etxebeste, A., Barrio, J., Muñoz, E., Oliver, J. F., Solaz, C., & Llosa, G. (2016). 3D position determination in monolithic crystals coupled to SiPMs for PET. Phys. Med. Biol., 61(10), 3914–3934.
Abstract: The interest in using continuous monolithic crystals in positron emission tomography (PET) has grown in the last years. Coupled to silicon photomultipliers (SiPMs), the detector can combine high sensitivity and high resolution, the two main factors to be maximized in a positron emission tomograph. In this work, the position determination capability of a detector comprised of a 12 x 12 x 10 mm(3) LYSO crystal coupled to an 8 x 8-pixel array of SiPMs is evaluated. The 3D interaction position of.-rays is estimated using an analytical model of the light distribution including reflections on the facets of the crystal. Monte Carlo simulations have been performed to evaluate different crystal reflectors and geometries. The method has been characterized and applied to different cases. Intrinsic resolution obtained with the position estimation method used in this work, applied to experimental data, achieves sub-millimetre resolution values. Average resolution over the detector surface for 5 mm thick crystal is similar to 0.9 mm FWHM and similar to 1.2 mm FWHM for 10 mm thick crystal. Depth of interaction resolution is close to 2 mm FWHM in both cases, while the FWTM is similar to 5.3 mm for 5 mm thick crystal and similar to 9.6 mm for 10 mm thick crystal.
|
ANTARES Collaboration(Adrian-Martinez, S. et al), Barrios-Marti, J., Hernandez-Rey, J. J., Sanchez-Losa, A., Tönnis, C., Zornoza, J. D., et al. (2016). The first combined search for neutrino point-sources in the Southern Hemisphere with the ANTARES and IceCube neutrino telescopes. Astrophys. J., 823(1), 65–12pp.
Abstract: We present the results of searches for point-like sources of neutrinos based on the first combined analysis of data from both the ANTARES and IceCube neutrino telescopes. The combination of both detectors, which differ in size and location, forms a window in the southern sky where the sensitivity to point sources improves by up to a factor of 2 compared with individual analyses. Using data recorded by ANTARES from 2007 to 2012, and by IceCube from 2008 to 2011, we search for sources of neutrino emission both across the southern sky and from a preselected list of candidate objects. No significant excess over background has been found in these searches, and flux upper limits for the candidate sources are presented for E-2.5 and E-2 power-law spectra with different energy cut-offs.
|