|
Cervantes-Cota, J. L., de Putter, R., & Linder, E. V. (2010). Induced gravity and the attractor dynamics of dark energy/dark matter. J. Cosmol. Astropart. Phys., 12(12), 019–20pp.
Abstract: Attractor solutions that give dynamical reasons for dark energy to act like the cosmological constant, or behavior close to it, are interesting possibilities to explain cosmic acceleration. Coupling the scalar field to matter or to gravity enlarges the dynamical behavior; we consider both couplings together, which can ameliorate some problems for each individually. Such theories have also been proposed in a Higgs-like fashion to induce gravity and unify dark energy and dark matter origins. We explore restrictions on such theories due to their dynamical behavior compared to observations of the cosmic expansion. Quartic potentials in particular have viable stability properties and asymptotically approach general relativity.
|
|
|
Balbinot, R., Carusotto, I., Fabbri, A., & Recati, A. (2010). Testing Hawking Particle Creation By Black Holes Through Correlation Measurements. Int. J. Mod. Phys. D, 19(14), 2371–2377.
Abstract: Hawking's prediction of thermal radiation by black holes has been shown by Unruh to be expected also in condensed matter systems. We show here that in a black hole-like configuration realized in a BEC this particle-creation does indeed take place and can be unambiguously identified via a characteristic pattern in the density-density correlations. This opens the concrete possibility of the experimental verification of this effect.
|
|
|
Bordes, J., Chan, H. M., & Tsun, T. S. (2010). A solution to the strong CP problem transforming the theta angle to the KM CP-violating phase. Int. J. Mod. Phys. A, 25(32), 5897–5911.
Abstract: It is shown that in the scheme with a rotating fermion mass matrix (i.e. one with a scale-dependent orientation in generation space) suggested earlier for explaining fermion mixing and mass hierarchy, the theta angle term in the QCD action of topological origin can be eliminated by chiral transformations, while giving still nonzero masses to all quarks. Instead, the effects of such transformations get transmitted by the rotation to the CKM matrix as the KM phase giving, for theta of order unity, a Jarlskog invariant typically of order 10(-5), as experimentally observed. Strong and weak CP violations appear then as just two facets of the same phenomenon.
|
|
|
Montanari, D. et al, & Gadea, A. (2011). Probing the nature of particle-core couplings in Ca-49 with gamma spectroscopy and heavy-ion transfer reactions. Phys. Lett. B, 697(4), 288–293.
Abstract: Neutron rich nuclei around Ca-48 have been measured with the CLARA-PRISMA setup, making use of Ca-48 on Ni-64 binary reactions, at 5.9 MeV/A. Angular distributions of gamma rays give evidence, in several transfer channels, for a large spin alignment (approximate to 70%) perpendicular to the reaction plane, making it possible to firmly establish spin and parities of the excited states. In the case of Ca-49, states arising from different types of particle-core couplings are, for the first time, unambiguously identified on basis of angular distribution, polarization and lifetime measurements. Shell model and particle-vibration coupling calculations are used to pin down the nature of the states. Evidence is found for the presence, in the same excitation energy region, of two types of coupled states, i.e. single particle coupled to either Ca-48 or Ca-50 simple configurations, and particle-vibration coupled states based on the 3- phonon of Ca-48.
|
|
|
ATLAS Collaboration(Aad, G. et al), Amoros, G., Cabrera Urban, S., Castillo Gimenez, V., Costa, M. J., Escobar, C., et al. (2011). Measurement of the centrality dependence of J/psi yields and observation of Z production in lead-lead collisions with the ATLAS detector at the LHC. Phys. Lett. B, 697(4), 294–312.
Abstract: Using the ATLAS detector, a centrality-dependent suppression has been observed in the yield of J/psi mesons produced in the collisions of lead ions at the Large Hadron Collider. In a sample of minimum-bias lead-lead collisions at a nucleon-nucleon centre of mass energy root s(NN) = 2.76 TeV, corresponding to an integrated luminosity of about 6.7 μb(-1), J/psi mesons are reconstructed via their decays to mu(+)mu(-) pairs. The measured J/psi yield, normalized to the number of binary nucleon-nucleon collisions, is found to significantly decrease from peripheral to central collisions. The centrality dependence is found to be qualitatively similar to the trends observed at previous, lower energy experiments. The same sample is used to reconstruct Z bosons in the mu(+)mu(-) final state, and a total of 38 candidates are selected in the mass window of 66 to 116 GeV. The relative Z yields as a function of centrality are also presented, although no conclusion can be inferred about their scaling with the number of binary collisions, because of limited statistics. This analysis provides the first results on J/psi and Z production in lead-lead collisions at the LHC.
|
|
|
Meloni, D., Morisi, S., & Peinado, E. (2011). Neutrino phenomenology and stable dark matter with A(4). Phys. Lett. B, 697(4), 339–342.
Abstract: We present a model based on the A(4) non-Abelian discrete symmetry leading to a predictive five-parameter neutrino mass matrix and providing a stable dark matter candidate. We found an interesting correlation among the atmospheric and the reactor angles which predicts theta(23) similar to pi/4for very small reactor angle and deviation from maximal atmospheric mixing for large theta(13). Only normal neutrino mass spectrum is possible and the effective mass entering the neutrinoless double beta decay rate is constrained to be vertical bar m(ee)vertical bar > 4 x 10(-4) eV.
|
|
|
Agarwalla, S. K., Huber, P., Tang, J. A., & Winter, W. (2011). Optimization of the Neutrino Factory, revisited. J. High Energy Phys., 01(1), 120–45pp.
Abstract: We perform the baseline and energy optimization of the Neutrino Factory including the latest simulation results on the magnetized iron detector (MIND). We also consider the impact of tau decays, generated by v(mu) -> v(tau) or v(e) -> v(tau) appearance, on the mass hierarchy, CP violation, and theta(13) discovery reaches, which we find to be negligible for the considered detector. For the baseline-energy optimization for small sin(2) 2 theta(13), we qualitatively recover the results with earlier simulations of the MIND detector. We find optimal baselines of about 2 500km to 5 000km for the CP violation measurement, where now values of E-mu as low as about 12 GeV may be possible. However, for large sin(2) 2 theta(13), we demonstrate that the lower threshold and the backgrounds reconstructed at lower energies allow in fact for muon energies as low as 5 GeV at considerably shorter baselines, such as FNAL-Homestake. This implies that with the latest MIND analysis, low-and high-energy versions of the Neutrino Factory are just two different versions of the same experiment optimized for different parts of the parameter space. Apart from a green-field study of the updated detector performance, we discuss specific implementations for the two-baseline Neutrino Factory, where the considered detector sites are taken to be currently discussed underground laboratories. We find that reasonable setups can be found for the Neutrino Factory source in Asia, Europe, and North America, and that a triangular-shaped storage ring is possible in all cases based on geometrical arguments only.
|
|
|
Valero, A., Castillo Gimenez, V., Ferrer, A., Gonzalez, V., Hernandez Jimenez, Y., Higon-Rodriguez, E., et al. (2011). The ATLAS tile calorimeter ROD injector and multiplexer board. Nucl. Instrum. Methods Phys. Res. A, 629(1), 74–79.
Abstract: The ATLAS Tile Calorimeter is a sampling detector composed by cells made of iron-scintillator tiles. The calorimeter cell signals are digitized in the front-end electronics and transmitted to the Read-Out Drivers (RODs) at the first level trigger rate. The ROD receives triggered data from up to 9856 channels and provides the energy, phase and quality factor of the signals to the second level trigger. The back-end electronics is divided into four partitions containing eight RODs each. Therefore, a total of 32 RODs are used to process and transmit the data of the TileCal detector. In order to emulate the detector signals in the production and commissioning of ROD modules a board called ROD Injector and Multiplexer Board (RIMBO) was designed. In this paper, the RIMBO main functional blocks, PCB design and the different operation modes are described. It is described the crucial role of the board within the TileCal ROD test-bench in order to emulate the front-end electronics during the validation of ROD boards as well as during the evaluation of the ROD signal reconstruction algorithms. Finally, qualification and performance results for the injection operation mode obtained during the Tile Calorimeter ROD production tests are presented.
|
|
|
Mayoral, C., Recati, A., Fabbri, A., Parentani, R., Balbinot, R., & Carusotto, I. (2011). Acoustic white holes in flowing atomic Bose-Einstein condensates. New J. Phys., 13, 025007–29pp.
Abstract: We study acoustic white holes in a steadily flowing atomic Bose-Einstein condensate. A white hole configuration is obtained when the flow velocity goes from a super-sonic value in the upstream region to a sub-sonic one in the downstream region. The scattering of phonon wavepackets on a white hole horizon is numerically studied in terms of the Gross-Pitaevskii equation of mean-field theory: dynamical stability of the acoustic white hole is found, as well as a signature of a nonlinear back-action of the incident phonon wavepacket onto the horizon. The correlation pattern of density fluctuations is numerically studied by means of the truncated-Wigner method, which includes quantum fluctuations. Signatures of the white hole radiation of correlated phonon pairs by the horizon are characterized; analogies and differences with Hawking radiation from acoustic black holes are discussed. In particular, a short wavelength feature is identified in the density correlation function, whose amplitude steadily grows in time since the formation of the horizon. The numerical observations are quantitatively interpreted by means of an analytical Bogoliubov theory of quantum fluctuations for a white hole configuration within the step-like horizon approximation.
|
|
|
Granero, D., Vijande, J., Ballester, F., & Rivard, M. J. (2011). Dosimetry revisited for the HDR Ir-192 brachytherapy source model mHDR-v2. Med. Phys., 38(1), 487–494.
Abstract: Purpose: Recently, the manufacturer of the HDR Ir-192 mHDR-v2 brachytherapy source reported small design changes (referred to herein as mHDR-v2r) that are within the manufacturing tolerances but may alter the existing dosimetric data for this source. This study aimed to (1) check whether these changes affect the existing dosimetric data published for this source; (2) obtain new dosimetric data in close proximity to the source, including the contributions from 192Ir electrons and considering the absence of electronic equilibrium; and (3) obtain scatter dose components for collapsed cone treatment planning system implementation. Methods: Three different Monte Carlo (MC) radiation transport codes were used: MCNP5, PENELOPE2008, and GEANT4. The source was centrally positioned in a 40 cm radius water phantom. Absorbed dose and collision kerma were obtained using 0.1 mm (0.5 mm) thick voxels to provide high-resolution dosimetry near (far from) the source. Dose-rate distributions obtained with the three MC codes were compared. Results: Simulations of mHDR-v2 and mHDR-v2r designs performed with three radiation transport codes showed agreement typically within 0.2% for r >= 0.25 cm. Dosimetric contributions from source electrons were significant for r<0.25 cm. The dose-rate constant and radial dose function were similar to those from previous MC studies of the mHDR-v2 design. The 2D anisotropy function also coincided with that of the mHDR-v2 design for r >= 0.25 cm. Detailed results of dose distributions and scatter components are presented for the modified source design. Conclusions: Comparison of these results to prior MC studies showed agreement typically within 0.5% for r >= 0.25 cm. If dosimetric data for r<0.25 cm are not needed, dosimetric results from the prior MC studies will be adequate. c 2011 American Association of Physicists in Medicine.
|
|