|
Bambi, C., Olmo, G. J., & Rubiera-Garcia, D. (2015). Melvin universe in Born-Infeld gravity. Phys. Rev. D, 91(10), 104010–6pp.
Abstract: We consider a magnetic flux pointing in the z direction of an axially symmetric space-time (Melvin universe) in a Born-Infeld-type extension of general relativity (GR) formulated in the Palatini approach. Large magnetic fields could have been produced in the early Universe, and given rise to interesting phenomenology regarding wormholes and black hole remnants. We find a formal analytic solution to this problem that recovers the GR result in the appropriate limits. Our results set the basis for further extensions that could allow the embedding of pairs of black hole remnants in geometries with intense magnetic fields.
|
|
|
Dai, L. R., Xie, J. J., & Oset, E. (2015). Study of the f(2)(1270), f '(2)(1525), and (K)over-bar(2)*(1430), f(0)(1370) and f(0)(1710) production from psi(nS) and Upsilon(nS) decays. Phys. Rev. D, 91(9), 094013–6pp.
Abstract: Based on previous studies that support the important role of the f(2)(1270), f'(2)(1525), and (K) over bar (2)*(1430) resonances in the J/psi[psi(2S)] -> phi(omega)VV decays, we make an analysis of the analogous decays of Upsilon(1S) and Upsilon(2S), taking into account recent experimental data. In addition, we study the J/psi and psi(2S) radiative decays and we also made predictions for the radiative decay of Upsilon(1S) and Upsilon(2S) into gamma f(2)(1270), gamma f(2)'(1525), gamma f(0)(1370) and gamma f(0)(1710) comparing with the recent results of a CLEO experiment. We can compare our results for ratios of decay rates with eight experimental ratios and find agreement in all but one case, where experimental problems are discussed.
|
|
|
Lorusso, G. et al, & Montaner-Piza, A. (2015). beta-Decay Half-Lives of 110 Neutron-Rich Nuclei across the N=82 Shell Gap: Implications for the Mechanism and Universality of the Astrophysical r Process. Phys. Rev. Lett., 114(19), 192501–7pp.
Abstract: The beta-decay half-lives of 110 neutron-rich isotopes of the elements from 37 Rb to 50 Sn were measured at the Radioactive Isotope Beam Factory. The 40 new half-lives follow robust systematics and highlight the persistence of shell effects. The new data have direct implications for r-process calculations and reinforce the notion that the second (A approximate to 130) and the rare-earth-element (A approximate to 160) abundance peaks may result from the freeze-out of an (n, gamma) reversible arrow (gamma, n) equilibrium. In such an equilibrium, the new half-lives are important factors determining the abundance of rare-earth elements, and allow for a more reliable discussion of the r process universality. It is anticipated that universality may not extend to the elements Sn, Sb, I, and Cs, making the detection of these elements in metal-poor stars of the utmost importance to determine the exact conditions of individual r-process events.
|
|
|
ATLAS Collaboration(Aad, G. et al), Cabrera Urban, S., Castillo Gimenez, V., Costa, M. J., Fernandez Martinez, P., Ferrer, A., et al. (2015). Search for a CP-odd Higgs boson decaying to Zh in pp collisions at root s=8 TeV with the ATLAS detector. Phys. Lett. B, 744, 163–183.
Abstract: A search for a heavy, CP-odd Higgs boson, A, decaying into a Z boson and a 125 GeV Higgs boson, h, with the ATLAS detector at the LHC is presented. The search uses proton-proton collision data at a centre-of-mass energy of 8 TeV corresponding to an integrated luminosity of 20.3 fb(-1). Decays of CP-even h bosons to tau tau or bb pairs with the Z boson decaying to electron or muon pairs are considered, as well as h -> bb decays with the Z boson decaying to neutrinos. No evidence for the production of an A boson in these channels is found and the 95% confidence level upper limits derived for sigma(gg -> A) x BR(A -> Zh) x BR(h -> f (f) over bar) are 0.098-0.013 pb for f = tau and 0.57-0.014 pb for f = b in a range of m(A) = 220-1000 GeV. The results are combined and interpreted in the context of two-Higgs-doublet models.
|
|
|
Cabello, J., Etxebeste, A., Llosa, G., & Ziegler, S. I. (2015). Simulation study of PET detector limitations using continuous crystals. Phys. Med. Biol., 60(9), 3673–3694.
Abstract: Continuous crystals can potentially obtain better intrinsic detector spatial resolution compared to pixelated crystals, additionally providing depth of interaction (DoI) information from the light distribution. To achieve high performance sophisticated interaction position estimation algorithms are required. There are a number of algorithms in the literature applied to different crystal dimensions and different photodetectors. However, the different crystal properties and photodetector array geometries have an impact on the algorithm performance. In this work we analysed, through Monte Carlo simulations, different combinations of realistic crystals and photodetector parameters to better understand their influence on the interaction position estimation accuracy, with special emphasis on the DoI. We used an interaction position estimation based on an analytical model for the present work. Different photodetector granulation schemes were investigated. The impact of the number of crystal faces readout by photodetectors was studied by simulating scenarios with one and two photodetectors. In addition, crystals with different levels of reflection and aspect ratios (AR) were analysed. Results showed that the impact of photodetector granularity is mainly shown near the edges and specially in the corners of the crystal. The resulting intrinsic spatial resolution near the centre with a 12 x 12 x 10 mm(3) LYSO crystal was 0.7-0.9 mm, while the average spatial resolution calculated on the entire crystal was 0.77 +/- 0.18 mm for all the simulated geometries with one and two photodetectors. Having front and back photodetectors reduced the DoI bias (Euclidean distance between estimated DoI and real DoI) and improved the transversal resolution near the corners. In scenarios with one photodetector, small AR resulted in DoI inaccuracies for absorbed events at the entrance of the crystal. These inaccuracies were slightly reduced either by increasing the AR or reducing the amount of reflected light, and highly mitigated using two photodetectors. Using one photodetector, we obtained a piecewise DoI error model with a DoI resolution of 0.4-0.9 mm for a 1.2 AR crystal, and we observed that including a second photodetector or reducing the amount of reflections reduced the DoI bias but did not significantly improve the DoI resolution. Translating the piecewise DoI error model obtained in this study to image reconstruction we obtained a spatial resolution variability of 0.39 mm using 85% of the FoV, compared to 2.59 mm and 1.87 mm without DoI correction or with a dual layer system, respectively.
|
|