|   | 
Details
   web
Records
Author Orrigo, S.E.A.; Tain, J.L.; Mont-Geli, N.; Tarifeño-Saldivia, A.; Fraile, L.M.; Grieger, M.; Agramunt, J.; Algora, A.; Bemmerer, D.; Calvino, F.; Cortes, G.; De Blas, A.; Dillmann, I.; Dominguez Bugarin, A.; Garcia, R.; Nacher, E.; Tolosa-Delgado, A.
Title Long-term evolution of the neutron rate at the Canfranc Underground Laboratory Type Journal Article
Year 2022 Publication European Physical Journal C Abbreviated Journal Eur. Phys. J. C
Volume 82 Issue 9 Pages 814 - 11pp
Keywords
Abstract We report results on the long-term variation of the neutron counting rate at the Canfranc Underground Laboratory, of importance for several low-background experiments installed there, including rare-event searches. The measurement campaign was performed employing the High Efficiency Neutron Spectrometry Array (HENSA) mounted in Hall A and lasted 412 live days. The present study is the first long-term measurement of the neutron rate with sensitivity over a wide range of neutron energies (from thermal up to 0.1 GeV and beyond) performed in any underground laboratory so far. Data on the environmental variables inside the experimental hall (radon concentration, air temperature, air pressure and humidity) were also acquired during all the measurement campaign. We have investigated for the first time the evolution of the neutron rate for different energies of the neutrons and its correlation with the ambient variables.
Address [Orrigo, S. E. A.; Tain, J. L.; Agramunt, J.; Algora, A.; Nacher, E.; Tolosa-Delgado, A.] Univ Valencia, Inst Fis Corpuscular, CSIC, Valencia 46071, Spain, Email: Sonja.Orrigo@ific.uv.es
Corporate Author Thesis
Publisher (up) Springer Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1434-6044 ISBN Medium
Area Expedition Conference
Notes WOS:000853333800003 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 5358
Permanent link to this record
 

 
Author R3B Collaboration (Heil, M. et al); Nacher, E.
Title A new Time-of-flight detector for the (RB)-B-3 setup Type Journal Article
Year 2022 Publication European Physical Journal A Abbreviated Journal Eur. Phys. J. A
Volume 58 Issue 12 Pages 248 - 19pp
Keywords
Abstract We present the design, prototype developments and test results of the new time-of-flight detector (ToFD) which is part of the R3B experimental setup at GSI and FAIR, Darmstadt, Germany. The ToFD detector is able to detect heavy-ion residues of all charges at relativistic energies with a relative energy precision sigma_Delta E/Delta E of up to 1% and a time precision of up to 14 ps (sigma). Together with an elaborate particle-tracking system, the full identification of relativistic ions from hydrogen up to uranium in mass and nuclear charge is possible.
Address [Heil, M.; Kelic-Heil, A.; Aumann, T.; Boretzky, K.; Caesar, C.; Fruehauf, J.; Glorius, J.; Heggen, H.; Kiselev, O.; Koch, K.; Koerper, D.; Kurz, N.; Loeher, B.; Litvinov, Y.; Rossi, D.; Savran, D.; Simon, H.; Toernqvist, H. T.; Varga, L.; Wamers, F.] GSI Helmholtzzentrum Schwerionenforsch, Planckstr 1, D-64291 Darmstadt, Germany, Email: M.Heil@gsi.de
Corporate Author Thesis
Publisher (up) Springer Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1434-6001 ISBN Medium
Area Expedition Conference
Notes WOS:000901484400002 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 5456
Permanent link to this record
 

 
Author Nacher, E.; Briz, J.A.; Nerio, A.N.; Perea, A.; Tavora, V.G.; Tengblad, O.; Ciemala, M.; Cieplicka-Orynczak, N.; Maj, A.; Mazurek, K.; Olko, P.; Zieblinski, M.; Borge, M.J.G.
Title Characterization of a novel proton-CT scanner based on Silicon and LaBr3(Ce) detectors Type Journal Article
Year 2024 Publication European Physical Journal Plus Abbreviated Journal Eur. Phys. J. Plus
Volume 139 Issue 5 Pages 404 - 9pp
Keywords
Abstract Treatment planning systems at proton-therapy centres entirely use X-ray computed tomography (CT) as primary imaging technique to infer the proton treatment doses to tumour and healthy tissues. However, proton stopping powers in the body, as derived from X-ray images, suffer from important proton-range uncertainties. In order to reduce this uncertainty in range, one could use proton-CT images instead. The main goal of this work is to test the capabilities of a newly-developed proton-CT scanner, based on the use of a set of tracking detectors and a high energy resolution scintillator for the residual energy of the protons. Different custom-made phantoms were positioned at the field of view of the scanner and were irradiated with protons at the CCB proton-therapy center in Krakow. We measured with the phantoms at different angles and produced sinograms that were used to obtain reconstructed images by Filtered Back-Projection. The obtained images were used to determine the capabilities of our scanner in terms of spatial resolution and proton Relative Stopping Power (RSP) mapping and validate its use as proton-CT scanner. The results show that the scanner can produce medium-high quality images, with spatial resolution better than 2 mm in radiography, below 3 mm in tomography and resolving power in the RSP comparable to other state-of-the-art pCT scanners.
Address [Nacher, E.] Univ Valencia, CSIC, Inst Fis Corpuscular, Valencia 46980, Spain, Email: enrique.nacher@csic.es
Corporate Author Thesis
Publisher (up) Springer Heidelberg Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 2190-5444 ISBN Medium
Area Expedition Conference
Notes WOS:001218502700005 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 6123
Permanent link to this record