|
Records |
Links |
|
Author |
Valiente-Dobon, J.J. et al; Egea, J.; Huyuk, T.; Gadea, A.; Aliaga, R.; Jurado-Gomez, M.L.; Perez-Vidal, R.M. |
|
|
Title |
NEDA-NEutron Detector Array |
Type |
Journal Article |
|
Year |
2019 |
Publication |
Nuclear Instruments & Methods in Physics Research A |
Abbreviated Journal |
Nucl. Instrum. Methods Phys. Res. A |
|
|
Volume |
927 |
Issue |
|
Pages |
81-86 |
|
|
Keywords |
NEDA; Nuclear structure; Gamma-ray spectroscopy; Neutron detector; Liquid scintillator; Digital electronics; Neutron-gamma discrimination |
|
|
Abstract |
The NEutron Detector Array, NEDA, will form the next generation neutron detection system that has been designed to be operated in conjunction with gamma-ray arrays, such as the tracking-array AGATA, to aid nuclear spectroscopy studies. NEDA has been designed to be a versatile device, with high-detection efficiency, excellent neutron-gamma discrimination, and high rate capabilities. It will be employed in physics campaigns in order to maximise the scientific output, making use of the different stable and radioactive ion beams available in Europe. The first implementation of the neutron detector array NEDA with AGATA 1 pi was realised at GANIL. This manuscript reviews the various aspects of NEDA. |
|
|
Address |
[Valiente-Dobon, J. J.; Jaworski, G.; Goasduff, A.; Egea, J.; Modamio, V; de Angelis, G.; Bissiato, E.; Carturan, S.; Cocconi, P.; Conventi, D.; Deltoro, J. M.; Hadynska-Klekn, K.; Illan, A.; Raggio, A.; Siciliano, M.; Zanon, I] Ist Nazl Fis Nucl, Lab Nazl Legnaro, Legnaro, Italy, Email: valiente@lnl.infn.it |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Elsevier Science Bv |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0168-9002 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
WOS:000462142700010 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
yes |
|
|
Call Number |
IFIC @ pastor @ |
Serial |
3956 |
|
Permanent link to this record |
|
|
|
|
Author |
Egea Canet, F.J. et al; Gadea, A.; Huyuk, T. |
|
|
Title |
A New Front-End High-Resolution Sampling Board for the New-Generation Electronics of EXOGAM2 and NEDA Detectors |
Type |
Journal Article |
|
Year |
2015 |
Publication |
IEEE Transactions on Nuclear Science |
Abbreviated Journal |
IEEE Trans. Nucl. Sci. |
|
|
Volume |
62 |
Issue |
3 |
Pages |
1056-1062 |
|
|
Keywords |
Acquisition in HP-Ge detectors; high-speed ADCs; low-noise electronics design |
|
|
Abstract |
This paper presents the final design and results of the FADC Mezzanine for the EXOGAM (EXOtic GAMma array spectrometer) and NEDA (Neutron Detector Array) detectors. The measurements performed include those of studying the effective number of bits, the energy resolution using HP-Ge detectors, as well as timing histograms and discrimination performance. Finally, the conclusion shows how a common digitizing device has been integrated in the experimental environment of two very different detectors which combine both low-noise acquisition and fast sampling rates. Not only the integration fulfilled the expected specifications on both systems, but it also showed how a study of synergy between detectors could lead to the reduction of resources and time by applying a common strategy. |
|
|
Address |
[Egea Canet, F. J.; Gonzalez, V.; Sanchis, E.] Univ Valencia, Dept Elect Engn, Escola Tecn Super Engn, Valencia, Spain, Email: jaegea@ific.uv.es |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Ieee-Inst Electrical Electronics Engineers Inc |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0018-9499 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
WOS:000356458000028 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
yes |
|
|
Call Number |
IFIC @ pastor @ |
Serial |
2278 |
|
Permanent link to this record |
|
|
|
|
Author |
Egea Canet, F.J. et al; Gadea, A.; Huyuk, T. |
|
|
Title |
Digital Front-End Electronics for the Neutron Detector NEDA |
Type |
Journal Article |
|
Year |
2015 |
Publication |
IEEE Transactions on Nuclear Science |
Abbreviated Journal |
IEEE Trans. Nucl. Sci. |
|
|
Volume |
62 |
Issue |
3 |
Pages |
1063-1069 |
|
|
Keywords |
Digital systems; front-end electronics; neutron detectors; neutron-gamma discrimination |
|
|
Abstract |
This paper presents the design of the NEDA (Neutron Detector Array) electronics, a first attempt to involve the use of digital electronics in large neutron detector arrays. Starting from the front-end modules attached to the PMTs (PhotoMultiplier Tubes) and ending up with the data processing workstations, a comprehensive electronic system capable of dealing with the acquisition and pre-processing of the neutron array is detailed. Among the electronic modules required, we emphasize the front-end analog processing, the digitalization, digital pre-processing and communications firmware, as well as the integration of the GTS (Global Trigger and Synchronization) system, already used successfully in AGATA (Advanced Gamma Tracking Array). The NEDA array will be available for measurements in 2016. |
|
|
Address |
[Egea Canet, F. J.; Gonzalez, V.; Sanchis, E.] Univ Valencia, Dept Elect Engn, Escola Tecn Super Engn, Valencia, Spain, Email: jaegea@ific.uv.es |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Ieee-Inst Electrical Electronics Engineers Inc |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0018-9499 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
WOS:000356458000029 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
yes |
|
|
Call Number |
IFIC @ pastor @ |
Serial |
2279 |
|
Permanent link to this record |
|
|
|
|
Author |
Krzysiek, M. et al; Gadea, A.; Huyuk, T.; Barrientos, D. |
|
|
Title |
Study of the soft dipole modes in Ce-140 via inelastic scattering of O-17 |
Type |
Journal Article |
|
Year |
2014 |
Publication |
Physica Scripta |
Abbreviated Journal |
Phys. Scr. |
|
|
Volume |
89 |
Issue |
5 |
Pages |
054016 - 6pp |
|
|
Keywords |
pygmy dipole resonances; inelastic scattering; AGATA detector; gamma spectroscopy |
|
|
Abstract |
The main aim of this study was a deeper understanding of the nuclear structure properties of the soft dipole modes in Ce-140, excited via inelastic scattering of weakly bound O-17 projectiles. An important aim was to investigate the 'splitting' of the PDR into two parts: a low-energy isoscalar component dominated by neutron-skin oscillations and a higher-energy component lying on the tail of the giant dipole resonance of a rather isovector character. This was already observed for this nucleus, investigated in (alpha, alpha') and (gamma,gamma') experiments. The experiment was performed at Laboratori Nazionali di Legnaro, Italy. Inelastic scattering of O-17 ion beam at 20 MeV A(-1) was used to excite the resonance modes in the Ce-140 target. Gamma-rays were registered by five triple clusters of AGATA-Demonstrator and nine large volume scintillators (LaBr3). The scattered O-17 ions were identified by two Delta E – E Si telescopes of the TRACE array mounted inside the scattering chamber. The telescopes consisted of two segmented Si-pad detectors, each of 60 pixels. Very preliminary data have shown a strong domination of the E1 transitions in the 'pygmy' region with a character more similar to the one obtained in alpha scattering experiment. |
|
|
Address |
[Krzysiek, M.; Kmiecik, M.; Maj, A.; Bednarczyk, P.; Ciemala, M.; Fornal, B.; Grebosz, J.; Mazurek, K.; Meczynski, W.; Zieblinski, M.] Polish Acad Sci, H Niewodniczanski Inst Nucl Phys, Krakow, Poland, Email: mateusz.krzysiek@ifj.edu.pl |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Iop Publishing Ltd |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
0031-8949 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
WOS:000335785300016 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
yes |
|
|
Call Number |
IFIC @ pastor @ |
Serial |
1790 |
|
Permanent link to this record |
|
|
|
|
Author |
Huyuk, T. et al; Gadea, A.; Aliaga-Varea, R.J.; Domingo-Pardo, C. |
|
|
Title |
Conceptual design of the early implementation of the NEutron Detector Array (NEDA) with AGATA |
Type |
Journal Article |
|
Year |
2016 |
Publication |
European Physical Journal A |
Abbreviated Journal |
Eur. Phys. J. A |
|
|
Volume |
52 |
Issue |
3 |
Pages |
55 - 8pp |
|
|
Keywords |
|
|
|
Abstract |
The NEutron Detector Array (NEDA) project aims at the construction of a new high-efficiency compact neutron detector array to be coupled with large gamma-ray arrays such as AGATA. The application of NEDA ranges from its use as selective neutron multiplicity filter for fusion-evaporation reaction to a large solid angle neutron tagging device. In the present work, possible configurations for the NEDA coupled with the Neutron Wall for the early implementation with AGATA has been simulated, using Monte Carlo techniques, in order to evaluate their performance figures. The goal of this early NEDA implementation is to improve, with respect to previous instruments, efficiency and capability to select multiplicity for fusion-evaporation reaction channels in which 1, 2 or 3 neutrons are emitted. Each NEDA detector unit has the shape of a regular hexagonal prism with a volume of about 3.23 l and it is filled with the EJ301 liquid scintillator, that presents good neutron-gamma discrimination properties. The simulations have been performed using a fusion-evaporation event generator that has been validated with a set of experimental data obtained in the Ni-58 + Fe-56 reaction measured with the Neutron Wall detector array. |
|
|
Address |
[Hueyuek, Tayfun; Gadea, Andres; Jose Aliaga-Varea, Ramon; Domingo-Pardo, Cesar] Univ Valencia, CSIC, Inst Fis Corpuscular, E-46980 Paterna, Valencia, Spain, Email: huyuk@ific.uv.es |
|
|
Corporate Author |
|
Thesis |
|
|
|
Publisher |
Springer |
Place of Publication |
|
Editor |
|
|
|
Language |
English |
Summary Language |
|
Original Title |
|
|
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
|
|
Series Volume |
|
Series Issue |
|
Edition |
|
|
|
ISSN |
1434-6001 |
ISBN |
|
Medium |
|
|
|
Area |
|
Expedition |
|
Conference |
|
|
|
Notes |
WOS:000372866900001 |
Approved |
no |
|
|
Is ISI |
yes |
International Collaboration |
yes |
|
|
Call Number |
IFIC @ pastor @ |
Serial |
2607 |
|
Permanent link to this record |