|   | 
Details
   web
Records
Author Candela-Juan, C.; Ballester, F.; Perez-Calatayud, J.; Vijande, J.
Title Assaying multiple I-125 seeds with the well-ionization chamber SourceCheck(4 Pi) 33005 and a new insert Type Journal Article
Year 2015 Publication Journal of Contemporary Brachytherapy Abbreviated Journal J. Contemp. Brachytherapy
Volume 7 Issue 6 Pages 492-496
Keywords brachytherapy; insert; quality assurance; prostate; seeds; well chamber
Abstract Purpose: To provide a practical solution that can be adopted in clinical routine to fulfill the AAPM-ESTRO recommendations regarding quality assurance of seeds used in prostate permanent brachytherapy. The aim is to design a new insert for the well-ionization chamber SourceCheck(4 Pi) 33005 (PTW, Germany) that allows evaluating the mean air-kerma strength of up to ten I-125 seeds with one single measurement instead of measuring each seed individually. Material and methods: The material required is: a) the SourceCheck(4 Pi) 33005 well-ionization chamber provided with a PTW insert to measure the air-kerma strength S-K of one single seed at a time; b) a newly designed insert that accommodates ten seeds in one column, which allows measuring the mean S-K of the ten seeds in one single measurement; and c) a container with ten seeds from the same batch and class of the seeds used for the patient implant, and a set of nine non-radioactive seeds.The new insert is characterized by determining its calibration coefficient, used to convert the reading of the well-chamber when ten seeds are measured to their mean S-K. The proposed method is validated by comparing the mean S-K of the ten seeds obtained from the new insert with the individual measurement of S-K of each seed, evaluated with the PTW insert. Results: The ratio between the calibration coefficient of the new insert and the calibration coefficient of the PTW insert for the SourceCheck(4 Pi) 33005 is 1.135 +/- 0.007 (k = 1). The mean S-K of a set of ten seeds evaluated with this new system is in agreement with the mean value obtained from measuring independently the S-K of each seed. Conclusions: The new insert and procedure allow evaluating the mean S-K of ten seeds prior to the implant in a single measurement. The method is faster and more efficient from radiation protection point of view than measuring the individual S-K of each seed.
Address [Candela-Juan, Cristian; Perez-Calatayud, Jose] La Fe Univ, Dept Radiat Oncol, Phys Sect, E-46026 Valencia, Spain, Email: ccanjuan@gmail.com
Corporate Author Thesis
Publisher (down) Termedia Publishing House Ltd Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1689-832x ISBN Medium
Area Expedition Conference
Notes WOS:000368381300010 Approved no
Is ISI yes International Collaboration no
Call Number IFIC @ pastor @ Serial 2533
Permanent link to this record
 

 
Author Vijande, J.; Valcarce, A.; Carames, T.F.; Richard, J.M.
Title Multiquark Systems Type Journal Article
Year 2014 Publication Few-Body Systems Abbreviated Journal Few-Body Syst.
Volume 55 Issue 8-10 Pages 675-681
Keywords
Abstract In this talk we tackle the description of hadron spectroscopy in terms of the constituent quark model. We focus on the mesonic charm sector, where several of the new reported resonances seem to defy their classification as simple quark-antiquark states. We pay special attention to higher order Fock space components in describing excited states of the meson spectra in close connection with the hadron-hadron interaction. The main goal of the present study is a coherent understanding of the low-energy hadron phenomenology without enforcing any particular model, to constrain its characteristics and learn about low-energy realization of the theory.
Address [Vijande, J.] Univ Valencia, Dept Fis Atom Mol & Nucl, Valencia, Spain, Email: javier.vijande@uv.es
Corporate Author Thesis
Publisher (down) Springer Wien Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0177-7963 ISBN Medium
Area Expedition Conference
Notes WOS:000339828900015 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 1864
Permanent link to this record
 

 
Author Valcarce, A.; Vijande, J.; Richard, J.M.; Garcilazo, H.
Title Stability of Heavy Tetraquarks Type Journal Article
Year 2018 Publication Few-Body Systems Abbreviated Journal Few-Body Syst.
Volume 59 Issue 2 Pages 9 - 7pp
Keywords
Abstract We discuss the stability of tetraquark systems with two different masses. After some reminders about the stability of very asymmetric QQ (q) over bar(q) over bar tetraquarks, we demonstrate that in the all-heavy limit q -> Q, the system becomes unstable for standard color-additive models. We also analyze the consequences of symmetry breaking for Qq (Q) over bar(q) over bar configurations: we find a kind of metastability between the lowest threshold Q (Q) over bar + q (q) over bar and the highest one, Q (q) over bar + (Q) over barq, and we calculate the width of the resonance. Our results are consistent with the experimental observation of narrow hadrons lying well above their lowest decay threshold.
Address [Valcarce, A.] Univ Salamanca, Dept Fis Fundamental, E-37008 Salamanca, Spain, Email: valcarce@usal.es;
Corporate Author Thesis
Publisher (down) Springer Wien Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0177-7963 ISBN Medium
Area Expedition Conference
Notes WOS:000427011200005 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 3574
Permanent link to this record
 

 
Author Garcilazo, H.; Valcarce, A.; Vijande, J.
Title Stable bound states of N's, Lambda's and Xi's Type Journal Article
Year 2017 Publication Revista Mexicana de Fisica Abbreviated Journal Rev. Mex. Fis.
Volume 63 Issue 5 Pages 411-422
Keywords Baryon-Baryon interactions; Faddeev equations; variational approaches
Abstract We review our recent work about the stability of strange few-body systems containing N's, Lambda's, and Xi's. We make use of local central Yukawa-type Malfliet-Tjon interactions reproducing the low-energy parameters and phase shifts of the nucleon-nucleon system and the latest updates of the hyperon-nucleon and hyperon-hyperon ESCO8c Nijmegen potentials. We solve the three-and four-body bound-state problems by means of Faddeev equations and a generalized Gaussian variational method, respectively. The hypertriton, Lambda np(I)J(P) = (1/2)1/2(+), is bound by 144 keV; the recently discussed Lambda nn (I)J(P) = (1/2)1/2(+) system is unbound, as well as the Lambda Lambda nn (I)J(P) = (1)0(+) system, being just above threshold. Our results indicate that the Xi NN, Xi Xi N and Xi Xi NN systems with maximal isospin might be bound.
Address [Garcilazo, H.] Inst Politecn Nacl, Escuela Super Fis & Matemat, Edificio 9, Mexico City 07738, DF, Mexico, Email: humberto@esfm.ipn.mx;
Corporate Author Thesis
Publisher (down) Soc Mexicana Fisica Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0035-001x ISBN Medium
Area Expedition Conference
Notes WOS:000410015700003 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 3291
Permanent link to this record
 

 
Author Vijande, J.; Granero, D.; Perez-Calatayud, J.; Ballester, F.
Title Monte Carlo dosimetric study of the medium dose rate CSM40 source Type Journal Article
Year 2013 Publication Applied Radiation and Isotopes Abbreviated Journal Appl. Radiat. Isot.
Volume 82 Issue Pages 283-288
Keywords Brachytherapy; Cs-137 seed; TG-43 based dosimetry; Monte Carlo
Abstract The Cs-137 medium dose rate (MDR) CSM40 source model (Eckert & Ziegler BEBIG, Germany) is in clinical use but no dosimetric dataset has been published. This study aims to obtain dosimetric data for the CSM40 source for its use in clinical practice as required by the American Association of Physicists in Medicine (AAPM) and the European Society for Radiotherapy and Oncology (ESTRO). Penelope2008 and Geant4 Monte Carlo codes were used to characterize this source dosimetrically. It was located in an unbounded water phantom with composition and mass density as recommended by AAPM and ESTRO. Due to the low photon energies of Cs-137, absorbed dose was approximated by collisional kerma. Additional simulations were performed to obtain the air-kerma strength, sic. Mass-energy absorption coefficients in water and air were consistently derived and used to calculate collisional kerma. Results performed with both radiation transport codes showed agreement typically within 0.05%. Dose rate constant, radial dose function and anisotropy function are provided for the CSM40 and compared with published data for other commercially available Cs-137 sources. An uncertainty analysis has been performed. The data provided by this study can be used as input data and verification in the treatment planning systems. (C) 2013 Elsevier Ltd. All rights reserved.
Address [Vijande, J.; Ballester, F.] Univ Valencia, Dept Atom Mol & Nucl Phys, E-46100 Burjassot, Spain, Email: Javier.vijande@uv.es
Corporate Author Thesis
Publisher (down) Pergamon-Elsevier Science Ltd Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0969-8043 ISBN Medium
Area Expedition Conference
Notes WOS:000328804000043 Approved no
Is ISI yes International Collaboration no
Call Number IFIC @ pastor @ Serial 1678
Permanent link to this record