Borja-Lloret, M., Barrientos, L., Bernabeu, J., Lacasta, C., Muñoz, E., Ros, A., et al. (2023). Influence of the background in Compton camera images for proton therapy treatment monitoring. Phys. Med. Biol., 68(14), 144001–16pp.
Abstract: Objective. Background events are one of the most relevant contributions to image degradation in Compton camera imaging for hadron therapy treatment monitoring. A study of the background and its contribution to image degradation is important to define future strategies to reduce the background in the system. Approach. In this simulation study, the percentage of different kinds of events and their contribution to the reconstructed image in a two-layer Compton camera have been evaluated. To this end, GATE v8.2 simulations of a proton beam impinging on a PMMA phantom have been carried out, for different proton beam energies and at different beam intensities. Main results. For a simulated Compton camera made of Lanthanum (III) Bromide monolithic crystals, coincidences caused by neutrons arriving from the phantom are the most common type of background produced by secondary radiations in the Compton camera, causing between 13% and 33% of the detected coincidences, depending on the beam energy. Results also show that random coincidences are a significant cause of image degradation at high beam intensities, and their influence in the reconstructed images is studied for values of the time coincidence windows from 500 ps to 100 ns. Significance. Results indicate the timing capabilities required to retrieve the fall-off position with good precision. Still, the noise observed in the image when no randoms are considered make us consider further background rejection methods.
|
Brzezinski, K. et al. (2023). Detection of range shifts in proton beam therapy using the J-PET scanner: a patient simulation study. Phys. Med. Biol., 68(14), 145016–17pp.
Abstract: Objective. The Jagiellonian positron emission tomography (J-PET) technology, based on plastic scintillators, has been proposed as a cost effective tool for detecting range deviations during proton therapy. This study investigates the feasibility of using J-PET for range monitoring by means of a detailed Monte Carlo simulation study of 95 patients who underwent proton therapy at the Cyclotron Centre Bronowice (CCB) in Krakow, Poland. Approach. Discrepancies between prescribed and delivered treatments were artificially introduced in the simulations by means of shifts in patient positioning and in the Hounsfield unit to the relative proton stopping power calibration curve. A dual-layer, cylindrical J-PET geometry was simulated in an in-room monitoring scenario and a triple-layer, dual-head geometry in an in-beam protocol. The distribution of range shifts in reconstructed PET activity was visualized in the beam's eye view. Linear prediction models were constructed from all patients in the cohort, using the mean shift in reconstructed PET activity as a predictor of the mean proton range deviation. Main results. Maps of deviations in the range of reconstructed PET distributions showed agreement with those of deviations in dose range in most patients. The linear prediction model showed a good fit, with coefficient of determination r (2) = 0.84 (in-room) and 0.75 (in-beam). Residual standard error was below 1 mm: 0.33 mm (in-room) and 0.23 mm (in-beam). Significance. The precision of the proposed prediction models shows the sensitivity of the proposed J-PET scanners to shifts in proton range for a wide range of clinical treatment plans. Furthermore, it motivates the use of such models as a tool for predicting proton range deviations and opens up new prospects for investigations into the use of intra-treatment PET images for predicting clinical metrics that aid in the assessment of the quality of delivered treatment.
|
Balbinot, R., & Fabbri, A. (2023). The Hawking Effect in the Particles-Partners Correlations. Physics, 5(4), 968–982.
Abstract: We analyze the correlations functions across the horizon in Hawking black hole radiation to reveal the correlations between Hawking particles and their partners. The effects of the underlying space-time on this are shown in various examples ranging from acoustic black holes to regular black holes.
|
Lasa-Alonso, J., Olmos-Trigo, J., Devescovi, C., Hernandez, P., Garcia-Etxarri, A., & Molina-Terriza, G. (2023). Resonant helicity mixing of electromagnetic waves propagating through matter. Phys. Rev. Res., 5(2), 023116–8pp.
Abstract: Dual scatterers preserve the helicity of an incident field, whereas antidual scatterers flip it completely. In this setting of linear electromagnetic scattering theory, we provide a completely general proof on the nonexistence of passive antidual scatterers. However, we show that scatterers fulfilling the refractive index matching condition flip the helicity of the fields very efficiently without being in contradiction with the law of energy conservation. Moreover, we find that this condition is paired with the impedance matching condition in several contexts of electromagnetism and, in particular, within Fresnel's and Mie's scattering problems. Finally, we show that indexmatched media induce a resonant helicity mixing on the propagating electromagnetic waves. We reach this conclusion by identifying that the refractive index matching condition leads to the phenomenon of avoided crossing.
|
LHCb Collaboration(Aaij, R. et al), Jaimes Elles, S. J., Jashal, B. K., Martinez-Vidal, F., Oyanguren, A., Rebollo De Miguel, M., et al. (2023). First Observation of a Doubly Charged Tetraquark and Its Neutral Partner. Phys. Rev. Lett., 131(4), 041902–12pp.
Abstract: A combined amplitude analysis is performed for the decays B0-+ D0D thorn s & pi;- and B thorn -+ D-D thorn s & pi; thorn , which are related by isospin symmetry. The analysis is based on data collected by the LHCb detector in proton -proton collisions at center-of-mass energies of 7, 8, and 13 TeV. The full data sample corresponds to an integrated luminosity of 9 fb-1. Two new resonant states with masses of 2.908 ⠂ 0.011 ⠂ 0.020 GeV and widths of 0.136 ⠂ 0.023 ⠂ 0.013 GeV are observed, which decay to D thorn s & pi; thorn and D thorn s & pi;- respectively. The former state indicates the first observation of a doubly charged open-charm tetraquark state with minimal quark content 1/2cs over bar ud over bar ⠃, and the latter state is a neutral tetraquark composed of 1/2cs over bar u over bar d ⠃ quarks. Both states are found to have spin-parity of 0 thorn , and their resonant parameters are consistent with each other, which suggests that they belong to an isospin triplet.
|