Balibrea-Correa, J., Lerendegui-Marco, J., Calvo, D., Caballero, L., Babiano, V., Ladarescu, I., et al. (2021). A first prototype of C6D6 total-energy detector with SiPM readout for neutron capture time-of-flight experiments. Nucl. Instrum. Methods Phys. Res. A, 985, 164709–8pp.
Abstract: Low efficiency total-energy detectors (TEDs) are one of the main tools for neutron capture cross section measurements utilizing the time-of-flight (TOF) technique. State-of-the-art TEDs are based on a C6D6 liquid-scintillation cell optically coupled to a fast photomultiplier tube. The large photomultiplier tube represents yet a significant contribution to the so-called neutron sensitivity background, which is one of the most conspicuous sources of uncertainty in this type of experiments. Here we report on the development of a first prototype of a TED based on a silicon-photomultiplier (SiPM) readout, thus resulting in a lightweight and much more compact detector. Apart from the envisaged improvement in neutron sensitivity, the new system uses low voltage (+28 V) and low current supply (-50 mA), which is more practical than the-kV supply required by conventional photomultipliers. One important difficulty hindering the earlier implementation of SiPM readout for this type of detector was the large capacitance for the output signal when all pixels of a SiPM array are summed together. The latter leads to long pulse rise and decay times, which are not suitable for time-of-flight experiments. In this work we demonstrate the feasibility of a Schottky-diode multiplexing readout approach, that allows one to preserve the excellent timing properties of SiPMs, hereby paving the way for their implementation in future neutron TOF experiments.
|
|
|
Mistry, A. K. et al, Tain, J. L., Agramunt, J., Algora, A., Guadilla, V., Morales, A. I., et al. (2022). The DESPEC setup for GSI and FAIR. Nucl. Instrum. Methods Phys. Res. A, 1033, 166662–18pp.
Abstract: The DEcay SPECtroscopy (DESPEC) setup for nuclear structure investigations was developed and commissioned at GSI, Germany in preparation for a full campaign of experiments at the FRS and Super-FRS. In this paper, we report on the first employment of the setup in the hybrid configuration with the AIDA implanter coupled to the FATIMA LaBr3(Ce) fast-timing array, and high-purity germanium detectors. Initial results are shown from the first experiments carried out with the setup. An overview of the setup and function is discussed, including technical advancements along the path.
|
|
|
n_TOF Collaboration(Belloni, F. et al), Domingo-Pardo, C., & Tain, J. L. (2012). Neutron-induced fission cross section measurement of U-233, Am-241 and Am-243 in the energy range 0.5 MeV <= E-n <= 20 MeV at n_TOF at CERN. Phys. Scr., T150, 014005–4pp.
Abstract: Neutron-induced fission cross section measurements of U-233, Am-243 and Am-241 relative to U-235 have been carried out at the neutron time-of-flight facility n_TOF at CERN. A fast ionization chamber has been employed. All samples were located in the same detector; therefore the studied elements and the reference U-235 target are subject to the same neutron beam.
|
|
|
n_TOF Collaboration(Lederer, C. et al), Domingo-Pardo, C., & Tain, J. L. (2011). Au-197(n,gamma) cross section in the unresolved resonance region. Phys. Rev. C, 83(3), 034608–11pp.
Abstract: The cross section of the reaction Au-197(n,gamma) was measured with the time-of-flight technique at the n_TOF (neutron time-of-flight) facility in the unresolved resonance region between 5 and 400 keV using a pair of C6D6 (where D denotes H-2) liquid scintillators for the detection of prompt capture gamma rays. The results with a total uncertainty of 3.9%-6.7% for a resolution of 20 bins per energy decade show fair agreement with the Evaluated Nuclear Data File Version B-VII.0 (ENDF/B-VII.0), which contains the standard evaluation. The Maxwellian-averaged cross section (MACS) at 30 keV is in excellent agreement with the one according to the ENDF/B-VII.0 evaluation and 4.7% higher than the MACS measured independently by activation technique. Structures in the cross section, which had also been reported earlier, have been interpreted as being due to clusters of resonances.
|
|
|
n_TOF Collaboration(Paradela, C. et al), Domingo-Pardo, C., & Tain, J. L. (2010). Neutron-induced fission cross section of U-234 and Np-237 measured at the CERN Neutron Time-of-Flight (n_TOF) facility. Phys. Rev. C, 82(3), 034601–11pp.
Abstract: A high-resolution measurement of the neutron-induced fission cross section of U-234 and Np-237 has been performed at the CERN Neutron Time-of-Flight facility. The cross sections have been determined in a wide energy range from 1 eV to 1 GeV using the evaluated U-235 cross section as reference. In these measurements the energy determination for the U-234 resonances could be improved, whereas previous discrepancies for the Np-237 resonances were confirmed. New cross-section data are provided for high neutron energies that go beyond the limits of prior evaluations, obtaining important differences in the case of Np-237.
|
|