toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author n_TOF Collaboration (Sabate-Gilarte et al.); Domingo-Pardo, C.; Tain, J.L.; Tarifeño-Saldivia, A. doi  openurl
  Title High-accuracy determination of the neutron flux in the new experimental area n_TOF-EAR2 at CERNx Type Journal Article
  Year 2017 Publication (up) European Physical Journal A Abbreviated Journal Eur. Phys. J. A  
  Volume 53 Issue 10 Pages 210 - 13pp  
  Keywords  
  Abstract A new high flux experimental area has recently become operational at the nTOF facility at CERN. This new measuring station, nTOF-EAR2, is placed at the end of a vertical beam line at a distance of approximately 20m from the spallation target. The characterization of the neutron beam, in terms of flux, spatial profile and resolution function, is of crucial importance for the feasibility study and data analysis of all measurements to be performed in the new area. In this paper, the measurement of the neutron flux, performed with different solid-state and gaseous detection systems, and using three neutronconverting reactions considered standard in different energy regions is reported. The results of the various measurements have been combined, yielding an evaluated neutron energy distribution in a wide energy range, from 2meV to 100MeV, with an accuracy ranging from 2%, at low energy, to 6% in the high-energy region. In addition, an absolute normalization of the n_TOF-EAR2 neutron flux has been obtained by means of an activation measurement performed with 197 Au foils in the beam.  
  Address [Sabate-Gilarte, M.; Vlachoudis, V.; Aberle, O.; Bacak, M.; Brugger, M.; Calviani, M.; Cardella, R.; Cerutti, F.; Chiaveri, E.; Ferrari, A.; Hernandez-Prieto, A.; Kadi, Y.; Losito, R.; Macina, D.; Mingrone, F.; Montesano, S.; Rubbia, C.; Weiss, C.] CERN, European Org Nucl Res, Geneva, Switzerland, Email: massimo.barbagallo@ba.infn.it  
  Corporate Author Thesis  
  Publisher Springer Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1434-6001 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000413766400002 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 3350  
Permanent link to this record
 

 
Author n_TOF Collaboration (Mastromarco, M. et al); Domingo-Pardo, C.; Tain, J.L. url  doi
openurl 
  Title Cross section measurements of Gd-155,Gd-157(n,) induced by thermal and epithermal neutrons Type Journal Article
  Year 2019 Publication (up) European Physical Journal A Abbreviated Journal Eur. Phys. J. A  
  Volume 55 Issue 1 Pages 9 - 20pp  
  Keywords  
  Abstract Neutron capture cross section measurements on Gd-155 and Gd-157 were performed using the time-of-flight technique at the nTOF facility at CERN on isotopically enriched samples. The measurements were carried out in the nTOF experimental area EAR1, at 185 m from the neutron source, with an array of 4 C6D6 liquid scintillation detectors. At a neutron kinetic energy of 0.0253 eV, capture cross sections of 62.2(2.2) and 239.8(8.4) kilobarn have been derived for Gd-155 and Gd-157, respectively, with up to 6% deviation relative to values presently reported in nuclear data libraries, but consistent with those values within 1.6 standard deviations. A resonance shape analysis has been performed in the resolved resonance region up to 181 eV and 307 eV, respectively for Gd-155 and Gd-157, where on average, resonance parameters have been found in good agreement with evaluations. Above these energies and up to 1 keV, the observed resonance-like structure of the cross section has been analysed and characterised. From a statistical analysis of the observed neutron resonances we deduced: neutron strength function of 2.01(28)x10-4 and 2.17(41)x10-4; average total radiative width of 106.8(14) meV and 101.1(20) meV and s-wave resonance spacing 1.6(2) eV and 4.8(5) eV for n + Gd-155 and n + Gd-157 systems, respectively.  
  Address [Mastromarco, M.; Barbagallo, M.; Colonna, N.; Damone, L. A.; Mazzone, A.; Tagliente, G.; Variale, V.] Ist Nazl Fis Nucl, Sez Bari, Bari, Italy, Email: massimi@bo.infn.it  
  Corporate Author Thesis  
  Publisher Springer Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1434-6001 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000456675600003 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 3892  
Permanent link to this record
 

 
Author n_TOF Collaboration (Amaducci, S. et al); Domingo-Pardo, C.; Tain, J.L. url  doi
openurl 
  Title Measurement of the U-235(n, f) cross section relative to the Li-6(n, t) and B-10(n,alpha) standards from thermal to 170 keV neutron energy range at n_TOF Type Journal Article
  Year 2019 Publication (up) European Physical Journal A Abbreviated Journal Eur. Phys. J. A  
  Volume 55 Issue 7 Pages 120 - 19pp  
  Keywords  
  Abstract .The U-235(n, f ) cross section was measured at n_TOF relative to Li-6(n, t) and B-10(n,alpha) , with high resolution ( L=183.49(2) m) and in a wide energy range (25meV-170keV) with 1.5% systematic uncertainty, making use of a stack of six samples and six silicon detectors placed in the neutron beam. This allowed us to make a direct comparison of the yields of the U-235(n, f ) and of the two reference reactions under the same experimental conditions, and taking into account the forward/backward emission asymmetry. A hint of an anomaly in the 10-30keV neutron energy range had been previously observed in other experiments, indicating a cross section systematically lower by several percent relative to major evaluations. The present results indicate that the cross section in the 9-18keV neutron energy range is indeed overestimated by almost 5% in the recently released evaluated data files ENDF/B-VIII.0 and JEFF3.3, as a consequence of a 7% overestimate in a single GMA node in the IAEA reference file. Furthermore, these new high-resolution data confirm the existence of resonance-like structures in the keV neutron energy region. The results here reported may lead to a reduction of the uncertainty in the 1-100keV neutron energy region. Finally, from the present data, a value of 249.7 +/- 1.4( stat )+/- 0.94( syst ) b<bold>eV has been extracted for the cross section integral between </bold>7.8 and 11eV, confirming the value of 247.5 +/- 3 b<bold>eV recently established as a standard</bold>.  
  Address [Amaducci, S.; Cosentino, L.; Finocchiaro, P.; Musumarra, A.] INFN, Lab Nazl Sud, Catania, Italy, Email: finocchiaro@lns.infn.it  
  Corporate Author Thesis  
  Publisher Springer Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1434-6001 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000477050900001 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 4083  
Permanent link to this record
 

 
Author Napiralla, P. et al; Domingo-Pardo, C. doi  openurl
  Title Benchmarking the PreSPEC@GSI experiment for Coulex-multipolarimetry on the pi(p3/2) -> pi(p1/2) spin-flip transition in 85Br Type Journal Article
  Year 2020 Publication (up) European Physical Journal A Abbreviated Journal Eur. Phys. J. A  
  Volume 56 Issue 5 Pages 147 - 10pp  
  Keywords  
  Abstract A first performance test of the Coulomb excitation multipolarimetry (Coulex-multipolarimetry) method is presented. It is based on a 85Br pp3/ 2. pp1/ 2 spinflip experiment performed as part of the PreSPEC-AGATA campaign at the GSI Helmholtzzentrum fur Schwerionen-forschung (GSI). Via determination of background levels around the expected 85Br excitations as well as measured 197Au excitations, an upper limit for the M1 transition strength of the 1/2- 1. 3/2- g.s. transition in 85Br and a lower beam time limit for upcoming experimental campaigns utilizing Coulex-multipolarimetry have been inferred. The impact of the use of AGATA in its anticipated 1p configuration on these estimates is deduced via Geant4 simulations.  
  Address [Napiralla, P.; Lettmann, M.; Stahl, C.; Pietralla, N.; Boutachkov, P.; Cortes, M. L.; John, P. R.; Lizarazo, C.; Louchart-Henning, C.; Merchan, E.; Moeller, O.; Moeller, T.; Ralet, D.; Werner, V] Tech Univ Darmstadt, Inst Kernphys, Schlossgartenstr 9, D-64289 Darmstadt, Germany, Email: pnapiralla@ikp.tu-darmstadt.de  
  Corporate Author Thesis  
  Publisher Springer Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1434-6001 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000541855500002 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 4441  
Permanent link to this record
 

 
Author Babiano-Suarez, V. et al; Lerendegui-Marco, J.; Balibrea-Correa, J.; Caballero, L.; Calvo, D.; Ladarescu, I.; Real, D.; Domingo-Pardo, C. url  doi
openurl 
  Title Imaging neutron capture cross sections: i-TED proof-of-concept and future prospects based on Machine-Learning techniques Type Journal Article
  Year 2021 Publication (up) European Physical Journal A Abbreviated Journal Eur. Phys. J. A  
  Volume 57 Issue 6 Pages 197 - 17pp  
  Keywords  
  Abstract i-TED is an innovative detection system which exploits Compton imaging techniques to achieve a superior signal-to-background ratio in (n, gamma) cross-section measurements using time-of-flight technique. This work presents the first experimental validation of the i-TED apparatus for high-resolution time-of-flight experiments and demonstrates for the first time the concept proposed for background rejection. To this aim, the Au-197(n, gamma) and Fe-56(n, gamma) reactions were studied at CERN n_TOF using an i-TED demonstrator based on three position-sensitive detectors. Two C6D6 detectors were also used to benchmark the performance of i-TED. The i-TED prototype built for this study shows a factor of similar to 3 higher detection sensitivity than state-of-the-art C6D6 detectors in the 10 keV neutron-energy region of astrophysical interest. This paper explores also the perspectives of further enhancement in performance attainable with the final i-TED array consisting of twenty position-sensitive detectors and newanalysis methodologies based on Machine-Learning techniques.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 1434-6001 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000662881100001 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 4875  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records:
ific federMinisterio de Ciencia e InnovaciĆ³nAgencia Estatal de Investigaciongva