|
LHCb Collaboration(Aaij, R. et al), Jaimes Elles, S. J., Jashal, B. K., Martinez-Vidal, F., Oyanguren, A., Rebollo De Miguel, M., et al. (2023). Measurement of the CKM angle γ with B± → D[K∓π±π±π∓] h± decays using a binned phase-space approach. J. High Energy Phys., 07(7), 138–31pp.
Abstract: The CKM angle gamma is determined from CP-violating observables measured in B-+/- -> D[K--/+pi(+/-)pi(+/-)pi(-/+)]h(+/-), (h = K, pi) decays, where the measurements are performed in bins of the decay phase-space of the D meson. Using proton-proton collision data collected by the LHCb experiment at centre-of-mass energies of 7, 8 and 13TeV, corresponding to a total integrated luminosity of 9 fb(-1), gamma is determined to be gamma = (54.8 (+6.0)(-5.8) (+0.6)(-0.6) (+6.7)(-4.3))degrees, where the first uncertainty is statistical, the second systematic and the third from the external inputs on the coherence factors and strong phases of the D-meson decays.
|
|
|
LHCb Collaboration(Aaij, R. et al), Jaimes Elles, S. J., Jashal, B. K., Martinez-Vidal, F., Oyanguren, A., Rebollo De Miguel, M., et al. (2023). Evidence for the decays B0 → (D)over-bar(*)0 φ and updated measurements of the branching fractions of the Bs0 → (D)over-bar(*)0 φ decays. J. High Energy Phys., 10(10), 123–26pp.
Abstract: Evidence for the decays B-0 -> (D) over bar (0)phi and B-0 -> (D) over bar (*0) phi is reported with a significance of 3.6 sigma and 4.3 sigma, respectively. The analysis employs pp collision data at centre-of-mass energies root s = 7, 8 and 13TeV collected by the LHCb detector and corresponding to an integrated luminosity of 9 fb(-1). The branching fractions are measured to be B(B-0 -> (D) over bar (0)phi) = (7.7 +/- 2.1 +/- 0.7 +/- 0.7) x 10(-7), B(B-0 -> (D) over bar (*0)phi) = (2.2 +/- 05 +/- 0.2 +/- 0.2) x 10(-6). In these results, the first uncertainty is statistical, the second systematic, and the third is related to the branching fraction of the B-0 -> (D) over bar K-0(+) K- decay, used for normalisation. By combining the branching fractions of the decays B-0 -> (D) over bar ((*)0)phi and B-0 -> (D) over bar ((*)0)omega, the omega-phi mixing angle delta is constrained to be tan(2)delta = (3.6 +/- 0.7 +/- 0.4) x 10(-3), where the first uncertainty is statistical and the second systematic. An updated measurement of the branching fractions of the B-s(0) -> (D) over bar ((*)0).phi decays, which can be used to determine the CKM angle gamma, leads to B(B-s(0) -> (D) over bar (0)phi) = (2.30 +/- 0.10 +/- 0.11 +/- 0.20) x 10(-5), B(B-s(0) -> (D) over bar (*0)phi) = (3.17 +/- 0.16 +/- 0.17 +/- 0.27) x 10(-5).
|
|
|
LHCb Collaboration(Aaij, R. et al), Jaimes Elles, S. J., Jashal, B. K., Martinez-Vidal, F., Oyanguren, A., Rebollo De Miguel, M., et al. (2023). Measurement of the CKM angle γ using the B± → D*h± channels. J. High Energy Phys., 12(12), 013–32pp.
Abstract: A measurement of the CP-violating observables from B -> (DK +/-)-K-* and B-+/- -> D-*pi(+/-) decays is presented, where D-*(D) is an admixture of D-*0 and D-0 (D-0 and (0)) states and is reconstructed through the decay chains D-*-> D pi(0)/gamma and D -> KS0 pi+pi-/KS0K+K-. The measurement is performed by analysing the signal yield variation across the D decay phase space and is independent of any amplitude model. The data sample used was collected by the LHCb experiment in proton-proton collisions and corresponds to a total integrated luminosity of 9 fb(-1) at centre-of-mass energies of 7, 8 and 13 TeV. The CKM angle gamma is determined to be (69(-14)(+13))degrees using the measured CP-violating observables. The hadronic parameters r(B)(D)*(K +/-),r(B)(D)*(pi +/-),delta(D)(B)*(K +/-),delta(D)(B)*(pi +/-), which are the ratios and strong phase differences between favoured and suppressed B-+/- decays, are also reported.
|
|
|
LHCb Collaboration(Aaij, R. et al), Jaimes Elles, S. J., Jashal, B. K., Martinez-Vidal, F., Oyanguren, A., Rebollo De Miguel, M., et al. (2024). A model-independent measurement of the CKM angle γ in partially reconstructed B±→D∗h± decays with D→K0Sh+h-(h=π,K). J. High Energy Phys., 02(2), 118–30pp.
Abstract: A measurement of CP-violating observables in B-+/-->(DK +/-)-K-& lowast; and B-+/--> D-& lowast;pi(+/-) decays is made where the photon or neutral pion from the D-& lowast;-> D gamma or D-& lowast;-> D pi(0) decay is not reconstructed. The D meson is reconstructed in the self-conjugate decay modes, D -> K-S(0)pi(+)pi(-) or D ->(KSK+K-)-K-0. The distribution of signal yields in the D decay phase space is analysed in a model-independent way. The measurement uses a data sample collected in proton-proton collisions at centre-of-mass energies of 7, 8, and 13 TeV, corresponding to a total integrated luminosity of approximately 9 fb(-1). The B-+/-->(DK +/-)-K-& lowast; and B-+/--> D-& lowast;pi(+/-) CP-violating observables are interpreted in terms of hadronic parameters and the CKM angle gamma, resulting in a measurement of gamma=(92(-17)(+21))degrees. The total uncertainty includes the statistical and systematic uncertainties, and the uncertainty due to external strong-phase inputs.
|
|
|
Linhart, V., Burdette, D., Chessi, E., Cindro, V., Clinthorne, N. H., Cochran, E., et al. (2011). Spectroscopy study of imaging devices based on silicon Pixel Array Detector coupled to VATAGP7 read-out chips. J. Instrum., 6, C01092–8pp.
Abstract: Spectroscopic and timing response studies have been conducted on a detector module consisting of a silicon Pixel Array Detector bonded on two VATAGP7 read-out chips manufactured by Gamma-Medica Ideas using laboratory gamma sources and the internal calibration facilities (the calibration system of the read-out chips). The performed tests have proven that the chips have (i) non-linear calibration curves which can be approximated by power functions, (ii) capability to measure the energy of photons with energy resolution better than 2 keV (exact range and resolution depend on experimental setup), (iii) the internal calibration facility which provides 6 out of 16 available internal calibration charges within our region of interest (spanning the Compton edge of 511 keV photons). The peaks induced by the internal calibration facility are suitable for a fit of the calibration curves. However, they are not suitable for measurements of equivalent noise charge because their full width at half maximum varies with their amplitude. These facts indicate that the VATAGP7 chips are useful and precise tools for a wide variety of spectroscopic devices. We have also explored time walk of the module and peaking time of the spectroscopy signals provided by the chips. We have observed that (iv) the time walk is caused partly by the peaking time of the signals provided by the fast shaper of the chips and partly by the timing uncertainty related to the varying position of the photon interaction, (v) the peaking time of the spectroscopy signals provided by the chips increases with increasing pulse height.
|
|