toggle visibility Search & Display Options

Select All    Deselect All
 |   | 
Details
   print
  Records Links
Author n_TOF Collaboration (Amaducci, S. et al); Babiano-Suarez, V.; Caballero-Ontanaya, L.; Domingo-Pardo, C.; Ladarescu, I.; Tain, J.L. doi  openurl
  Title First Results of the Ce-140(n,gamma)Ce-141 Cross-Section Measurement at n_TOF Type Journal Article
  Year 2021 Publication (down) Universe Abbreviated Journal Universe  
  Volume 7 Issue 6 Pages 200 - 11pp  
  Keywords  
  Abstract An accurate measurement of the Ce-140(n,gamma) energy-dependent cross-section was performed at the n_TOF facility at CERN. This cross-section is of great importance because it represents a bottleneck for the s-process nucleosynthesis and determines to a large extent the cerium abundance in stars. The measurement was motivated by the significant difference between the cerium abundance measured in globular clusters and the value predicted by theoretical stellar models. This discrepancy can be ascribed to an overestimation of the Ce-140 capture cross-section due to a lack of accurate nuclear data. For this measurement, we used a sample of cerium oxide enriched in Ce-140 to 99.4%. The experimental apparatus consisted of four deuterated benzene liquid scintillator detectors, which allowed us to overcome the difficulties present in the previous measurements, thanks to their very low neutron sensitivity. The accurate analysis of the p-wave resonances and the calculation of their average parameters are fundamental to improve the evaluation of the Ce-140 Maxwellian-averaged cross-section.  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000665969800001 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 4877  
Permanent link to this record
 

 
Author Massimi, C.; Cristallo, S.; Domingo-Pardo, C.; Lederer-Woods, C. doi  openurl
  Title n_TOF: Measurements of Key Reactions of Interest to AGB Stars Type Journal Article
  Year 2022 Publication (down) Universe Abbreviated Journal Universe  
  Volume 8 Issue 2 Pages 100 - 19pp  
  Keywords s process; MACS; time of flight  
  Abstract In the last 20 years, the neutron time-of-flight facility nTOF at CERN has been providing relevant data for the astrophysical slow neutron capture process (s process). At nTOF, neutron-induced radiative capture (n,gamma) as well as (n,p) and (n,alpha) reaction cross sections are measured as a function of energy, using the time-of-flight method. Improved detection systems, innovative ideas and collaborations with other neutron facilities have lead to a considerable contribution of the n_TOF collaboration to studying the s process in asymptotic giant branch stars. Results have been reported for stable and radioactive samples, i.e.,Mg- 24,Mg-25,Mg-26, Al-26, S-33,Fe- 54,Fe-57, Ni-58,Ni-59,Ni-62,Ni-63, Ge-70,Ge-72,Ge-73, Zr-90,Zr-91,Zr-92,Zr-93,Zr-94,Zr-96, La-139, Ce-140, Pm-147, Sm-151,Gd- 154,Gd-155,Gd-157, Tm-171, Os-186,Os-187,Os-188, Au-197, Tl-203,Tl-204,Pb- 204,Pb-206,Pb-207 and Bi-209 isotopes, while others are being studied or planned to be studied in the near future. In this contribution, we present an overview of the most successful achievements, and an outlook of future challenging measurements, including ongoing detection system developments.  
  Address [Massimi, Cristian] Univ Bologna, Dept Phys & Astron, I-40127 Bologna, Italy, Email: cristian.massimi@unibo.it;  
  Corporate Author Thesis  
  Publisher Mdpi Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000762514400001 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 5144  
Permanent link to this record
 

 
Author Lerendegui-Marco, J.; Balibrea-Correa, J.; Babiano-Suarez, V.; Ladarescu, I.; Domingo-Pardo, C. url  doi
openurl 
  Title Towards machine learning aided real-time range imaging in proton therapy Type Journal Article
  Year 2022 Publication (down) Scientific Reports Abbreviated Journal Sci Rep  
  Volume 12 Issue 1 Pages 2735 - 17pp  
  Keywords  
  Abstract Compton imaging represents a promising technique for range verification in proton therapy treatments. In this work, we report on the advantageous aspects of the i-TED detector for proton-range monitoring, based on the results of the first Monte Carlo study of its applicability to this field. i-TED is an array of Compton cameras, that have been specifically designed for neutron-capture nuclear physics experiments, which are characterized by gamma-ray energies spanning up to 5-6 MeV, rather low gamma-ray emission yields and very intense neutron induced gamma-ray backgrounds. Our developments to cope with these three aspects are concomitant with those required in the field of hadron therapy, especially in terms of high efficiency for real-time monitoring, low sensitivity to neutron backgrounds and reliable performance at the high gamma-ray energies. We find that signal-to-background ratios can be appreciably improved with i-TED thanks to its light-weight design and the low neutron-capture cross sections of its LaCl3 crystals, when compared to other similar systems based on LYSO, CdZnTe or LaBr3. Its high time-resolution (CRT similar to 500 ps) represents an additional advantage for background suppression when operated in pulsed HT mode. Each i-TED Compton module features two detection planes of very large LaCl3 monolithic crystals, thereby achieving a high efficiency in coincidence of 0.2% for a point-like 1 MeV gamma-ray source at 5 cm distance. This leads to sufficient statistics for reliable image reconstruction with an array of four i-TED detectors assuming clinical intensities of 10(8) protons per treatment point. The use of a two-plane design instead of three-planes has been preferred owing to the higher attainable efficiency for double time-coincidences than for threefold events. The loss of full-energy events for high energy gamma-rays is compensated by means of machine-learning based algorithms, which allow one to enhance the signal-to-total ratio up to a factor of 2.  
  Address [Lerendegui-Marco, Jorge; Balibrea-Correa, Javier; Babiano-Suarez, Victor; Ladarescu, Ion; Domingo-Pardo, Cesar] Univ Valencia, CSIC, Inst Fis Corpuscular, Valencia, Spain, Email: jorge.lerendegui@ific.uv.es  
  Corporate Author Thesis  
  Publisher Nature Portfolio Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 2045-2322 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000757537100018 Approved no  
  Is ISI yes International Collaboration no  
  Call Number IFIC @ pastor @ Serial 5136  
Permanent link to this record
 

 
Author n_TOF Collaboration (Alcayne, V. et al); Balibrea-Correa, J.; Domingo-Pardo, C.; Lerendegui-Marco, J.; Babiano-Suarez, V.; Ladarescu, I. url  doi
openurl 
  Title A Segmented Total Energy Detector (sTED) optimized for (n,γ) cross-section measurements at n_TOF EAR2 Type Journal Article
  Year 2024 Publication (down) Radiation Physics and Chemistry Abbreviated Journal Radiat. Phys. Chem.  
  Volume 217 Issue Pages 11pp  
  Keywords Neutron capture; PHWT; Scintillation detectors; Monte Carlo simulation  
  Abstract The neutron time-of-flight facility nTOF at CERN is a spallation source dedicated to measurements of neutroninduced reaction cross-sections of interest in nuclear technologies, astrophysics, and other applications. Since 2014, Experimental ARea 2 (EAR2) is operational and delivers a neutron fluence of similar to 4 center dot 10(7) neutrons per nominal proton pulse, which is similar to 50 times higher than the one of Experimental ARea 1 (EAR1) of similar to 8 center dot 10(5) neutrons per pulse. The high neutron flux at EAR2 results in high counting rates in the detectors that challenged the previously existing capture detection systems. For this reason, a Segmented Total Energy Detector (sTED) has been developed to overcome the limitations in the detector's response, by reducing the active volume per module and by using a photo-multiplier (PMT) optimized for high counting rates. This paper presents the main characteristics of the sTED, including energy and time resolution, response to gamma-rays, and provides as well details of the use of the Pulse Height Weighting Technique (PHWT) with this detector. The sTED has been validated to perform neutron-capture cross-section measurements in EAR2 in the neutron energy range from thermal up to at least 400 keV. The detector has already been successfully used in several measurements at nTOF EAR2.  
  Address [Alcayne, V.; Cano-Ott, D.; Garcia, J.; Gonzalez-Romero, E.; Martinez, T.; de Rada, A. Perez; Plaza, J.; Sanchez-Caballero, A.; Mendoza, E.] Ctr Invest Energet Medioambient & Tecnol CIEMAT, Madrid, Spain, Email: victor.alcayne@ciemat.es  
  Corporate Author Thesis  
  Publisher Pergamon-Elsevier Science Ltd Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0969-806x ISBN Medium  
  Area Expedition Conference  
  Notes WOS:001185584800001 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 5999  
Permanent link to this record
 

 
Author n_TOF Collaboration (Massimi, C. et al.); Domingo-Pardo, C.; Giubrone, G.; Tain, J.L. url  doi
openurl 
  Title Neutron spectroscopy of Mg-26 states: Constraining the stellar neutron source Ne-22(alpha, n)Mg-25 Type Journal Article
  Year 2017 Publication (down) Physics Letters B Abbreviated Journal Phys. Lett. B  
  Volume 768 Issue Pages 1-6  
  Keywords s Process; alpha+Ne-22; Neutron spectroscopy  
  Abstract This work reports on accurate, high-resolution measurements of the Mg-25(n, gamma)Mg-26 and Mg-25(n, tot) cross sections in the neutron energy range from thermal to about 300 keV, leading to a significantly improved Mg-25(n, gamma)Mg-26 parametrization. The relevant resonances for n+Mg-25 were characterized from a combined R-matrix analysis of the experimental data. This resulted in an unambiguous spin/parity assignment of the corresponding excited states in Mg-26. With this information experimental upper limits of the reaction rates for Ne-22(alpha, n)Mg-25 and Ne-22(alpha, gamma)Mg-26 were established, potentially leading to a significantly higher (alpha, n)/(alpha, gamma) ratio than previously evaluated. The impact of these results has been studied for stellar models in the mass range 2 to 25 M-circle dot. (C) 2017 The Author(s). Published by Elsevier B.V.  
  Address [Massimi, C.; Barbagallo, M.; Becvar, F.; Bisterzok, S.; Castelluccio, D. M.; Eleftheriadis, C.; Finocchiaro, P.; Kokkoris, M.; Marganiec, J.; Plompen, A.; Praena, J.; Rubbia, C.; Weiss, C.] Ist Nazl Fis Nucl, Bologna, Italy, Email: cristian.massimi@bo.infn.it  
  Corporate Author Thesis  
  Publisher Elsevier Science Bv Place of Publication Editor  
  Language English Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0370-2693 ISBN Medium  
  Area Expedition Conference  
  Notes WOS:000400677700001 Approved no  
  Is ISI yes International Collaboration yes  
  Call Number IFIC @ pastor @ Serial 3112  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print

Save Citations:
Export Records:
ific federMinisterio de Ciencia e InnovaciĆ³nAgencia Estatal de Investigaciongva