|
T2K Collaboration(Abe, K. et al), Cervera-Villanueva, A., Escudero, L., Gomez-Cadenas, J. J., Hansen, C., Monfregola, L., et al. (2011). Indication of Electron Neutrino Appearance from an Accelerator-Produced Off-Axis Muon Neutrino Beam. Phys. Rev. Lett., 107(4), 041801–8pp.
Abstract: The T2K experiment observes indications of nu(mu) -> nu(mu) e appearance in data accumulated with 1.43 x 10(20) protons on target. Six events pass all selection criteria at the far detector. In a three-flavor neutrino oscillation scenario with |Delta m(23)(2)| = 2.4 x 10(-3) eV(2), sin(2)2 theta(23) = 1 and sin(2)2 theta(13) = 0, the expected number of such events is 1.5 +/- 0.3(syst). Under this hypothesis, the probability to observe six or more candidate events is 7 x 10(-3), equivalent to 2.5 sigma significance. At 90% C.L., the data are consistent with 0.03(0.04) < sin(2)2 theta(13) < 0.28(0.34) for delta(CP) = 0 and a normal (inverted) hierarchy.
|
|
|
T2K Collaboration(Abe, K. et al), Cervera-Villanueva, A., Escudero, L., Gomez-Cadenas, J. J., Hansen, C., Monfregola, L., et al. (2011). The T2K experiment. Nucl. Instrum. Methods Phys. Res. A, 659(1), 106–135.
Abstract: The T2K experiment is a long baseline neutrino oscillation experiment. Its main goal is to measure the last unknown lepton sector mixing angle theta(13) by observing nu(e) appearance in a nu(mu) beam. It also aims to make a precision measurement of the known oscillation parameters, Delta m(23)(2) and sin(2)2 theta(23), via nu(mu) disappearance studies. Other goals of the experiment include various neutrino cross-section measurements and sterile neutrino searches. The experiment uses an intense proton beam generated by the J-PARC accelerator in Tokai, Japan, and is composed of a neutrino beamline, a near detector complex (ND280), and a far detector (Super-Kamiokande) located 295 km away from J-PARC. This paper provides a comprehensive review of the instrumentation aspect of the T2K experiment and a summary of the vital information for each subsystem.
|
|
|
T2K Collaboration(Abe, K. et al), Cervera-Villanueva, A., Escudero, L., Gomez-Cadenas, J. J., Hansen, C., Monfregola, L., et al. (2012). First muon-neutrino disappearance study with an off-axis beam. Phys. Rev. D, 85(3), 031103–8pp.
Abstract: We report a measurement of muon-neutrino disappearance in the T2K experiment. The 295-km muon-neutrino beam from Tokai to Kamioka is the first implementation of the off-axis technique in a long-baseline neutrino oscillation experiment. With data corresponding to 1.43 x 10(20) protons on target, we observe 31 fully-contained single mu-like ring events in Super-Kamiokande, compared with an expectation of 104 +/- 14 (syst) events without neutrino oscillations. The best-fit point for two-flavor nu(mu) -> nu(tau) oscillations is sin(2)(2 theta(23)) = 0.98 and vertical bar Delta m(32)(2)vertical bar = 2.65 x 10(-3) eV(2). The boundary of the 90% confidence region includes the points sin(2)(2 theta(23)), vertical bar Delta m(32)(2)vertical bar = (1.0, 3.1 x 10(-3) eV(2)), (0.84, 2.65 x 10(-3) eV(2)) and (1.0, 2.2 x 10(-3) eV(2)).
|
|
|
T2K Collaboration(Abe, K. et al), Cervera-Villanueva, A., Escudero, L., Gomez-Cadenas, J. J., Hansen, C., Monfregola, L., et al. (2012). Measurements of the T2K neutrino beam properties using the INGRID on-axis near detector. Nucl. Instrum. Methods Phys. Res. A, 694, 211–223.
Abstract: Precise measurement of neutrino beam direction and intensity was achieved based on a new concept with modularized neutrino detectors. INGRID (Interactive Neutrino GRID) is an on-axis near detector for the T2K long baseline neutrino oscillation experiment. INGRID consists of 16 identical modules arranged in horizontal and vertical arrays around the beam center. The module has a sandwich structure of iron target plates and scintillator trackers. INGRID directly monitors the muon neutrino beam profile center and intensity using the number of observed neutrino events in each module. The neutrino beam direction is measured with accuracy better than 0.4 mrad from the measured profile center. The normalized event rate is measured with 4% precision. (C) 2012 Elsevier B.V. All rights reserved.
|
|