LHCb Collaboration(Aaij, R. et al), Garcia Martin, L. M., Henry, L., Martinez-Vidal, F., Oyanguren, A., Remon Alepuz, C., et al. (2017). Observation of D-0 meson decays to pi(+) pi(-) mu(+) mu(-) and K+ K- mu(+) mu(-) final states. Phys. Rev. Lett., 119(18), 181805–10pp.
Abstract: The first observation of the D-0 -> pi(+) pi(-) mu(+) mu(-) and D-0 -> K+ K- mu(+) mu(-) decays is reported using a sample of proton-proton collisions collected by LHCb at a center-of-mass energy of 8 TeV, and corresponding to 2 fb(-1) of integrated luminosity. The corresponding branching fractions are measured using as normalization the decay D-0 -> K- pi(+) [mu(+) mu(-)](rho 0/omega), where the two muons are consistent with coming from the decay of a rho(0) or omega meson. The results are B(D-0 -> pi(+) pi(-) mu(+) mu(-)) = (9.64 +/- 0.48 +/- 0.51 +/- 0.97) x 10(-7) and B(D-0 -> K+ K- mu(+) mu(-)) = (1.54 +/- 0.27 +/- 0.09 +/- 0.16) x 10(-7), where the uncertainties are statistical, systematic, and due to the limited knowledge of the normalization branching fraction. The dependence of the branching fraction on the dimuon mass is also investigated.
|
|
|
Doncel, M., Cederwall, B., Gadea, A., Gerl, J., Kojouharov, I., Martin, S., et al. (2017). Performance and imaging capabilities of the DEGAS high-resolution gamma-ray detector array for the DESPEC experiment at FAIR. Nucl. Instrum. Methods Phys. Res. A, 873, 36–38.
Abstract: Monte Carlo simulations of one of the possible configurations of the imaging phase for the DEGAS spectrometer situated at the DESPEC/NUSTAR experiment have been performed. The geometry consists of the coupling of the high-resolution gamma spectroscopy array, AGATA, with a high-resolution segmented planar detector utilized as an implantation detector in a compact configuration. The sensitivity and performance of the array in terms of efficiency and imaging capability is deduced.
|
|
|
Ibanez-Rosello, B., Bautista-Ballesteros, J. A., Candela-Juan, C., Villaescusa, J. I., Ballester, F., Vijande, J., et al. (2017). Evaluation of the shielding in a treatment room with an electronic brachytherapy unit. J. Radiol. Prot., 37(2), N5–N12.
Abstract: Esteya (R) (Elekta Brachytherapy, Veenendaal, The Netherlands) is an electronic brachytherapy (eBT) system based on a 69.5 kVp x-ray source and a set of collimators of 1 to 3 cm in diameter, used for treating non-melanoma skin cancer lesions. This study aims to estimate room shielding requirements for this unit. The non-primary (scattered and leakage) ambient dose equivalent rates were measured with a Berthold LB-133 monitor (Berthold Technologies, Bad Wildbad, Germany). The latter ranges from 17 mSv h(-1) at 0.25 m distance from the x-ray source to 0.1 mSv h(-1) at 2.5 m. The necessary room shielding was then estimated following US and some European guidelines. The room shielding for all barriers considered was below 2 mmPb. The dose to a companion who, exceptionally, would stay with the patient during all treatment was estimated to be below 1 mSv if a leaded apron is used. In conclusion, Esteya shielding requirements are minimal.
|
|
|
Becker, P., Davesne, D., Meyer, J., Navarro, J., & Pastore, A. (2017). Solution of Hartree-Fock-Bogoliubov equations and fitting procedure using the N2LO Skyrme pseudopotential in spherical symmetry. Phys. Rev. C, 96(4), 044330–17pp.
Abstract: We present the development of the extended Skyrme N2LO pseudopotential in the case of spherical even-even nuclei calculations. The energy density functional is first presented. Then we derive the mean-field equations and discuss the numerical method used to solve the resulting fourth-order differential equation together with the behavior of the solutions at the origin. Finally, a fitting procedure for such an N2LO interaction is discussed and we provide a first parametrization. Typical ground-state observables are calculated and compared against experimental data.
|
|
|
n_TOF Collaboration(Sabate-Gilarte et al.), Domingo-Pardo, C., Tain, J. L., & Tarifeño-Saldivia, A. (2017). High-accuracy determination of the neutron flux in the new experimental area n_TOF-EAR2 at CERNx. Eur. Phys. J. A, 53(10), 210–13pp.
Abstract: A new high flux experimental area has recently become operational at the nTOF facility at CERN. This new measuring station, nTOF-EAR2, is placed at the end of a vertical beam line at a distance of approximately 20m from the spallation target. The characterization of the neutron beam, in terms of flux, spatial profile and resolution function, is of crucial importance for the feasibility study and data analysis of all measurements to be performed in the new area. In this paper, the measurement of the neutron flux, performed with different solid-state and gaseous detection systems, and using three neutronconverting reactions considered standard in different energy regions is reported. The results of the various measurements have been combined, yielding an evaluated neutron energy distribution in a wide energy range, from 2meV to 100MeV, with an accuracy ranging from 2%, at low energy, to 6% in the high-energy region. In addition, an absolute normalization of the n_TOF-EAR2 neutron flux has been obtained by means of an activation measurement performed with 197 Au foils in the beam.
|
|