|
Pich, A., & Rodriguez-Sanchez, A. (2016). Determination of the QCD coupling from ALEPH tau decay data. Phys. Rev. D, 94(3), 034027–26pp.
Abstract: We present a comprehensive study of the determination of the strong coupling from tau decay, using the most recent release of the experimental ALEPH data. We critically review all theoretical strategies used in previous works and put forward various novel approaches which allow one to study complementary aspects of the problem. We investigate the advantages and disadvantages of the different methods, trying to uncover their potential hidden weaknesses and test the stability of the obtained results under slight variations of the assumed inputs. We perform several determinations, using different methodologies, and find a very consistent set of results. All determinations are in excellent agreement, and allow us to extract a very reliable value for alpha(s)(m(tau)(2)). The main uncertainty originates in the pure perturbative error from unknown higher orders. Taking into account the systematic differences between the results obtained with the contour-improved perturbation theory and fixed-order perturbation theory prescriptions, we find alpha((nf=3))(s) (m(tau)(2)) = 0.328 +/- 0.013 which implies alpha((nf=5))(s) (M-Z(2)) = 0.1197 +/- 0.0015.
|
|
|
Albiol, F., Corbi, A., & Albiol, A. (2016). Geometrical Calibration of X-Ray Imaging With RGB Cameras for 3D Reconstruction. IEEE Trans. Med. Imaging, 35(8), 1952–1961.
Abstract: We present a methodology to recover the geometrical calibration of conventional X-ray settings with the help of an ordinary video camera and visible fiducials that are present in the scene. After calibration, equivalent points of interest can be easily identifiable with the help of the epipolar geometry. The same procedure also allows the measurement of real anatomic lengths and angles and obtains accurate 3D locations from image points. Our approach completely eliminates the need for X-ray-opaque reference marks (and necessary supporting frames) which can sometimes be invasive for the patient, occlude the radiographic picture, and end up projected outside the imaging sensor area in oblique protocols. Two possible frameworks are envisioned: a spatially shifting X-ray anode around the patient/object and a moving patient that moves/rotates while the imaging system remains fixed. As a proof of concept, experiences with a device under test (DUT), an anthropomorphic phantom and a real brachytherapy session have been carried out. The results show that it is possible to identify common points with a proper level of accuracy and retrieve three-dimensional locations, lengths and shapes with a millimetric level of precision. The presented approach is simple and compatible with both current and legacy widespread diagnostic X-ray imaging deployments and it can represent a good and inexpensive alternative to other radiological modalities like CT.
|
|
|
LHCb Collaboration(Aaij, R. et al), Martinez-Vidal, F., Oyanguren, A., Remon Alepuz, C., Ruiz Valls, P., & Sanchez Mayordomo, C. (2016). Measurement of the CP Asymmetry in B-s(0) – (B)over-bar(s)(0) Mixing. Phys. Rev. Lett., 117(6), 061803–9pp.
Abstract: The CP asymmetry in the mixing of B-s(0) and (B) over bar (0)(s) mesons is measured in proton-proton collision data corresponding to an integrated luminosity of 3.0 fb(-1), recorded by the LHCb experiment at center-of-mass energies of 7 and 8 TeV. Semileptonic B-s(0) and (B) over bar (s) (0) decays are studied in the inclusive mode D-s(-/+)mu(+/-)nu((-)) X-mu with the D-s(-/+) mesons reconstructed in the K+K-pi(-/+) final state. Correcting the observed charge asymmetry for detection and background effects, the CP asymmetry is found to be a(sl)(s) = (0.39 +/- 0.26 +/- 0.20)%, where the first uncertainty is statistical and the second systematic. This is the most precise measurement of a(sl)(s) to date. It is consistent with the prediction from the standard model and will constrain new models of particle physics.
|
|
|
Miranda, O. G., Tortola, M., & Valle, J. W. F. (2016). New Ambiguity in Probing CP Violation in Neutrino Oscillations. Phys. Rev. Lett., 117(6), 061804–5pp.
Abstract: If neutrinos get mass via the seesaw mechanism the mixing matrix describing neutrino oscillations can be effectively nonunitary. We show that in this case the neutrino appearance probabilities involve a new CP phase phi associated with nonunitarity. This leads to an ambiguity in extracting the “standard” three-neutrino phase delta(CP), which can survive even after neutrino and antineutrino channels are combined. Its existence should be taken into account in the planning of any oscillation experiment aiming at a robust measurement of delta(CP).
|
|
|
IceCube Collaboration(Aartsen, M. G. et al), & Salvado, J. (2016). Searches for Sterile Neutrinos with the IceCube Detector. Phys. Rev. Lett., 117(7), 071801–9pp.
Abstract: The IceCube neutrino telescope at the South Pole has measured the atmospheric muon neutrino spectrum as a function of zenith angle and energy in the approximate 320 GeV to 20 TeV range, to search for the oscillation signatures of light sterile neutrinos. No evidence for anomalous nu(mu) or (nu) over bar (mu) disappearance is observed in either of two independently developed analyses, each using one year of atmospheric neutrino data. New exclusion limits are placed on the parameter space of the 3 + 1 model, in which muon antineutrinos experience a strong Mikheyev-Smirnov-Wolfenstein-resonant oscillation. The exclusion limits extend to sin(2)2 theta(24) <= 0.02 at Delta m(2) similar to 0.3 eV(2) at the 90% confidence level. The allowed region from global analysis of appearance experiments, including LSND and MiniBooNE, is excluded at approximately the 99% confidence level for the global best-fit value of vertical bar U-e4 vertical bar(2).
|
|