|
NEXT Collaboration(Haefner, J. et al), Carcel, S., Carrion, J. V., Lopez-March, N., Martin-Albo, J., Muñoz Vidal, J., et al. (2024). Demonstration of event position reconstruction based on diffusion in the NEXT-white detector. Eur. Phys. J. C, 84(5), 518–13pp.
Abstract: Noble element time projection chambers are a leading technology for rare event detection in physics, such as for dark matter and neutrinoless double beta decay searches. Time projection chambers typically assign event position in the drift direction using the relative timing of prompt scintillation and delayed charge collection signals, allowing for reconstruction of an absolute position in the drift direction. In this paper, alternate methods for assigning event drift distance via quantification of electron diffusion in a pure high pressure xenon gas time projection chamber are explored. Data from the NEXT-White detector demonstrate the ability to achieve good position assignment accuracy for both high- and low-energy events. Using point-like energy deposits from Kr-83m calibration electron captures (E similar to 45 keV), the position of origin of low-energy events is determined to 2 cm precision with bias <1 mm. A convolutional neural network approach is then used to quantify diffusion for longer tracks (E >= 1.5 MeV), from radiogenic electrons, yielding a precision of 3 cm on the event barycenter. The precision achieved with these methods indicates the feasibility energy calibrations of better than 1% FWHM at Q(beta beta) in pure xenon, as well as the potential for event fiducialization in large future detectors using an alternate method that does not rely on primary scintillation.
|
|
|
NEXT Collaboration(Mistry, K. et al), Carcel, S., Lopez-March, N., Martin-Albo, J., Novella, P., Querol, M., et al. (2024). Design, characterization and installation of the NEXT-100 cathode and electroluminescence regions. J. Instrum., 19(2), P02007–36pp.
Abstract: NEXT -100 is currently being constructed at the Laboratorio Subterraneo de Canfranc in the Spanish Pyrenees and will search for neutrinoless double beta decay using a high-pressure gaseous time projection chamber (TPC) with 100 kg of xenon. Charge amplification is carried out via electroluminescence (EL) which is the process of accelerating electrons in a high electric field region causing secondary scintillation of the medium proportional to the initial charge. The NEXT -100 EL and cathode regions are made from tensioned hexagonal meshes of 1 m diameter. This paper describes the design, characterization, and installation of these parts for NEXT -100. Simulations of the electric field are performed to model the drift and amplification of ionization electrons produced in the detector under various EL region alignments and rotations. Measurements of the electrostatic breakdown voltage in air characterize performance under high voltage conditions and identify breakdown points. The electrostatic deflection of the mesh is quantified and fit to a first -pr inciples mechanical model. Measurements were performed with both a standalone test EL region and with the NEXT-100 EL region before its installation in the detector. Finally, we describe the parts as installed in NEXT-100, following their deployment in Summer 2023.
|
|
|
T2K Collaboration(Abe, K. et al), Antonova, M., Cervera-Villanueva, A., Molina Bueno, L., & Novella, P. (2023). First measurement of muon neutrino charged-current interactions on hydrocarbon without pions in the final state using multiple detectors with correlated energy spectra at T2K. Phys. Rev. D, 108(11), 112009–32pp.
Abstract: This paper reports the first measurement of muon neutrino charged-current interactions without pions in the final state using multiple detectors with correlated energy spectra at T2K. The data was collected on hydrocarbon targets using the off-axis T2K near detector (ND280) and the on-axis T2K near detector (INGRID) with neutrino energy spectra peaked at 0.6 GeV and 1.1 GeV, respectively. The correlated neutrino flux presents an opportunity to reduce the impact of the flux uncertainty and to study the energy dependence of neutrino interactions. The extracted double-differential cross sections are compared to several Monte Carlo neutrino-nucleus interaction event generators showing the agreement between both detectors individually and with the correlated result.
|
|
|
T2K Collaboration(Abe, K. et al), Antonova, M., Cervera-Villanueva, A., Molina Bueno, L., & Novella, P. (2023). Measurements of the νμ and bar(ν)μ-induced coherent charged pion production cross sections on 12C by the T2K experiment. Phys. Rev. D, 108(9), 092009–15pp.
Abstract: We report an updated measurement of the nu(mu)-induced, and the first measurement of the (nu) over bar (mu)- induced coherent charged pion production cross section on C-12 nuclei in the Tokai-to-Kamioka experiment. This is measured in a restricted region of the final- state phase space for which p(mu,pi) > 0.2 GeV, cos(theta(mu)) > 0.8 and cos(theta(pi)) > 0.6, and at a mean ( anti)neutrino energy of 0.85 GeVusing the T2K near detector. The measured nu(mu) charged current coherent pion production flux-averaged cross section on C-12 is (2.98 +/- 0.37(stat) +/- 0.31(syst)(-0.00)(+0.49)(Q(2) model)) x 10(-40) cm(2). The new measurement of the (nu) over bar (mu)-induced cross section on C-12 is (3.05 +/- 0.71(stat) +/- 0.39(syst)(-0.00)(+-0.74) (Q(2) model)) x 10(-40) cm(2). The results are compatible with both the NEUT 5.4.0 Berger-Sehgal (2009) and GENIE 2.8.0 Rein-Sehgal (2007) model predictions.
|
|
|
NEXT Collaboration(Navarro, K. E. et al), Carcel, S., Carrion, J. V., Lopez, F., Lopez-March, N., Martin-Albo, J., et al. (2023). A compact dication source for Ba2+ tagging and heavy metal ion sensor development. J. Instrum., 18(7), P07044–19pp.
Abstract: We present a tunable metal ion beam that delivers controllable ion currents in the picoamp range for testing of dry-phase ion sensors. Ion beams are formed by sequential atomic evaporation and single or multiple electron impact ionization, followed by acceleration into a sensing region. Controllability of the ionic charge state is achieved through tuning of electrode potentials that influence the retention time in the ionization region. Barium, lead, and cadmium samples have been used to test the system, with ion currents identified and quantified using a quadrupole mass analyzer. Realization of a clean Ba2+ ion beam within a bench-top system represents an important technical advance toward the development and characterization of barium tagging systems for neutrinoless double beta decay searches in xenon gas. This system also provides a testbed for investigation of novel ion sensing methodologies for environmental assay applications, with dication beams of Pb2+ and Cd2+ also demonstrated for this purpose.
|
|