Barenboim, G., & Rasero, J. (2011). Baryogenesis from a right-handed neutrino condensate. J. High Energy Phys., 03(3), 097–15pp.
Abstract: We show that the baryon asymmetry of the Universe can be generated by a strongly coupled right handed neutrino condensate which also drives inflation. The resulting model has only a small number of parameters, which completely determine not only the baryon asymmetry of the Universe and the mass of the right handed neutrino but also the inflationary phase. This feature allows us to make predictions that will be tested by current and planned experiments. As compared to the usual approach our dynamical framework is both economical and predictive.
|
ANTARES Collaboration(Aguilar, J. A. et al), Bigongiari, C., Dornic, D., Emanuele, U., Gomez-Gonzalez, J. P., Hernandez-Rey, J. J., et al. (2011). AMADEUS-The acoustic neutrino detection test system of the ANTARES deep-sea neutrino telescope. Nucl. Instrum. Methods Phys. Res. A, 626, 128–143.
Abstract: The AMADEUS (ANTARES Modules for the Acoustic Detection Under the Sea) system which is described in this article aims at the investigation of techniques for acoustic detection of neutrinos in the deep sea. It is integrated into the ANTARES neutrino telescope in the Mediterranean Sea. Its acoustic sensors, installed at water depths between 2050 and 2300 m, employ piezo-electric elements for the broad-band recording of signals with frequencies ranging up to 125 kHz. The typical sensitivity of the sensors is around – 145 dB re 1 V/mu Pa (including preamplifier). Completed in May 2008, AMADEUS consists of six “acoustic clusters”, each comprising six acoustic sensors that are arranged at distances of roughly 1 m from each other. Two vertical mechanical structures (so-called lines) of the ANTARES detector host three acoustic clusters each. Spacings between the clusters range from 14.5 to 340 m. Each cluster contains custom-designed electronics boards to amplify and digitise the acoustic signals from the sensors. An on-shore computer cluster is used to process and filter the data stream and store the selected events. The daily volume of recorded data is about 10 GB. The system is operating continuously and automatically, requiring only little human intervention. AMADEUS allows for extensive studies of both transient signals and ambient noise in the deep sea, as well as signal correlations on several length scales and localisation of acoustic point sources. Thus the system is excellently suited to assess the background conditions for the measurement of the bipolar pulses expected to originate from neutrino interactions.
|
AGATA Collaboration(Soderstrom, P. A. et al), & Gadea, A. (2011). Interaction position resolution simulations and in-beam measurements of the AGATA HPGe detectors. Nucl. Instrum. Methods Phys. Res. A, 638(1), 96–109.
Abstract: The interaction position resolution of the segmented HPGe detectors of an AGATA triple cluster detector has been studied through Monte Carlo simulations and in an in-beam experiment. A new method based on measuring the energy resolution of Doppler-corrected gamma-ray spectra at two different target to detector distances is described. This gives the two-dimensional position resolution in the plane perpendicular to the direction of the emitted gamma-ray. The gamma-ray tracking was used to determine the full energy of the gamma-rays and the first interaction point, which is needed for the Doppler correction. Five different heavy-ion induced fusion-evaporation reactions and a reference reaction were selected for the simulations. The results of the simulations show that the method works very well and gives a systematic deviation of <1 mm in the FVVHM of the interaction position resolution for the gamma-ray energy range from 60 keV to 5 MeV. The method was tested with real data from an in-beam measurement using a (30)5i beam at 64 MeV on a thin C-12 target. Pulse-shape analysis of the digitized detector waveforms and gamma-ray tracking was performed to determine the position of the first interaction point, which was used for the Doppler corrections. Results of the dependency of the interaction position resolution on the gamma-ray energy and on the energy, axial location and type of the first interaction point, are presented. The FVVHM of the interaction position resolution varies roughly linearly as a function of gamma-ray energy from 8.5 mm at 250 key to 4 mm at 1.5 MeV, and has an approximately constant value of about 4 mm in the gamma-ray energy range from 1.5 to 4 MeV.
|
BABAR Collaboration(del Amo Sanchez, P. et al), Lopez-March, N., Martinez-Vidal, F., Milanes, D. A., & Oyanguren, A. (2011). Search for the decay B-0 -> gamma gamma. Phys. Rev. D, 83(4), 032006–11pp.
Abstract: We report the result of a search for the rare decay B-0 -> gamma gamma in 426 fb(-1) of data, corresponding to 226 x 10(6) B-0(B) over bar (0) pairs, collected on the Y(4S) resonance at the PEP-II asymmetric-energy e(+)e(-) collider using the BABAR detector. We use a maximum likelihood fit to extract the signal yield and observe 21(-12)(+13) signal events with a statistical significance of 1.8 sigma. This corresponds to a branching fraction B(B-0 -> gamma gamma) = (1.7 +/- 1.1(stat.) +/- 0.2(syst.)) X 10(-7). Based on this result, we set a 90% confidence level upper limit of B(B-0 -> gamma gamma) < 3.2 X 10(-7).
|
CDF Collaboration(Aaltonen, T. et al), & Cabrera, S. (2011). Measurement of b Hadron Lifetimes in Exclusive Decays Containing a J/Psi in p(p)over-bar Collisions at sqrt(s)=1.96 TeV. Phys. Rev. Lett., 106(12), 121804–8pp.
Abstract: We report on a measurement of b-hadron lifetimes in the fully reconstructed decay modes B+-> J/psi K+, B-0 -> J/psi K*(892)(0), B-0 -> J/psi K-s(0), and Lambda(0)(b)-> J/psi Lambda(0) using data corresponding to an integrated luminosity of 4.3 fb(-1), collected by the CDF II detector at the Fermilab Tevatron. The measured lifetimes are tau(B+)=[1.639 +/- 0.009(stat)+/- 0.009(syst)]ps, tau(B-0)=[1.507 +/- 0.010(stat)+/- 0.008(syst)]ps, and tau(Lambda(0)(b))=[1.537 +/- 0.045(stat)+/- 0.014(syst)]ps. The lifetime ratios are tau(B+)/tau(B-0)=[1.088 +/- 0.009(stat)+/- 0.004(syst)] and tau(Lambda(0)(b))/tau(B-0)=[1.020 +/- 0.030(stat)+/- 0.008(syst)]. These are the most precise determinations of these quantities from a single experiment.
|