|
Oliver-Canamas, L., Vijande, J., Candela-Juan, C., Gimeno-Olmos, J., Pujades-Claumarchirant, M. C., Rovira-Escutia, J. J., et al. (2023). A User-Friendly System for Mailed Dosimetric Audits of Ir-192 or Co-60 HDR Brachytherapy Sources. Cancers, 15(9), 2484–14pp.
Abstract: Nowadays, the options available to perform external dosimetric audits of the high dose rate (HDR) brachytherapy treatment process are limited. In this work, we present a methodology that allows for performing dosimetric audits in this field. A phantom was designed and manufactured for this purpose. The criteria for its design, together with the in-house measurements for its characterization, are presented. The result is a user-friendly system that can be mailed to perform dosimetric audits in HDR brachytherapy on-site for systems using either Iridium-192 (Ir-192) or Cobalt-60 (Co-60) sources. Objectives: The main goal of this work is to design and characterize a user-friendly methodology to perform mailed dosimetric audits in high dose rate (HDR) brachytherapy for systems using either Iridium-192 (Ir-192) or Cobalt-60 (Co-60) sources. Methods: A solid phantom was designed and manufactured with four catheters and a central slot to place one dosimeter. Irradiations with an Elekta MicroSelectron V2 for Ir-192, and with a BEBIG Multisource for Co-60 were performed for its characterization. For the dose measurements, nanoDots, a type of optically stimulated luminescent dosimeters (OSLDs), were characterized. Monte Carlo (MC) simulations were performed to evaluate the scatter conditions of the irradiation set-up and to study differences in the photon spectra of different Ir-192 sources (Microselectron V2, Flexisource, BEBIG Ir2.A85-2 and Varisource VS2000) reaching the dosimeter in the irradiation set-up. Results: MC simulations indicate that the surface material on which the phantom is supported during the irradiations does not affect the absorbed dose in the nanoDot. Generally, differences below 5% were found in the photon spectra reaching the detector when comparing the Microselectron V2, the Flexisource and the BEBIG models. However, differences up to 20% are observed between the V2 and the Varisource VS2000 models. The calibration coefficients and the uncertainty in the dose measurement were evaluated. Conclusions: The system described here is able to perform dosimetric audits in HDR brachytherapy for systems using either Ir-192 or Co-60 sources. No significant differences are observed between the photon spectra reaching the detector for the MicroSelectron V2, the Flexisource and the BEBIG Ir-192 sources. For the Varisource VS2000, a higher uncertainty is considered in the dose measurement to allow for the nanoDot response.
|
|
|
Beltran-Palau, P., del Rio, A., & Navarro-Salas, J. (2023). Quantum corrections to the Schwarzschild metric from vacuum polarization. Phys. Rev. D, 107(8), 085023–15pp.
Abstract: We explore static and spherically symmetric solutions of the 4-dimensional semiclassical Einstein's equations using the quantum vacuum polarization of a conformal field as a source. These solutions may be of interest for the study of exotic compact objects (ECOs). The full backreaction problem is addressed by solving the semiclassical Tolman-Oppenheimer-Volkoff (TOV) equations making use of effective equations of state inspired by the trace anomaly and an extra simplifying and reasonable assumption. We combine analytical and numerical techniques to solve the resulting differential equations, both perturbatively and nonperturbatively in h. In all cases the solution is similar to the Schwarzschild metric up p ffiffito the vicinity of the classical horizon r = 2M. However, at r = 2M + epsilon, with epsilon similar to O(root h), we find a coordinate singularity. In the case of matching with a static star, this leads to an upper bound in the compactness, and sets a constraint on the family of stable ECOs. We also study the corrections that the quantum-vacuum polarization induces on the propagation of waves, and discuss the implications. For the pure vacuum case, we can further extend the solution by using appropriate coordinates until we reach another singular point, where this time a null curvature singularity arises and prevents extending beyond. This picture qualitatively agrees with the results obtained in the effective two-dimensional approach, and reinforces the latter as a reasonable method.
|
|
|
Vatsyayan, D., & Goswami, S. (2023). Lowering the scale of fermion triplet leptogenesis with two Higgs doublets. Phys. Rev. D, 107(3), 035014–9pp.
Abstract: In this paper, we consider the possibility of generating the observed baryon asymmetry of the Universe via leptogenesis in the context of a triplet fermion-mediated type-III seesaw model of neutrino mass. With a hierarchical spectrum of the additional fermions, the lower bound on the lightest triplet mass is similar to 1010 GeV for successful leptogenesis, a couple of orders higher than that of the type-I case. We investigate the possibility of lowering this bound in the framework of two-Higgs-doublet models. We find that the bounds can be lowered down to 107 GeV for a hierarchical spectrum. If we include the flavor effects, then a further lowering by one order of magnitude is possible. We also discuss if such lowering can be compatible with the naturalness bounds on the triplet mass.
|
|
|
ANTARES Collaboration(Albert, A. et al), Alves, S., Calvo, D., Carretero, V., Gozzini, R., Hernandez-Rey, J. J., et al. (2023). Search for neutrino counterparts to the gravitational wave sources from LIGO/Virgo O3 run with the ANTARES detector. J. Cosmol. Astropart. Phys., 04(4), 004–19pp.
Abstract: Since 2015 the LIGO and Virgo interferometers have detected gravitational waves from almost one hundred coalescences of compact objects (black holes and neutron stars). This article presents the results of a search performed with data from the ANTARES telescope to identify neutrino counterparts to the gravitational wave sources detected during the third LIGO/Virgo observing run and reported in the catalogues GWTC-2, GWTC-2.1, and GWTC-3. This search is sensitive to all-sky neutrinos of all flavours and of energies > 100 GeV, thanks to the inclusion of both track-like events (mainly induced by v μcharged -current interactions) and shower-like events (induced by other interaction types). Neutrinos are selected if they are detected within +/- 500 s from the GW merger and with a reconstructed direction compatible with its sky localisation. No significant excess is found for any of the 80 analysed GW events, and upper limits on the neutrino emission are derived. Using the information from the GW catalogues and assuming isotropic emission, upper limits on the total energy Etot,v emitted as neutrinos of all flavours and on the ratio fv = Etot,v/EGW between neutrino and GW emissions are also computed. Finally, a stacked analysis of all the 72 binary black hole mergers (respectively the 7 neutron star-black hole merger candidates) has been performed to constrain the typical neutrino emission within this population, leading to the limits: Etot,v < 4.0 x 1053 erg and fv < 0.15 (respectively, Etot,v < 3.2 x 1053 erg and fv < 0.88) for E-2 spectrum and isotropic emission. Other assumptions including softer spectra and non-isotropic scenarios have also been tested.
|
|
|
Belchior, F. M., Moreira, A. R. P., Maluf, R. V., & Almeida, C. A. S. (2023). Localization of abelian gauge fields with Stueckelberg-like geometrical coupling on f(T, B)-thick brane. Eur. Phys. J. C, 83(5), 388–14pp.
Abstract: In the context of f (T, B) modified teleparallel gravity, we investigate the influence of torsion scalar T and boundary term B on the confinement of both the gauge vector and Kalb-Ramond fields. Both fields require a suitable coupling in five-dimensional braneworld scenarios to yield a normalizable zero mode. We propose a Stueckelberg-like geometrical coupling that non-minimally couples the fields to the torsion scalar and boundary term. To set up our braneworld models, we use the first-order formalism in which two kinds of superpotential are taken: sine-Gordon and f(4)-deformed. The geometrical coupling is used to produce a localized zero mode. Moreover, we analyze the massive spectrum for both fields and obtain possible resonant massive modes. Furthermore, we do not find tachyonic modes leading to a consistent thick brane.
|
|