n_TOF Collaboration(Massimi, C. et al.), Domingo-Pardo, C., Giubrone, G., & Tain, J. L. (2017). Neutron spectroscopy of Mg-26 states: Constraining the stellar neutron source Ne-22(alpha, n)Mg-25. Phys. Lett. B, 768, 1–6.
Abstract: This work reports on accurate, high-resolution measurements of the Mg-25(n, gamma)Mg-26 and Mg-25(n, tot) cross sections in the neutron energy range from thermal to about 300 keV, leading to a significantly improved Mg-25(n, gamma)Mg-26 parametrization. The relevant resonances for n+Mg-25 were characterized from a combined R-matrix analysis of the experimental data. This resulted in an unambiguous spin/parity assignment of the corresponding excited states in Mg-26. With this information experimental upper limits of the reaction rates for Ne-22(alpha, n)Mg-25 and Ne-22(alpha, gamma)Mg-26 were established, potentially leading to a significantly higher (alpha, n)/(alpha, gamma) ratio than previously evaluated. The impact of these results has been studied for stellar models in the mass range 2 to 25 M-circle dot. (C) 2017 The Author(s). Published by Elsevier B.V.
|
Guerrero, C., Domingo-Pardo, C., Kappeler, F., Lerendegui-Marco, J., Palomo, F. R., Quesada, J. M., et al. (2017). Prospects for direct neutron capture measurements on s-process branching point isotopes. Eur. Phys. J. A, 53(5), 87–5pp.
Abstract: The neutron capture cross sections of several unstable key isotopes acting as branching points in the s-process are crucial for stellar nucleosynthesis studies, but they are very challenging to measure directly due to the difficult production of sufficient sample material, the high activity of the resulting samples, and the actual (n, gamma) measurement, where high neutron fluxes and effective background rejection capabilities are required. At present there are about 21 relevant s-process branching point isotopes whose cross section could not be measured yet over the neutron energy range of interest for astrophysics. However, the situation is changing with some very recent developments and upcoming technologies. This work introduces three techniques that will change the current paradigm in the field: the use of gamma-ray imaging techniques in (n,gamma) experiments, the production of moderated neutron beams using high-power lasers, and double capture experiments in Maxwellian neutron beams.
|
Ong, W. J. et al, & Domingo-Pardo, C. (2017). Low-lying level structure of Cu-56 and its implications for the rp process. Phys. Rev. C, 95(5), 055806–8pp.
Abstract: The low-lying energy levels of proton-rich Cu-56 have been extracted using in-beam gamma-ray spectroscopy with the state-of-the-art gamma-ray tracking array GRETINA in conjunction with the S800 spectrograph at the National Superconducting Cyclotron Laboratory at Michigan State University. Excited states in Cu-56 serve as resonances in the Ni-55(p,gamma)Cu-56 reaction, which is a part of the rp process in type-I x-ray bursts. To resolve existing ambiguities in the reaction Q value, a more localized isobaric multiplet mass equation (IMME) fit is used, resulting in Q = 639 +/- 82 keV. We derive the first experimentally constrained thermonuclear reaction rate for Ni-55(p,.) Cu-56. We find that, with this newrate, the rp processmay bypass the (56)Niwaiting point via the Ni-55(p,gamma) reaction for typical x-ray burst conditions with a branching of up to similar to 40%. We also identify additional nuclear physics uncertainties that need to be addressed before drawing final conclusions about the rp-process reaction flow in the Ni-56 region.
|
Caballero-Folch, R. et al, Domingo-Pardo, C., Agramunt, J., Algora, A., Rubio, B., & Tain, J. L. (2017). beta-decay half-lives and beta-delayed neutron emission probabilities for several isotopes of Au, Hg, Tl, Pb, and Bi, beyond N=126. Phys. Rev. C, 95(6), 064322–16pp.
Abstract: Background: There have been measurements on roughly 230 nuclei that are beta-delayed neutron emitters. They range from He-8 up to La-150. Apart from 210Tl, with a branching ratio of only 0.007%, no other neutron emitter has been measured beyond A = 150. Therefore, new data are needed, particularly in the region of heavy nuclei around N = 126, in order to guide theoretical models and help understand the formation of the third r-process peak at A similar to 195. Purpose: To measure both beta-decay half-lives and neutron branching ratios of several neutron-rich Au, Hg, Tl, Pb, and Bi isotopes beyond N = 126. Method: Ions of interest were produced by fragmentation of a U-238 beam, selected and identified via the GSI-FRS fragment separator. A stack of segmented silicon detectors (SIMBA) was used to measure ion implants and beta decays. An array of 30 He-3 tubes embedded in a polyethylene matrix (BELEN) was used to detect neutrons with high efficiency and selectivity. A self-triggered digital system is employed to acquire data and to enable time correlations. The latter were analyzed with an analytical model and results for the half-lives and neutron-branching ratios were derived by using the binned maximum-likelihood method. Results: Twenty new beta-decay half-lives are reported for Au204-206, Hg208-211, Tl211-216, Pb215-218, and Bi218-220, nine of them for the first time. Neutron emission probabilities are reported for Hg-210,Hg-211 and Tl211-216. Conclusions: The new beta-decay half-lives are in good agreement with previous measurements on nuclei in this region. The measured neutron emission probabilities are comparable to or smaller than values predicted by global models such as relativistic Hartree Bogoliubov plus the relativistic quasi-particle random phase approximation (RHB + RQRPA).
|
BRIKEN Collaboration(Tarifeño-Saldivia, A. et al), Tain, J. L., Domingo-Pardo, C., Agramunt, J., Algora, A., Morales, A. I., et al. (2017). Conceptual design of a hybrid neutron-gamma detector for study of beta-delayed neutrons at the RIB facility of RIKEN. J. Instrum., 12, P04006–22pp.
Abstract: BRIKEN is a complex detection system to be installed at the RIB-facility of the RIKEN Nishina Center. It is aimed at the detection of heavy-ion implants, β-particles, γ-rays and β-delayed neutrons. The whole detection setup involves the Advanced Implantation Detection Array (AIDA), two HPGe Clover detectors and a large set of 166 counters of 3He embedded in a high-density polyethylene matrix. This article reports on a novel methodology developed for the conceptual design and optimisation of the 3He-tubes array, aiming at the best possible performance in terms of neutron detection. The algorithm is based on a geometric representation of two selected parameters of merit, namely, average neutron detection efficiency and efficiency flatness, as a function of a reduced number of geometric variables. The response of the detection system itself, for each configuration, is obtained from a systematic MC-simulation implemented realistically in Geant4. This approach has been found to be particularly useful. On the one hand, due to the different types and large number of 3He-tubes involved and, on the other hand, due to the additional constraints introduced by the ancillary detectors for charged particles and gamma-rays. Empowered by the robustness of the algorithm, we have been able to design a versatile detection system, which can be easily re-arranged into a compact mode in order to maximize the neutron detection performance, at the cost of the gamma-ray sensitivity. In summary, we have designed a system which shows, for neutron energies up to 1(5) MeV, a rather flat and high average efficiency of 68.6%(64%) and 75.7%(71%) for the hybrid and compact modes, respectively. The performance of the BRIKEN system has been also quantified realistically by means of MC-simulations made with different neutron energy distributions.
|