|
Molina, F. et al, Rubio, B., Agramunt, J., Algora, A., Domingo-Pardo, C., Gadea, A., et al. (2015). T-z =-1 -> 0 beta decays of Ni-54, Fe-50, Cr-46, and Ti-42 and comparison with mirror (He-3,t) measurements. Phys. Rev. C, 91(1), 014301–19pp.
Abstract: We have studied the beta decay of the T-z = -1, f(7/2) shell nuclei Ni-54, Fe-50, Cr-46, and Ti-42 produced in fragmentation reactions. The proton separation energies in the daughter T-z = 0 nuclei are relatively large (approximate to 4-5 MeV) so studies of the. rays are essential. The experiments were performed at GSI as part of the Stopped-beam campaign with the RISING setup consisting of 15 Euroball Cluster Ge detectors. From the newly obtained high precision beta-decay half-lives, excitation energies, and beta branching ratios, we were able to extract Fermi and Gamow-Teller transition strengths in these beta decays. With these improved results it was possible to compare in detail the Gamow-Teller (GT) transition strengths observed in beta decay including a sensitivity limit with the strengths of the T-z = +1 to T-z = 0 transitions derived from high resolution (He-3,t) reactions on the mirror target nuclei at RCNP, Osaka. The accumulated B(GT) strength obtained from both experiments looks very similar although the charge exchange reaction provides information on a broader energy range. Using the “merged analysis” one can obtain a full picture of the B(GT) over the full Q(beta) range. Looking at the individual transitions some differences are observed, especially for the weak transitions. Their possible origins are discussed.
|
|
|
Modamio, V., Valiente-Dobon, J. J., Jaworski, G., Huyuk, T., Triossi, A., Egea, J., et al. (2015). Digital pulse-timing technique for the neutron detector array NEDA. Nucl. Instrum. Methods Phys. Res. A, 775, 71–76.
Abstract: A new digital pulse-timing algorithm, to be used with the future neutron detector array NEDA, has been developed and tested. The time resolution of four 5 in diameter photomultiplier tubes (XP4512, R4144, R11833-100, and ET9390-kb), coupled to a cylindrical 5 in by 5 in BC501A liquict scintillator detector was measured by employing digital sampling electronics and a constant fraction discriminator (CFD) algorithm. The zero crossing of the CM algorithm was obtained with a cubic spline interpolation, which was continuous up to the second derivative. The performance of the algorithm was studied at sampling rates of 500 MS/s and 200 MS/s. The time resolution obtained with the digital electronics was compared to the values acquired with a standard analog CFD. The result of this comparison shows that the time resolution from the analog and the digital measurements at 500 MS/s and at 200 MS/s are within 15% for all the tested photomultiplier tubes.
|
|
|
AGATA Collaboration(Crespi, F. C. L. et al), & Gadea, A. (2015). 1(-) and 2(+) discrete states in Zr-90 populated via the (O-17, O-17 'gamma) reaction. Phys. Rev. C, 91(2), 024323–9pp.
Abstract: 2(+) and 1(-) states in Zr-90 were populated via the (O-17, O-17 'gamma) reaction at 340 MeV. The gamma decay was measured with high resolution using the AGATA (advanced gamma tracking array demonstrator array). Differential cross sections were obtained at few different angles for the scattered particle. The results of the elastic scattering and inelastic excitation of 2(+), 3(,)(-) and 1(-) states are compared with distorted-wave Born approximation (DWBA) calculations, using both the standard collective form factor and a form factor obtained by folding microscopically calculated transition densities. This allowed to extract the isoscalar component of the 1(-) state at 6.424 MeV. The comparison of the present (17O, 17O 'gamma) data with existing (gamma,gamma') and (p, p') data in the corresponding region of the gamma continuum (6-11 MeV), characterized by a large E1 component, shows completely different behaviors of the cross section as a function of the nuclear excitation energy. The comparison of the data with DWBA calculations suggests a decrease of the isoscalar strength in the cross section with increasing excitation energy.
|
|
|
AGATA Collaboration(Sahin, E. et al), Gadea, A., & Huyuk, T. (2015). Shell evolution beyond N=40: Cu-69,Cu-71,Cu-73. Phys. Rev. C, 91(3), 034302–9pp.
Abstract: The level structure of the neutron-rich Cu-69, Cu-71, and Cu-73 isotopes has been investigated by means of multinucleon transfer reactions. The experiment was performed at Laboratori Nazionali di Legnaro using the AGATA Demonstrator array coupled to the PRISMA magnetic spectrometer. Lifetimes of excited states in Cu nuclei were measured with the recoil-distance Doppler-shift method. The resulting electromagnetic matrix elements for transitions from excited states in Cu-69,Cu-71,Cu-73 nuclei are used to assess the collective or single-particle character of these states. The results are compared with predictions of large-scale shell-model calculations, giving further insight into the evolution of the proton pf shell as neutrons fill the 1g(9/2) orbital.
|
|
|
PreSPEC and AGATA Collaborations(Ralet, D. et al), & Gadea, A. (2015). Data-flow coupling and data-acquisition triggers for the PreSPEC-AGATA campaign at GSI. Nucl. Instrum. Methods Phys. Res. A, 786, 32–39.
Abstract: The PreSPEC setup for high-resolution 'gamma-ray spectroscopy using radioactive ion beams was employed for experimental campaigns in 2012 and 2014. The setup consisted of the state of the art Advanced GAmma Tracking Array (AGATA) and the High Energy gamma cleteCTOR (HECTOR+) positioned around a secondary target at the final focal plane of the GSI FRagment Separator (FRS) to perform in-beam gamma-ray spectroscopy of exotic nuclei. The Lund York Cologne CAlorimeter (LYCCA) was used to identify the reaction products. In this paper we report on the trigger scheme used during the campaigns. The dataflow coupling between the Multi-Branch System (MBS) based Data AcQuisition (DAQ) used for FRS-LYCCA and the “Nouvelle Acquisition temps Reel Version 1.2 Avec Linux” (NARVAL) based acquisition system used for AGATA are also described.
|
|
|
Bizzeti, P. G., Sona, P., Michelagnoli, C., Melon, B., Bazzacco, D., Farnea, E., et al. (2015). Analyzing power of AGATA triple clusters for gamma-ray linear polarization. Eur. Phys. J. A, 51(4), 49–11pp.
Abstract: We have investigated the ability of AGATA triple clusters to measure the linear polarization of gamma rays, exploiting the azimuthal-angle dependence of the Compton scattering differential cross section. To this aim, partially polarized gamma rays have been produced by Coulomb excitation of the first excited state of Pd-104 and Pd-108, which decay to the ground state by emission of gamma rays of 555.8 keV and 433.9 keV, respectively. Pulse-shape analysis and gamma-ray tracking techniques have been used to determine the position and time sequence of the interaction points inside the germanium crystals. Anisotropies in the detection efficiency have been taken into account using 661.6 keV gammas from a Cs-137 radioactive source. We obtain an average analyzing power of 0.451(34) at 433.9 keV and 0.484(24) at 555.8 keV.
|
|
|
Mijatovic, T., Szilner, S., Corradi, L., Montanari, D., Courtin, S., Fioretto, E., et al. (2015). Pairing Correlation Study in the 40Ar + 208Pb Multinucleon Transfer Reaction. Acta Phys. Pol. B, 46(3), 439–442.
Abstract: The Ar-40 + Pb-208 multinucleon transfer reaction has been studied at E-lab = 255 MeV with the large solid angle magnetic spectrometer PRISMA. Mass and charge yields, differential and total cross sections, total kinetic energy loss distributions of different channels were simultaneously measured. Angular distributions were measured in a wide angular range by matching different spectrometer angular settings. Absolute cross sections were obtained by careful evaluation of the spectrometer response function. These cross sections for different transfer channels allow the discussion of the role played by nucleon-nucleon correlations.
|
|
|
AGATA Collaboration(Alexander, T. et al), & Gadea, A. (2015). Isomeric ratios in Hg-206. Acta Phys. Pol. B, 46(3), 601–605.
Abstract: Hg-206 was populated in the fragmentation of an E/A = 1 GeV Pb-208 beam at GSI. It was part of a campaign to study nuclei around Pb-208 via relativistic Coulomb excitation. The observation of the known isomeric states confirmed the identification of the fragmentation products. The isomeric decays were also used to prove that the correlations between beam identification detectors and the AGATA gamma-ray tracking array worked properly and that the tracking efficiency was independent of the time relative to the prompt flash.
|
|
|
Taprogge, J. et al, Gadea, A., & Montaner-Piza, A. (2015). beta decay of Cd-129 and excited states in In-129. Phys. Rev. C, 91(5), 054324–11pp.
Abstract: The beta decay of Cd-129, produced in the relativistic fission of a U-238 beam, was experimentally studied at the RIBF facility at the RIKEN Nishina Center. From the gamma radiation emitted after the beta decays, a level scheme of In-129 was established comprising 31 excited states and 69 gamma-ray transitions. The experimentally determined level energies are compared to state-of-the-art shell-model calculations. The half-lives of the two beta-decaying states in Cd-129 were deduced and the beta feeding to excited states in In-129 were analyzed. It is found that, as in most cases in the Z < 50, N <= 82 region, both decays are dominated by the nu 0g(7/2) -> pi 0g(9/2) Gamow-Teller transition, although the contribution of first-forbidden transitions cannot be neglected.
|
|
|
Egea Canet, F. J. et al, Gadea, A., & Huyuk, T. (2015). A New Front-End High-Resolution Sampling Board for the New-Generation Electronics of EXOGAM2 and NEDA Detectors. IEEE Trans. Nucl. Sci., 62(3), 1056–1062.
Abstract: This paper presents the final design and results of the FADC Mezzanine for the EXOGAM (EXOtic GAMma array spectrometer) and NEDA (Neutron Detector Array) detectors. The measurements performed include those of studying the effective number of bits, the energy resolution using HP-Ge detectors, as well as timing histograms and discrimination performance. Finally, the conclusion shows how a common digitizing device has been integrated in the experimental environment of two very different detectors which combine both low-noise acquisition and fast sampling rates. Not only the integration fulfilled the expected specifications on both systems, but it also showed how a study of synergy between detectors could lead to the reduction of resources and time by applying a common strategy.
|
|