BABAR Collaboration(Lees, J. P. et al), Lopez-March, N., Martinez-Vidal, F., & Oyanguren, A. (2012). Search for the decay D-0 -> gamma gamma and measurement of the branching fraction for D-0 -> pi(0)pi(0). Phys. Rev. D, 85(9), 091107–8pp.
Abstract: We search for the rare decay of the D-0 meson to two photons, D-0 -> gamma gamma, and present a measurement of the branching fraction for a D-0 meson decaying to two neutral pions, B(D-0 -> pi(0)pi(0)). The data sample analyzed corresponds to an integrated luminosity of 470.5 fb(-1) collected by the BABAR detector at the PEP-II asymmetric-energy e(+)e(-) collider at SLAC. We place an upper limit on the branching fraction, B(D-0 -> gamma gamma) < 2.2 x 10(-6), at 90% confidence level. This limit improves on the existing limit by an order of magnitude. We also find B(D-0 -> pi(0)pi(0)) = (8.4 +/- 0.1 +/- 0.4 +/- 0.3 +/-) x 10(-4).
|
BABAR Collaboration(Lees, J. P. et al), Lopez-March, N., Martinez-Vidal, F., & Oyanguren, A. (2012). Cross sections for the reactions e(+)e(-) -> K+K-pi(+)pi(-), K+K-pi(0)pi(0), and K+K-K+K- measured using initial-state radiation events. Phys. Rev. D, 86(1), 012008–34pp.
Abstract: We study the processes e(+)e(-) -> K+K-pi(+)pi(-)gamma, K+K-pi(0)pi(0)gamma, and K+K-K+K-gamma, where the photon is radiated from the initial state. About 84000, 8000, and 4200 fully reconstructed events, respectively, are selected from 454 fb(-1) of BABAR data. The invariantmass of the hadronic final state defines the e(+)e(-) center-of- mass energy, so that the K+K-pi(+)pi(-)gamma data can be compared with direct measurements of the e(+)e(-) -> K+K-pi(+)pi(-) reaction. No directmeasurements exist for the e(+)e(-) -> K+K-pi(0)pi(0) or e(+)e(-) -> K+K-K+K- reactions, andwe present an update of our previous result based on a data sample that is twice as large. Studying the structure of these events, we find contributions froma number of intermediate states and extract their cross sections. In particular, we perform a more detailed study of the e(+)e(-) -> phi(1020)pi pi gamma reaction and confirm the presence of the Y(2175) resonance in the phi(1020)integral(0)(980) and K+K-integral(0)(980) modes. In the charmonium region, we observe the J/psi in all three final states and in several intermediate states, as well as the psi(2S) in some modes, and measure the corresponding products of branching fraction and electron width.
|
BABAR Collaboration(Aubert, B. et al), Azzolini, V., Lopez-March, N., Martinez-Vidal, F., Milanes, D. A., & Oyanguren, A. (2013). The BABAR detector: Upgrades, operation and performance. Nucl. Instrum. Methods Phys. Res. A, 729, 615–701.
Abstract: The BABAR detector operated successfully at the PEP-Il asymmetric e(+) e(-) collider at the SLAC National Accelerator Laboratory from 1999 to 2008. This report covers upgrades, operation, and performance of the collider and the detector systems, as well as the trigger, online and offline computing, and aspects of event reconstruction since the beginning of data taking.
|
Bevan, A. J. et al, Martinez-Vidal, F., Pich, A., Azzolini, V., Bernabeu, J., Lopez-March, N., et al. (2014). The Physics of the B Factories. Eur. Phys. J. C, 74(11), 3026–916pp.
|
NEXT Collaboration(Cebrian, S. et al), Alvarez, V., Carcel, S., Cervera-Villanueva, A., Diaz, J., Ferrario, P., et al. (2015). Radiopurity assessment of the tracking readout for the NEXT double beta decay experiment. J. Instrum., 10, P05006–16pp.
Abstract: The “Neutrino Experiment with a Xenon Time-Projection Chamber” (NEXT) is intended to investigate the neutrinoless double beta decay of Xe-136, which requires a severe suppression of potential backgrounds; therefore, an extensive screening and selection process is underway to control the radiopurity levels of the materials to be used in the experimental set-up of NEXT. The detector design combines the measurement of the topological signature of the event for background discrimination with the energy resolution optimization. Separate energy and tracking readout planes are based on different sensors: photomultiplier tubes for calorimetry and silicon multi-pixel photon counters for tracking. The design of a radiopure tracking plane, in direct contact with the gas detector medium, was specially challenging since the needed components like printed circuit boards, connectors, sensors or capacitors have typically, according to available information in databases and in the literature, activities too large for experiments requiring ultra-low background conditions. Here, the radiopurity assessment of tracking readout components based on gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterraneo de Canfranc (Spain) is described. According to the obtained results, radiopure enough printed circuit boards made of kapton and copper, silicon photomultipliers and other required components, fulfilling the requirement of an overall background level in the region of interest of at most 8 x 10(-4) counts keV(-1) kg(-1) y(-1), have been identified.
|