|
Esposito, R. et al, & Domingo-Pardo, C. (2021). Design of the third-generation lead-based neutron spallation target for the neutron time-of-flight facility at CERN. Phys. Rev. Accel. Beams, 24(9), 093001–17pp.
Abstract: The neutron time-of-flight (n_TOF) facility at the European Laboratory for Particle Physics (CERN) is a pulsed white-spectrum neutron spallation source producing neutrons for two experimental areas: the Experimental Area 1 (EAR1), located 185 m horizontally from the target, and the Experimental Area 2 (EAR2), located 20 m above the target. The target, based on pure lead, is impacted by a high-intensity 20-GeV/c pulsed proton beam. The facility was conceived to study neutron-nucleus interactions for neutron kinetic energies between a few meV to several GeV, with applications of interest for nuclear astrophysics, nuclear technology, and medical research. After the second-generation target reached the end of its lifetime, the facility underwent a major upgrade during CERN's Long Shutdown 2 (LS2, 2019-2021), which included the installation of the new third-generation neutron target. The first- and second-generation targets were based on water-cooled massive lead blocks and were designed focusing on EAR1, since EAR2 was built later. The new target is cooled by nitrogen gas to avoid erosion-corrosion and contamination of cooling water with radioactive lead spallation products. Moreover, the new design is optimized also for the vertical flight path and EAR2. This paper presents an overview of the target design focused on both physics and thermomechanical performance, and includes a description of the nitrogen cooling circuit and radiation protection studies.
|
|
|
n_TOF Collaboration(Lederer-Woods, C. et al.), Domingo-Pardo, C., & Tain, J. L. (2021). Destruction of the cosmic gamma-ray emitter Al-26 in massive stars: Study of the key Al-26(n, alpha) reaction. Phys. Rev. C, 104(3), L032803–6pp.
Abstract: Neutron destruction reactions of the cosmic gamma-ray emitter Al-26 are of importance to determine the amount of Al-26 ejected into our galaxy by supernova explosions and for Al-26 production in asymptotic giant branch stars. We performed a new measurement of the Al-26(n, alpha) reaction up to 160-keV neutron energy at the neutron time-of-flight facilities n_TOF at CERN and GELINA at EC-JRC. We provide strengths for ten resonances, six of them for the first time. We use our data to calculate astrophysical reactivities for stellar temperatures up to 0.7 GK. Our results resolve a discrepancy between the two previous direct measurements of this reaction, and indicate higher stellar destruction rates than the most recently recommended reactivity.
|
|
|
n_TOF Collaboration(Gawlik, A. et al), Domingo-Pardo, C., Tain, J. L., & Tarifeño-Saldivia, A. (2021). Measurement of the Ge-76(n, gamma) cross section at the n_TOF facility at CERN. Phys. Rev. C, 104(4), 044610–7pp.
Abstract: The Ge-76(n, gamma) reaction has been measured at the n_TOF facility at CERN via the time-of-flight technique. Neutron capture cross sections on Ge-76 are of interest to a variety of low-background experiments, such as neutrinoless double beta decay searches, and to nuclear astrophysics. We have determined resonance capture kernels up to 52 keV neutron energy and used the new data to calculate Maxwellian-averaged neutron capture cross sections for k(B)T values of 5 to 100 keV.
|
|
|
Fernandez, A. et al, Gadea, A., Perez-Vidal, R. M., Jurado, M., & Domingo-Pardo, C. (2021). Reinterpretation of excited states in Po-212: Shell-model multiplets rather than alpha-cluster states. Phys. Rev. C, 104(5), 054316–19pp.
Abstract: A gamma-ray spectroscopic study of Po-212 was performed at the Grand Accelerateur National d'Ions Lourds, using the inverse kinematics alpha-transfer reaction C-12(Pb-208, Po-212) Be-8 and the AGATA spectrometer. A careful analysis based on gamma gamma coincidence relations allowed us to establish 14 new excited states in the energy range between 1.9 and 3.3 MeV. None of these states, however, can be considered as candidates for the levels with spins and parities of 1(-) and 2(-) and excitation energies below 2.1 MeV, which have been predicted by recent alpha-cluster model calculations. A systematic comparison of the experimentally established excitation scheme of Po-212 with shell-model calculations was performed. This comparison suggests that the six states with excitation energies (spins and parities) of 1744 (4(-)), 1751 (8(-)), 1787 (6(-)), 1946 (4(-)), 1986 (8(-)), and 2016 (6(-)) keV, which previously were interpreted as alpha-cluster states, may in fact be of positive parity and belong to low-lying shell-model multiplets. This reinterpretation of the structure of Po-212 is supported by experimental information with respect to the linear polarization of gamma rays, which suggests a magnetic character of the 432-keV gamma ray decaying from the state at an excitation energy of 1787 keV to the 6(1)(+) yrast state, and exclusive reaction cross sections.
|
|
|
Lerendegui-Marco, J., Balibrea-Correa, J., Babiano-Suarez, V., Ladarescu, I., & Domingo-Pardo, C. (2022). Towards machine learning aided real-time range imaging in proton therapy. Sci Rep, 12(1), 2735–17pp.
Abstract: Compton imaging represents a promising technique for range verification in proton therapy treatments. In this work, we report on the advantageous aspects of the i-TED detector for proton-range monitoring, based on the results of the first Monte Carlo study of its applicability to this field. i-TED is an array of Compton cameras, that have been specifically designed for neutron-capture nuclear physics experiments, which are characterized by gamma-ray energies spanning up to 5-6 MeV, rather low gamma-ray emission yields and very intense neutron induced gamma-ray backgrounds. Our developments to cope with these three aspects are concomitant with those required in the field of hadron therapy, especially in terms of high efficiency for real-time monitoring, low sensitivity to neutron backgrounds and reliable performance at the high gamma-ray energies. We find that signal-to-background ratios can be appreciably improved with i-TED thanks to its light-weight design and the low neutron-capture cross sections of its LaCl3 crystals, when compared to other similar systems based on LYSO, CdZnTe or LaBr3. Its high time-resolution (CRT similar to 500 ps) represents an additional advantage for background suppression when operated in pulsed HT mode. Each i-TED Compton module features two detection planes of very large LaCl3 monolithic crystals, thereby achieving a high efficiency in coincidence of 0.2% for a point-like 1 MeV gamma-ray source at 5 cm distance. This leads to sufficient statistics for reliable image reconstruction with an array of four i-TED detectors assuming clinical intensities of 10(8) protons per treatment point. The use of a two-plane design instead of three-planes has been preferred owing to the higher attainable efficiency for double time-coincidences than for threefold events. The loss of full-energy events for high energy gamma-rays is compensated by means of machine-learning based algorithms, which allow one to enhance the signal-to-total ratio up to a factor of 2.
|
|