|
Boso, A. et al, Domingo-Pardo, C., & Perez-Vidal, R. M. (2019). Isospin dependence of electromagnetic transition strengths among an isobaric triplet. Phys. Lett. B, 797, 134835–6pp.
Abstract: Electric quadrupole matrix elements, M-p, for the J(pi) = 2(+) -> 0(+), Delta T = 0, T = 1 transitions across the A = 46 isobaric multiplet Cr-46-V-46-Ti-46 have been measured at GSI with the FRS-LYCCA-AGATA setup. This allows direct insight into the isospin purity of the states of interest by testing the linearity of M-p with respect to T-z. Pairs of nuclei in the T = 1 triplet were studied using identical reaction mechanisms in order to control systematic errors. The M-p values were obtained with two different methodologies: (i) a relativistic Coulomb excitation experiment was performed for Cr-46 and Ti-46; (ii) a “stretched target” technique was adopted here, for the first time, for lifetime measurements in V-46 and Ti-46. A constant value of M-p across the triplet has been observed. Shell-model calculations performed within the fp shell fail to reproduce this unexpected trend, pointing towards the need of a wider valence space. This result is confirmed by the good agreement with experimental data achieved with an interaction which allows excitations from the underlying sd shell. A test of the linearity rule for all published data on complete T = 1 isospin triplets is presented.
|
|
|
Guerrero, C., Tessler, M., Paul, M., Lerendegui-Marco, J., Heinitz, S., Maugeri, E. A., et al. (2019). The s-process in the Nd-Pm-Sm region: Neutron activation of Pm-147. Phys. Lett. B, 797, 134809–6pp.
Abstract: The Nd-Pm-Sm branching is of interest for the study of the s-process, related to the production of heavy elements in stars. As Sm-148 and Sm-150 are s-only isotopes, the understanding of the branching allows constraining the s-process neutron density. In this context the key physics input needed is the cross section of the three unstable nuclides in the region: Nd-147 (10.98 d half-life), Pm-147 (2.62 yr) and Pm-148 (5.37 d). This paper reports on the activation measurement of Pm-147, the longest-lived of the three nuclides. The cross section measurement has been carried out by activation at the SARAF LiLiT facility using a 56(2) μg target. Compared to the single previous measurement of Pm-147, the measurement presented herein benefits from a target 2000 times more massive. The resulting Maxwellian Averaged Cross Section (MACS) to the ground and metastable states in Pm-148 are 469(50) mb and 357(27) mb. These values are 41% higher (to the ground state) and 15% lower (to the metastable state) than the values reported so far, leading however to a total cross section of 826(107) mb consistent within uncertainties with the previous result and hence leaving unchanged the previous calculation of the s-process neutron density.
|
|
|
n_TOF Collaboration(Gawlik, A. et al), Domingo-Pardo, C., Tain, J. L., & Tarifeño-Saldivia, A. (2019). Measurement of the Ge-70(n, gamma) cross section up to 300 keV at the CERN n_TOF facility. Phys. Rev. C, 100(4), 045804–10pp.
Abstract: Neutron capture data on intermediate mass nuclei are of key importance to nucleosynthesis in the weak component of the slow neutron capture processes, which occurs in massive stars. The (n,gamma) cross section on Ge-70, which is mainly produced in the s process, was measured at the neutron time-of-flight facility n_TOF at CERN. Resonance capture kernels were determined up to 40 keV neutron energy and average cross sections up to 300 keV. Stellar cross sections were calculated from kT = 5 keV to kT = 100 keV and are in very good agreement with a previous measurement by Walter and Beer (1985) and recent evaluations. Average cross sections are in agreement with Walter and Beer (1985) over most of the neutron energy range covered, while they are systematically smaller for neutron energies above 150 keV. We have calculated isotopic abundances produced in s-process environments in a 25 solar mass star for two initial metallicities (below solar and close to solar). While the low metallicity model reproduces best the solar system germanium isotopic abundances, the close to solar model shows a good global match to solar system abundances in the range of mass numbers A = 60-80.
|
|
|
AGATA Collaboration(Goldkuhle, A. et al), Perez-Vidal, R. M., Domingo-Pardo, C., & Gadea, A. (2019). Lifetime measurements in Ti-52,Ti-54 to study shell evolution toward N=32. Phys. Rev. C, 100(5), 054317–12pp.
Abstract: Lifetimes of the excited states in the neutron-rich Ti-52,Ti-54 nuclei, produced in a multinucleon-transfer reaction, were measured by employing the Cologne plunger device and the recoil-distance Doppler-shift method. The experiment was performed at the Grand Accelerateur National d'Ions Lourds facility by using the Advanced Gamma Tracking Array for the gamma-ray detection, coupled to the large-acceptance variable mode spectrometer for an event-by-event particle identification. A comparison between the transition probabilities obtained from the measured lifetimes of the 2(1)(+) to 8(1)(+) yrast states in Ti-52,Ti-54 and that from the shell-model calculations based on the well-established GXPF1A, GXPF1B, and KB3G fp shell interactions support the N = 32 subshell closure. The B(E2) values for Ti-52 determined in this work are in disagreement with the known data, but are consistent with the predictions of the shell-model calculations and reduce the previously observed pronounced staggering across the even-even titanium isotopes.
|
|
|
Babiano, V., Balibrea, J., Caballero, L., Calvo, D., Ladarescu, I., Mira Prats, S., et al. (2020). First i-TED demonstrator: A Compton imager with Dynamic Electronic Collimation. Nucl. Instrum. Methods Phys. Res. A, 953, 163228–9pp.
Abstract: i-TED consists of both a total energy detector and a Compton camera primarily intended for the measurement of neutron capture cross sections by means of the simultaneous combination of neutron time-of-flight (TOF) and gamma-ray imaging techniques. TOF allows one to obtain a neutron-energy differential capture yield, whereas the imaging capability is intended for the discrimination of radiative background sources, that have a spatial origin different from that of the capture sample under investigation. A distinctive feature of i-TED is the embedded Dynamic Electronic Collimation (DEC) concept, which allows for a trade-off between efficiency and image resolution. Here we report on some general design considerations and first performance characterization measurements made with an i-TED demonstrator in order to explore its gamma-ray detection and imaging capabilities.
|
|