|
Clinthorne, N., Brzezinski, K., Chesi, E., Cochran, E., Grkovski, M., Grosicar, B., et al. (2013). Silicon as an unconventional detector in positron emission tomography. Nucl. Instrum. Methods Phys. Res. A, 699, 216–220.
Abstract: Positron emission tomography (PET) is a widely used technique in medical imaging and in studying small animal models of human disease. In the conventional approach, the 511 keV annihilation photons emitted from a patient or small animal are detected by a ring of scintillators such as LYSO read out by arrays of photodetectors. Although this has been successful in achieving similar to 5 mm FWHM spatial resolution in human studies and similar to 1 mm resolution in dedicated small animal instruments, there is interest in significantly improving these figures. Silicon, although its stopping power is modest for 511 keV photons, offers a number of potential advantages over more conventional approaches including the potential for high intrinsic spatial resolution in 3D. To evaluate silicon in a variety of PET “magnifying glass” configurations, an instrument was constructed that consists of an outer partial-ring of PET scintillation detectors into which various arrangements of silicon detectors are inserted to emulate dual-ring or imaging probe geometries. Measurements using the test instrument demonstrated the capability of clearly resolving point sources of Na-22 having a 1.5 mm center-to-center spacing as well as the 1.2 mm rods of a F-18-filled resolution phantom. Although many challenges remain, silicon has potential to become the PET detector of choice when spatial resolution is the primary consideration. (C) 2012 Elsevier B.V. All rights reserved.
|
|
|
Studen, A., Brzezinski, K., Chesi, E., Cindro, V., Clinthorne, N. H., Cochran, E., et al. (2013). Silicon detectors for combined MR-PET and MR-SPECT imaging. Nucl. Instrum. Methods Phys. Res. A, 702, 88–90.
Abstract: Silicon based devices can extend PET-MR and SPECT-MR imaging to applications, where their advantages in performance outweigh benefits of high statistical counts. Silicon is in many ways an excellent detector material with numerous advantages, among others: excellent energy and spatial resolution, mature processing technology, large signal to noise ratio, relatively low price, availability, versatility and malleability. The signal in silicon is also immune to effects of magnetic field at the level normally used in MR devices. Tests in fields up to 7 T were performed in a study to determine effects of magnetic field on positron range in a silicon PET device. The curvature of positron tracks in direction perpendicular to the field's orientation shortens the distance between emission and annihilation point of the positron. The effect can be fully appreciated for a rotation of the sample for a fixed field direction, compressing range in all dimensions. A popular Ga-68 source was used showing a factor of 2 improvement in image noise compared to zero field operation. There was also a little increase in noise as the reconstructed resolution varied between 2.5 and 1.5 mm. A speculative applications can be recognized in both emission modalities, SPECT and PET. Compton camera is a subspecies of SPECT, where a silicon based scatter as a MR compatible part could inserted into the MR bore and the secondary detector could operate in less constrained environment away from the magnet. Introducing a Compton camera also relaxes requirements of the radiotracers used, extending the range of conceivable photon energies beyond 140.5 keV of the Tc-99m. In PET, one could exploit the compressed sub-millimeter range of positrons in the magnetic field. To exploit the advantage, detectors with spatial resolution commensurate to the effect must be used with silicon being an excellent candidate. Measurements performed outside of the MR achieving spatial resolution below 1 mm are reported.
|
|
|
Deak, M. (2013). Estimation of saturation and coherence effects in the KGBJS equation – a non-linear CCFM equation. J. High Energy Phys., 07(7), 087–18pp.
Abstract: We solve the modified non-linear extension of the CCFM equation – KGBJS equation – numerically for certain initial conditions and compare the resulting dipole amplitudes with those obtained front solving the original CCFM equation and the BFKL and BK equations for the same initial conditions. We improve the low transversal momentum behaviour of the KGBJS equation by a small modification.
|
|
|
Bierenbaum, I., Buchta, S., Draggiotis, P., Malamos, I., & Rodrigo, G. (2013). Tree-loop duality relation beyond single poles. J. High Energy Phys., 03(3), 025–24pp.
Abstract: We develop the Tree-Loop Duality Relation for two- and three-loop integrals with multiple identical propagators (multiple poles). This is the extension of the Duality Relation for single poles and multi-loop integrals derived in previous publications. We prove a generalization of the formula for single poles to multiple poles and we develop a strategy for dealing with higher-order pole integrals by reducing them to single pole integrals using Integration By Parts.
|
|
|
ATLAS Collaboration(Aad, G. et al), Cabrera Urban, S., Castillo Gimenez, V., Costa, M. J., Fassi, F., Ferrer, A., et al. (2013). Dynamics of isolated-photon plus jet production in pp collisions at root s=7 TeV with the ATLAS detector. Nucl. Phys. B, 875(3), 483–535.
Abstract: The dynamics of isolated-photon plus jet production in pp collisions at a centre-of-mass energy of 7 TeV has been studied with the ATLAS detector at the LHC using an integrated luminosity of 37 pb(-1). Measurements of isolated-photon plus jet bin-averaged cross sections are presented as functions of photon transverse energy, jet transverse momentum and jet rapidity. In addition, the bin-averaged cross sections as functions of the difference between the azimuthal angles of the photon and the jet, the photon jet invariant mass and the scattering angle in the photon jet centre-of-mass frame have been measured. Next-to-leading-order QCD calculations are compared to the measurements and provide a good description of the data, except for the case of the azimuthal opening angle.
|
|
|
Zamiralov, V. S., Ozpineci, A., & Erkol, G. (2013). QCD sum rules for the coupling constants of vector mesons to octet baryons. Mosc. Univ. Phys. Bull., 68(3), 205–209.
Abstract: The QCD sum rules on the light cone proposed by Wang for the coupling constants of the rho meson are generalized to the vector mesons omega and phi and all octet baryons, the I >-hyperon included. A comparison with other results is given.
|
|
|
Hinarejos, M., Bañuls, M. C., & Perez, A. (2013). A Study of Wigner Functions for Discrete-Time Quantum Walks. J. Comput. Theor. Nanosci., 10(7), 1626–1633.
Abstract: We perform a systematic study of the discrete time Quantum Walk on one dimension using Wigner functions, which are generalized to include the chirality (or coin) degree of freedom. In particular, we analyze the evolution of the negative volume in phase space, as a function of time, for different initial states. This negativity can be used to quantify the degree of departure of the system from a classical state. We also relate this quantity to the entanglement between the coin and walker subspaces.
|
|
|
LHCb Collaboration(Aaij, R. et al), Oyanguren, A., & Ruiz Valls, P. (2013). Production of J/psi and Y mesons in pp collisions at root s=8 TeV. J. High Energy Phys., 06(6), 064–31pp.
Abstract: The production of J/psi and gamma mesons in pp collisions at root s = 8 TeV is studied with the LHCb detector. The J/psi and gamma mesons are reconstructed in the mu(+)mu(-) decay mode and the signal yields are determined with a fit to the mu(+)mu(-) invariant mass distributions. The analysis is performed in the rapidity range 2.0 < y < 4.5 and transverse momentum range 0 < PT < 14 (15) GeV/c of the J/psi (gamma) mesons. The J/psi and gamma production cross-sections and the fraction of J/psi mesons from b-hadron decays are measured as a function of the meson P-T and y.
|
|
|
NEXT Collaboration(Alvarez, V. et al), Carcel, S., Cervera-Villanueva, A., Diaz, J., Ferrario, P., Gil, A., et al. (2013). Radiopurity control in the NEXT-100 double beta decay experiment: procedures and initial measurements. J. Instrum., 8, T01002–19pp.
Abstract: The “Neutrino Experiment with a Xenon Time-Projection Chamber” (NEXT) is intended to investigate the neutrinoless double beta decay of Xe-136, which requires a severe suppression of potential backgrounds. An extensive screening and material selection process is underway for NEXT since the control of the radiopurity levels of the materials to be used in the experimental set-up is a must for rare event searches. First measurements based on Glow Discharge Mass Spectrometry and gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterraneo de Canfranc (Spain) are described here. Activity results for natural radioactive chains and other common radionuclides are summarized, being the values obtained for some materials like copper and stainless steel very competitive. The implications of these results for the NEXT experiment are also discussed.
|
|
|
LHCb Collaboration(Aaij, R. et al), Oyanguren, A., & Ruiz Valls, P. (2013). Differential branching fraction and angular analysis of the decay B-s(0) -> phi mu(+)mu(-). J. High Energy Phys., 07(7), 084–18pp.
Abstract: The determination of the differential branching fraction and the first angular analysis of the decay B-s(0) -> phi mu(+)mu(-) are presented using data, corresponding to an integrated luminosity of 1.0 fb(-1), collected by the LHCb experiment at root s = 7 TeV. The differential branching fraction is determined in bins of q(2), the invariant dimuon mass squared. Integration over the full q2 range yields a total branching fraction of B(B-s(0) -> phi mu(+)mu(-)) = (7.07(-0.59)(+0.64) +/- 0.17 +/- 0.71) x 10(-7), where the first uncertainty is statistical, the second systematic, and the third originates from the branching fraction of the normalisation channel. An angular analysis is performed to determine the angular observables F-L, S-3, A(6), and A(9). The observables are consistent with Standard Model expectations.
|
|