Amjad, M. S., Bilokin, S., Boronat, M., Doublet, P., Frisson, T., Garcia Garcia, I., et al. (2015). A precise characterisation of the top quark electro-weak vertices at the ILC. Eur. Phys. J. C, 75(10), 512–11pp.
Abstract: Top quark production in the process e(+)e(-) -> t t at a future linear electron positron collider with polarised beams is a powerful tool to determine indirectly the scale of new physics. The presented study, based on a detailed simulation of the ILD detector concept, assumes a centre-of-mass energy of root s = 500GeV and a luminosity of L = 500 fb(-1) equally shared between the incoming beam polarisations of Pe-, Pe+ = +/- 0.8, -/+ 0.3. Events are selected in which the top pair decays semi-leptonically and the cross sections and the forward-backward asymmetries are determined. Based on these results, the vector, axial vector and tensorial CP conserving couplings are extracted separately for the photon and the Z(0) component. With the expected precision, a large number of models in which the top quark acts as a messenger to new physics can be distinguished with many standard deviations. This will dramatically improve expectations from e.g. the LHC for electro-weak couplings of the top quark.
|
Egea Canet, F. J. et al, Gadea, A., & Huyuk, T. (2015). A New Front-End High-Resolution Sampling Board for the New-Generation Electronics of EXOGAM2 and NEDA Detectors. IEEE Trans. Nucl. Sci., 62(3), 1056–1062.
Abstract: This paper presents the final design and results of the FADC Mezzanine for the EXOGAM (EXOtic GAMma array spectrometer) and NEDA (Neutron Detector Array) detectors. The measurements performed include those of studying the effective number of bits, the energy resolution using HP-Ge detectors, as well as timing histograms and discrimination performance. Finally, the conclusion shows how a common digitizing device has been integrated in the experimental environment of two very different detectors which combine both low-noise acquisition and fast sampling rates. Not only the integration fulfilled the expected specifications on both systems, but it also showed how a study of synergy between detectors could lead to the reduction of resources and time by applying a common strategy.
|
PreSPEC and AGATA Collaborations(Ralet, D. et al), & Gadea, A. (2015). Data-flow coupling and data-acquisition triggers for the PreSPEC-AGATA campaign at GSI. Nucl. Instrum. Methods Phys. Res. A, 786, 32–39.
Abstract: The PreSPEC setup for high-resolution 'gamma-ray spectroscopy using radioactive ion beams was employed for experimental campaigns in 2012 and 2014. The setup consisted of the state of the art Advanced GAmma Tracking Array (AGATA) and the High Energy gamma cleteCTOR (HECTOR+) positioned around a secondary target at the final focal plane of the GSI FRagment Separator (FRS) to perform in-beam gamma-ray spectroscopy of exotic nuclei. The Lund York Cologne CAlorimeter (LYCCA) was used to identify the reaction products. In this paper we report on the trigger scheme used during the campaigns. The dataflow coupling between the Multi-Branch System (MBS) based Data AcQuisition (DAQ) used for FRS-LYCCA and the “Nouvelle Acquisition temps Reel Version 1.2 Avec Linux” (NARVAL) based acquisition system used for AGATA are also described.
|
Aliaga, R. J., Herrero-Bosch, V., Capra, S., Pullia, A., Duenas, J. A., Grassi, L., et al. (2015). Conceptual design of the TRACE detector readout using a compact, dead time-less analog memory ASIC. Nucl. Instrum. Methods Phys. Res. A, 800, 34–39.
Abstract: The new TRacking Array for light Charged particle Ejectiles (TRACE) detector system requires monitorization and sampling of all pulses in a large number of channels with very strict space and power consumption restrictions for the front-end electronics and cabling, Its readout system is to be based on analog memory ASICs with 64 channels each that sample a 1 μs window of the waveform of any valid pulses at 200 MHz while discarding any other signals and are read out at 50 MHz with external ADC digitization. For this purpose, a new, compact analog memory architecture is described that allows pulse capture with zero dead time in any channel while vastly reducing the total number of storage cells, particularly for large amounts of input channels. This is accomplished by partitioning the typical Switched Capacitor Array structure into two pipelined, asymmetric stages and introducing FIFO queue-like control circuitry for captured data, achieving total independence between the capture and readout operations.
|
Clausse, A., Soto, L., & Tarifeño-Saldivia, A. (2015). Influence of the Anode Length on the Neutron Emission of a 50 J Plasma Focus: Modeling and Experiment. IEEE Trans. Plasma Sci., 43(2), 629–636.
Abstract: A comprehensive set of electric data measured in a small plasma focus (PF) device of 50 J correlated with the corresponding neutron emissions is taken as the base for developing a semiempirical model of the current sheet dynamics and the neutron yield. The model is able to explain the dependence of the neutron yield with the pressure and anode length with good accuracy, and suggests a physical interpretation of the drive parameter commonly used in PF design.
|