BABAR Collaboration(Aubert, B. et al), Azzolini, V., Lopez-March, N., Martinez-Vidal, F., Milanes, D. A., & Oyanguren, A. (2010). Measurement of vertical bar V-cb vertical bar and the Form-Factor Slope in (B)over-bar -> Dl(-) (nu)over-bar(l) Decays in Events Tagged by a Fully Reconstructed B Meson. Phys. Rev. Lett., 104(1), 011802–7pp.
Abstract: We present a measurement of the Cabibbo-Kobayashi-Maskawa matrix element vertical bar V-cb vertical bar and the form-factor slope rho(2) in (B) over bar -> Dl(-) (nu) over bar (l) decays based on 460 X 10(6) B (B) over bar events recorded at the Gamma(4S) resonance with the BABAR detector. (B) over bar -> Dl(-) (nu) over bar (l) decays are selected in events in which a hadronic decay of the second B meson is fully reconstructed. We measure B(B- -> D(0)l(-) (nu) over bar (l))/B(B- -> Xl(-) (nu) over bar (l)) = (0.255 +/- 0.009 +/- 0.009) and B((B) over bar (0) -> D(+)l(-) (nu) over bar (l))/B((B) over bar (0) -> Xl(-) (nu) over bar (l)) = (0.230 +/- 0.011 +/- 0.011), along with the differential decay distribution in (B) over bar -> Dl(-) (nu) over bar (l) decays. We then determine G(1)vertical bar V-cb vertical bar = 42.3 +/- 1.9 +/- 1.4) X 10(-3) and rho(2) = 1.20 +/- 0.09 +/- 0.04, where G(1) is the hadronic form factor at the point of zero recoil.
|
BABAR Collaboration(Aubert, B. et al), Azzolini, V., Lopez-March, N., Martinez-Vidal, F., Milanes, D. A., & Oyanguren, A. (2010). Searches for Lepton Flavor Violation in the Decays tau(+/-) -> e(+/-)gamma and tau(+/-) -> mu(+/-)gamma. Phys. Rev. Lett., 104(2), 021802–7pp.
Abstract: Searches for lepton-flavor-violating decays of a tau lepton to a lighter mass lepton and a photon have been performed with the entire data set of (963 +/- 7) x 10(6) tau decays collected by the BABAR detector near the Y(4S), Y(3S) and Y(2S) resonances. The searches yield no evidence of signals and we set upper limits on the branching fractions of B(tau(+/-) -> e(+/-)gamma) < 3.3 X 10(-8) and B(tau(+/-) -> mu(+/-)gamma) < 4.4 X 10(-8) at 90% confidence level.
|
Aristizabal Sierra, D., Bazzocchi, F., de Medeiros Varzielas, I., Merlo, L., & Morisi, S. (2010). Tri/Bi-maximal lepton mixing and leptogenesis. Nucl. Phys. B, 827(1-2), 34–58.
Abstract: In models with flavour symmetries added to the gauge group of the Standard Model the CP-violating asymmetry necessary for leptogenesis may be related with low-energy parameters. A particular case of interest is when the flavour symmetry produces exact Tri/Bi-maximal lepton mixing leading to a vanishing CP-violating asymmetry. In this paper we present a model-independent discussion that confirms this always occurs for unflavoured leptogenesis in type I see-saw scenarios, noting however that Tri/Bi-maximal mixing does not imply a vanishing asymmetry in general scenarios where there is interplay between type I and other see-saws. We also consider a specific model where the exact Tri/Bi-maximal mixing is lifted by corrections that can be parametrised by a small number of degrees of freedom and analyse in detail the existing link between low and high-energy parameters – focusing on how the deviations from Tri/Bi-maximal are connected to the parameters governing leptogenesis.
|
Aguiar, P., Rafecas, M., Ortuño, J. E., Kontaxakis, G., Santos, A., Pavia, J., et al. (2010). Geometrical and Monte Carlo projectors in 3D PET reconstruction. Med. Phys., 37(11), 5691–5702.
Abstract: Purpose: In the present work, the authors compare geometrical and Monte Carlo projectors in detail. The geometrical projectors considered were the conventional geometrical Siddon ray-tracer (S-RT) and the orthogonal distance-based ray-tracer (OD-RT), based on computing the orthogonal distance from the center of image voxel to the line-of-response. A comparison of these geometrical projectors was performed using different point spread function (PSF) models. The Monte Carlo-based method under consideration involves an extensive model of the system response matrix based on Monte Carlo simulations and is computed off-line and stored on disk. Methods: Comparisons were performed using simulated and experimental data of the commercial small animal PET scanner rPET. Results: The results demonstrate that the orthogonal distance-based ray-tracer and Siddon ray-tracer using PSF image-space convolutions yield better images in terms of contrast and spatial resolution than those obtained after using the conventional method and the multiray-based S-RT. Furthermore, the Monte Carlo-based method yields slight improvements in terms of contrast and spatial resolution with respect to these geometrical projectors. Conclusions: The orthogonal distance-based ray-tracer and Siddon ray-tracer using PSF image-space convolutions represent satisfactory alternatives to factorizing the system matrix or to the conventional on-the-fly ray-tracing methods for list-mode reconstruction, where an extensive modeling based on Monte Carlo simulations is unfeasible.
|
ATLAS Collaboration(Abat, E. et al), Castillo Gimenez, V., Ferrer, A., Gonzalez, V., Higon-Rodriguez, E., Mitsou, V. A., et al. (2010). Study of energy response and resolution of the ATLAS barrel calorimeter to hadrons of energies from 20 to 350 GeV. Nucl. Instrum. Methods Phys. Res. A, 621(1-3), 134–150.
Abstract: A fully instrumented slice of the ATLAS detector was exposed to test beams from the SPS (Super Proton Synchrotron) at CERN in 2004. In this paper, the results of the measurements of the response of the barrel calorimeter to hadrons with energies in the range 20-350 GeV and beam impact points and angles corresponding to pseudo-rapidity values in the range 0.2-0.65 are reported. The results are compared to the predictions of a simulation program using the Geant 4 toolkit.
|