|   | 
Details
   web
Records
Author HADES Collaboration (Agakishiev, G. et al); Diaz, J.; Gil, A.
Title Lambda-p femtoscopy in collisions of Ar + KCl at 1.76AGeV Type Journal Article
Year 2010 Publication Physical Review C Abbreviated Journal Phys. Rev. C
Volume 82 Issue 2 Pages 021901 - 5pp
Keywords (up)
Abstract Results on Lambda p femtoscopy are reported at the lowest energy so far. At a beam energy of 1.76AGeV, the reaction Ar + KCl was studied with the High Acceptance Di-Electron Spectrometer ( HADES) at SIS18/GSI. A high-statistics and high-purity Lambda sample was collected, allowing for the investigation of Lambda p correlations at low relative momenta. The experimental correlation function is compared to corresponding model calculations allowing the determination of the space-time extent of the Lambda p emission source. The Lambda p source radius is found to be slightly smaller than the pp correlation radius for a similar collision system. The present Lambda p radius is significantly smaller than that found for Au + Au/Pb + Pb collisions in the AGS, SPS, and RHIC energy domains but larger than that observed for electroproduction from He. Taking into account all available data, we find the Lambda p source radius to increase almost linearly with the number of participants to the power of one-third.
Address [Finocchiaro, P.] Ist Nazl Fis Nucl, Lab Nazl Sud, I-95125 Catania, Italy, Email: kotte@fzd.de
Corporate Author Thesis
Publisher Amer Physical Soc Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0556-2813 ISBN Medium
Area Expedition Conference
Notes ISI:000281017300001 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ elepoucu @ Serial 393
Permanent link to this record
 

 
Author HADES Collaboration (Agakishiev, G. et al); Diaz, J.; Gil, A.
Title Hyperon production in Ar plus KCl collisions at 1.76A GeV Type Journal Article
Year 2011 Publication European Physical Journal A Abbreviated Journal Eur. Phys. J. A
Volume 47 Issue 2 Pages 21 - 9pp
Keywords (up)
Abstract We present transverse momentum spectra, rapidity distribution and multiplicity of Lambda-hyperons measured with the HADES spectrometer in the reaction Ar(1.76A GeV) + KCl. The yield of Xi(-) is calculated from our previously reported Xi(-)/(Lambda+Sigma(0)) ratio and compared to other strange particle multiplicities. Employing a strangeness balance equation the multiplicities of the yet unmeasured Sigma(+/-)-hyperons can be estimated. Finally a statistical hadronization model is used to fit the yields of pi(-), K+, K-s(0), K-, phi, Lambda and Xi(-). The resulting chemical freeze-out temperature of T = (76 +/- 2) MeV is compared to the measured slope parameters obtained from fits to the transverse mass distributions of the different particles.
Address [Agakishiev, G.; Belyaev, A.; Chernenko, S.; Fateev, O.; Lapidus, K.; Zanevsky, Y.] Joint Inst Nucl Res, Dubna 141980, Russia, Email: Lorenz@Physik.uni-frankfurt.de
Corporate Author Thesis
Publisher Springer Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1434-6001 ISBN Medium
Area Expedition Conference
Notes ISI:000288551700007 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 540
Permanent link to this record
 

 
Author HADES Collaboration (Agakishiev, G. et al); Diaz, J.; Gil, A.
Title In-medium effects on K-0 mesons in relativistic heavy-ion collisions Type Journal Article
Year 2010 Publication Physical Review C Abbreviated Journal Phys. Rev. C
Volume 82 Issue 4 Pages 044907 - 9pp
Keywords (up)
Abstract We present the transverse momentum spectra and rapidity distributions of pi(-) and K-S(0) in Ar + KCl reactions at a beam kinetic energy of 1.756 A GeV measured with the High Acceptance Di-Electron Spectrometer (HADES). The reconstructed K-S(0) sample is characterized by good event statistics for a wide range in momentum and rapidity. We compare the experimental pi(-) and K-S(0) distributions to predictions by the Isospin Quantum Molecular Dynamics (IQMD) model. The model calculations show that K-S(0) at low transverse momenta constitute a particularly well-suited tool to investigate the kaon in-medium potential. Our K-S(0) data suggest a strong repulsive in-medium K-0 potential of about 40 MeV strength.
Address [Agakishiev, G.; Destefanis, M.; Gilardi, C.; Kirschner, D.; Kuehn, W.; Lange, J. S.; Metag, V.; Mishra, D.; Pechenov, V.; Pechenova, O.; Cavalcanti, T. Perez; Spataro, S.; Spruck, B.] Univ Giessen, Inst Phys 2, D-35392 Giessen, Germany, Email: laura.fabbietti@ph.tum.de
Corporate Author Thesis
Publisher Amer Physical Soc Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 0556-2813 ISBN Medium
Area Expedition Conference
Notes ISI:000283648400009 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ elepoucu @ Serial 334
Permanent link to this record
 

 
Author HADES Collaboration (Agakishiev, G. et al); Diaz, J.; Gil, A.
Title pp and pi pi intensity interferometry in collisions of Ar+KCl at 1.76A GeV Type Journal Article
Year 2011 Publication European Physical Journal A Abbreviated Journal Eur. Phys. J. A
Volume 47 Issue 5 Pages 63 - 8pp
Keywords (up)
Abstract Results on pp, pi(+) pi(+), and pi-pi-intensity interferometry are reported for collisions of Ar+KCl at 1.76A GeV beam energy, studied with the High Acceptance Di-Electron Spectrometer (HADES) at SIS18/GSI. The experimental correlation functions as a function of the relative momentum are compared to model calculations allowing the determination of the space-time extent of the corresponding emission sources. The pp source radii are found significantly larger than the pp emission radius. The present radii do well complement the beam-energy dependences of Gaussian source radii of the collision system of size A + A similar or equal to 40 + 40. The pp source radius at fixed beam energy is found to increase linearly with the cube root of the number of participants. From this trend, a lower limit of the pp correlation radius is deduced.
Address [Finocchiaro, P.] Ist Nazl Fis Nucl, Lab Nazl Sud, I-95125 Catania, Italy, Email: kotte@fzd.de
Corporate Author Thesis
Publisher Springer Place of Publication Editor
Language English Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1434-6001 ISBN Medium
Area Expedition Conference
Notes ISI:000291659900005 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 658
Permanent link to this record
 

 
Author NEXT Collaboration (Alvarez, V. et al); Agramunt, J.; Ball, M.; Bayarri, J.; Carcel, S.; Cervera-Villanueva, A.; Diaz, J.; Ferrario, P.; Gil, A.; Gomez-Cadenas, J.J.; Gonzalez, K.; Liubarsky, I.; Lorca, D.; Martin-Albo, J.; Monrabal, F.; Muñoz Vidal, J.; Nebot-Guinot, M.; Perez, J.; Rodriguez, J.; Serra, L.; Sorel, M.; Yahlali, N.
Title SiPMs coated with TPB: coating protocol and characterization for NEXT Type Journal Article
Year 2012 Publication Journal of Instrumentation Abbreviated Journal J. Instrum.
Volume 7 Issue Pages P02010
Keywords (up)
Abstract Silicon photomultipliers (SiPM) are the photon detectors chosen for the tracking read-out in NEXT, a neutrinoless beta beta decay experiment which uses a high pressure gaseous xenon time projection chamber (TPC). The reconstruction of event track and topology in this gaseous detector is a key handle for background rejection. Among the commercially available sensors that can be used for tracking, SiPMs offer important advantages, mainly high gain, ruggedness, cost-effectiveness and radio-purity. Their main drawback, however, is their non sensitivity in the emission spectrum of the xenon scintillation (peak at 175 nm). This is overcome by coating these sensors with the organic wavelength shifter tetraphenyl butadiene (TPB). In this paper we describe the protocol developed for coating the SiPMs with TPB and the measurements performed for characterizing the coatings as well as the performance of the coated sensors in the UV-VUV range.
Address
Corporate Author Thesis
Publisher Place of Publication Editor
Language Summary Language Original Title
Series Editor Series Title Abbreviated Series Title
Series Volume Series Issue Edition
ISSN 1748-0221 ISBN Medium
Area Expedition Conference
Notes WOS:000303940900076 Approved no
Is ISI yes International Collaboration yes
Call Number IFIC @ pastor @ Serial 1028
Permanent link to this record