|
Goigoux, T. et al, Algora, A., Guadilla, V., Montaner-Piza, A., Morales, A. I., Orrigo, S. E. A., et al. (2016). Two-Proton Radioactivity of Kr-67. Phys. Rev. Lett., 117(16), 162501–6pp.
Abstract: In an experiment with the BigRIPS separator at the RIKEN Nishina Center, we observed two-proton (2p) emission from Kr-67. At the same time, no evidence for 2p emission of Ge-59 and Se-63, two other potential candidates for this exotic radioactivity, could be observed. This observation is in line with Q value predictions which pointed to Kr-67 as being the best new candidate among the three for two-proton radioactivity. Kr-67 is only the fourth 2p ground-state emitter to be observed with a half-life of the order of a few milliseconds. The decay energy was determined to be 1690(17) keV, the 2p emission branching ratio is 37(14)%, and the half-life of Kr-67 is 7.4(30) ms.
|
|
|
n_TOF Collaboration(Barbagallo, M. et al), Domingo-Pardo, C., Tain, J. L., & Tarifeño-Saldivia, A. (2016). Be-7(n,alpha)He-4 Reaction and the Cosmological Lithium Problem: Measurement of the Cross Section in a Wide Energy Range at n_TOF at CERN. Phys. Rev. Lett., 117(15), 152701–7pp.
Abstract: The energy-dependent cross section of the (7)Bed(n,alpha)He-4 reaction, of interest for the so-called cosmological lithium problem in big bang nucleosynthesis, has been measured for the first time from 10 meV to 10 keV neutron energy. The challenges posed by the short half-life of Be-7 and by the low reaction cross section have been overcome at nTOF thanks to an unprecedented combination of the extremely high luminosity and good resolution of the neutron beam in the new experimental area (EAR2) of the nTOF facility at CERN, the availability of a sufficient amount of chemically pure Be-7, and a specifically designed experimental setup. Coincidences between the two alpha particles have been recorded in two Si-Be-7-Si arrays placed directly in the neutron beam. The present results are consistent, at thermal neutron energy, with the only previous measurement performed in the 1960s at a nuclear reactor. The energy dependence reported here clearly indicates the inadequacy of the cross section estimates currently used in BBN calculations. Although new measurements at higher neutron energy may still be needed, the n_TOF results hint at a minor role of this reaction in BBN, leaving the long-standing cosmological lithium problem unsolved.
|
|
|
LHCb Collaboration(Aaij, R. et al), Garcia Martin, L. M., Martinez-Vidal, F., Oyanguren, A., Remon Alepuz, C., Ruiz Valls, P., et al. (2016). Search for Structure in the B-s(0)pi(+/-) Invariant Mass Spectrum. Phys. Rev. Lett., 117(15), 152003–9pp.
Abstract: The B-s(0)pi(+/-) invariant mass distribution is investigated in order to search for possible exotic meson states. The analysis is based on a data sample recorded with the LHCb detector corresponding to 3 fb(-1) of pp collision data at root s 7 and 8 TeV. No significant excess is found, and upper limits are set on the production rate of the claimed X(5568) state within the LHCb acceptance. Upper limits are also set as a function of the mass and width of a possible exotic meson decaying to the B-s(0)pi(+/-) final state. The same limits also apply to a possible exotic meson decaying through the chain B-s(*0)pi(+/-), B-s(*0) -> B-s(0) gamma where the photon is excluded from the reconstructed decays.
|
|
|
Solevi, P., Muñoz, E., Solaz, C., Trovato, M., Dendooven, P., Gillam, J. E., et al. (2016). Performance of MACACO Compton telescope for ion-beam therapy monitoring: first test with proton beams. Phys. Med. Biol., 61(14), 5149–5165.
Abstract: In order to exploit the advantages of ion-beam therapy in a clinical setting, delivery verification techniques are necessary to detect deviations from the planned treatment. Efforts are currently oriented towards the development of devices for real-time range monitoring. Among the different detector concepts proposed, Compton cameras are employed to detect prompt gammas and represent a valid candidate for real-time range verification. We present the first on-beam test of MACACO, a Compton telescope (multi-layer Compton camera) based on lanthanum bromide crystals and silicon photo-multipliers. The Compton telescope was first characterized through measurements and Monte Carlo simulations. The detector linearity was measured employing Na-22 and Am-Be sources, obtaining about 10% deviation from linearity at 3.44 MeV. A spectral image reconstruction algorithm was tested on synthetic data. Point-like sources emitting gamma rays with energy between 2 and 7 MeV were reconstructed with 3-5 mm resolution. The two-layer Compton telescope was employed to measure radiation emitted from a beam of 150 MeV protons impinging on a cylindrical PMMA target. Bragg-peak shifts were achieved via adjustment of the PMMA target location and the resulting measurements used during image reconstruction. Reconstructed Bragg peak profiles proved sufficient to observe peak-location differences within 10 mm demonstrating the potential of the MACACO Compton Telescope as a monitoring device for ion-beam therapy.
|
|
|
Barenboim, G., & Park, W. I. (2016). Small changes to the inflaton potential can result in large changes in observables. Phys. Rev. D, 93(12), 123508–5pp.
Abstract: We show that a tiny correction to the inflaton potential can make critical changes in the inflationary observables for some types of inflation models.
|
|