|
Caballero-Folch, R. et al, Domingo-Pardo, C., Agramunt, J., Algora, A., Rubio, B., & Tain, J. L. (2016). First Measurement of Several beta-Delayed Neutron Emitting Isotopes Beyond N=126. Phys. Rev. Lett., 117(1), 012501–6pp.
Abstract: The beta-delayed neutron emission probabilities of neutron rich Hg and Tl nuclei have been measured together with beta-decay half-lives for 20 isotopes of Au, Hg, Tl, Pb, and Bi in the mass region N greater than or similar to 126. These are the heaviest species where neutron emission has been observed so far. These measurements provide key information to evaluate the performance of nuclear microscopic and phenomenological models in reproducing the high-energy part of the beta-decay strength distribution. This provides important constraints on global theoretical models currently used in r-process nucleosynthesis.
|
|
|
n_TOF Collaboration(Mastromarco, M. et al), Domingo-Pardo, C., & Tain, J. L. (2019). Cross section measurements of Gd-155,Gd-157(n,) induced by thermal and epithermal neutrons. Eur. Phys. J. A, 55(1), 9–20pp.
Abstract: Neutron capture cross section measurements on Gd-155 and Gd-157 were performed using the time-of-flight technique at the nTOF facility at CERN on isotopically enriched samples. The measurements were carried out in the nTOF experimental area EAR1, at 185 m from the neutron source, with an array of 4 C6D6 liquid scintillation detectors. At a neutron kinetic energy of 0.0253 eV, capture cross sections of 62.2(2.2) and 239.8(8.4) kilobarn have been derived for Gd-155 and Gd-157, respectively, with up to 6% deviation relative to values presently reported in nuclear data libraries, but consistent with those values within 1.6 standard deviations. A resonance shape analysis has been performed in the resolved resonance region up to 181 eV and 307 eV, respectively for Gd-155 and Gd-157, where on average, resonance parameters have been found in good agreement with evaluations. Above these energies and up to 1 keV, the observed resonance-like structure of the cross section has been analysed and characterised. From a statistical analysis of the observed neutron resonances we deduced: neutron strength function of 2.01(28)x10-4 and 2.17(41)x10-4; average total radiative width of 106.8(14) meV and 101.1(20) meV and s-wave resonance spacing 1.6(2) eV and 4.8(5) eV for n + Gd-155 and n + Gd-157 systems, respectively.
|
|
|
Phong, V. H. et al, Agramunt, J., Algora, A., Domingo-Pardo, C., Morales, A. I., Tain, J. L., et al. (2019). Observation of a μs isomer in In-134(49)85: Proton-neutron coupling “southeast” of Sn-132(50)82. Phys. Rev. C, 100(1), 011302–6pp.
Abstract: We report on the observation of a microsecond isomeric state in the single-proton-hole, three-neutron-particle nucleus In-134. The nuclei of interest were produced by in-flight fission of a U-238 beam at the Radioactive Isotope Beam Factory at RIKEN. The isomer depopulates through a gamma ray of energy 56.7(1) keV and with a half-life of T-1/2 = 3.5(4) μs. Based on the comparison with shell-model calculations, we interpret the isomer as the I-pi = 5(-) member of the pi 0g(9/2)(-1) circle times nu 1f(7/2)(3) multiplet, decaying to the I-pi = 7(-) ground state with a reduced-transition probability of B(E2; 5(-) -> 7(-)) = 0.53(6) W.u. Observation of this isomer, and lack of evidence in the current work for a I-pi = 5(-) isomer decay in In-132, provides a benchmark of the proton-neutron interaction in the region of the nuclear chart “southeast” of Sn-132, where experimental information on excited states is sparse.
|
|
|
n_TOF Collaboration(Stamatopoulos, A. et al), Domingo-Pardo, C., Tain, J. L., & Tarifeño-Saldivia, A. (2020). Investigation of the Pu-240(n, f) reaction at the n_TOF/EAR2 facility in the 9 meV-6 MeV range. Phys. Rev. C, 102(1), 014616–23pp.
Abstract: Background: Nuclear waste management is considered amongst the major challenges in the field of nuclear energy. A possible means of addressing this issue is waste transmutation in advanced nuclear systems, whose operation requires a fast neutron spectrum. In this regard, the accurate knowledge of neutron-induced reaction cross sections of several (minor) actinide isotopes is essential for design optimization and improvement of safety margins of such systems. One such case is Pu-240, due to its accumulation in spent nuclear fuel of thermal reactors and its usage in fast reactor fuel. The measurement of the Pu-240(n, f) cross section was previously attempted at the CERN nTOF facility EAR1 measuring station using the time-of-flight technique. Due to the low amount of available material and the given flux at EAR1, the measurement had to last several months to achieve a sufficient statistical accuracy. This long duration led to detector deterioration due to the prolonged exposure to the high alpha activity of the fission foils, therefore the measurement could not be successfully completed. Purpose: It is aimed to determine whether it is feasible to study neutron-induced fission at nTOF/EAR2 and provide data on the Pu-240(n, f) reaction in energy regions requested for applications. Methods: The study of the Pu-240(n, f) reaction was made at a new experimental area (EAR2) with a shorter flight path which delivered on average 30 times higher flux at fast neutron energies. This enabled the measurement to be performed much faster, thus limiting the exposure of the detectors to the intrinsic activity of the fission foils. The experimental setup was based on microbulk Micromegas detectors and the time-of-flight data were analyzed with an optimized pulse-shape analysis algorithm. Special attention was dedicated to the estimation of the non-negligible counting loss corrections with the development of a new methodology, and other corrections were estimated via Monte Carlo simulations of the experimental setup. Results: This new measurement of the Pu-240(n, f) cross section yielded data from 9 meV up to 6 MeV incident neutron energy and fission resonance kernels were extracted up to 10 keV. Conclusions: Neutron-induced fission of high activity samples can be successfully studied at the n_TOF/EAR2 facility at CERN covering a wide range of neutron energies, from thermal to a few MeV.
|
|
|
Lerendegui-Marco, J., Balibrea-Correa, J., Babiano-Suarez, V., Ladarescu, I., & Domingo-Pardo, C. (2022). Towards machine learning aided real-time range imaging in proton therapy. Sci Rep, 12(1), 2735–17pp.
Abstract: Compton imaging represents a promising technique for range verification in proton therapy treatments. In this work, we report on the advantageous aspects of the i-TED detector for proton-range monitoring, based on the results of the first Monte Carlo study of its applicability to this field. i-TED is an array of Compton cameras, that have been specifically designed for neutron-capture nuclear physics experiments, which are characterized by gamma-ray energies spanning up to 5-6 MeV, rather low gamma-ray emission yields and very intense neutron induced gamma-ray backgrounds. Our developments to cope with these three aspects are concomitant with those required in the field of hadron therapy, especially in terms of high efficiency for real-time monitoring, low sensitivity to neutron backgrounds and reliable performance at the high gamma-ray energies. We find that signal-to-background ratios can be appreciably improved with i-TED thanks to its light-weight design and the low neutron-capture cross sections of its LaCl3 crystals, when compared to other similar systems based on LYSO, CdZnTe or LaBr3. Its high time-resolution (CRT similar to 500 ps) represents an additional advantage for background suppression when operated in pulsed HT mode. Each i-TED Compton module features two detection planes of very large LaCl3 monolithic crystals, thereby achieving a high efficiency in coincidence of 0.2% for a point-like 1 MeV gamma-ray source at 5 cm distance. This leads to sufficient statistics for reliable image reconstruction with an array of four i-TED detectors assuming clinical intensities of 10(8) protons per treatment point. The use of a two-plane design instead of three-planes has been preferred owing to the higher attainable efficiency for double time-coincidences than for threefold events. The loss of full-energy events for high energy gamma-rays is compensated by means of machine-learning based algorithms, which allow one to enhance the signal-to-total ratio up to a factor of 2.
|
|