|
LHCb Collaboration(Aaij, R. et al), Martinez-Vidal, F., Oyanguren, A., Ruiz Valls, P., & Sanchez Mayordomo, C. (2014). Measurement of the Xi(-)(b) and Omega(-)(b) baryon lifetimes. Phys. Lett. B, 736, 154–162.
Abstract: Using a data sample of pp collisions corresponding to an integrated luminosity of 3 fb(-1), the Xi(-)(b) and Omega(-)(b) baryons are reconstructed in the Xi(-)(b) -> J/psi Xi(-) and Omega(-)(b) -> J/psi Omega(-) decay modes and their lifetimes measured to be tau(Xi(-)(b)) = 1.55(-0.09)(+0.10) (stat) +/- 0.03 (syst) ps, tau(Omega(-)(b)) = 1.54(-0.21)(+0.26) (stat) +/- 0.05 (syst) ps. These are the most precise determinations to date. Both measurements are in good agreement with previous experimental results and with theoretical predictions.
|
|
|
LHCb Collaboration(Aaij, R. et al), Martinez-Vidal, F., Oyanguren, A., Ruiz Valls, P., & Sanchez Mayordomo, C. (2014). Measurement of the CP-violating phase phi(s) in (B)over-bar(s)(0) -> J / psi pi(+)pi(-) decays. Phys. Lett. B, 736, 186–195.
Abstract: The mixing-induced CP-violating phase phi(s) in B-s(0) and (B) over bar (0)(s) decays is measured using the J / psi pi(+)pi(-) final state in data, taken from 3 fb(-1) of integrated luminosity, collected with the LHCb detector in 7 and 8 TeV centre-of-mass pp collisions at the LHC. A time-dependent flavour-tagged amplitude analysis, allowing for direct CP violation, yields a value for the phase phi(s) = 70 +/- 68 +/- 8 mrad. This result is consistent with the Standard Model expectation and previous measurements.
|
|
|
LHCb Collaboration(Aaij, R. et al), Martinez-Vidal, F., Oyanguren, A., Ruiz Valls, P., & Sanchez Mayordomo, C. (2014). Effective lifetime measurements in the B-s(0) -> K+K-, B-0 -> K+pi(-) and B-s(0) -> pi K-+(-) decays. Phys. Lett. B, 736, 446–454.
Abstract: Measurements of the effective lifetimes in the B-s(0) -> K+K-, B-0 -> K+pi(-) and B-s(0) -> pi K-+(-) decays are presented using 1.0 fb(-1)of pp collision data collected at a centre-of-mass energy of 7 TeV by the LHCb experiment. The analysis uses a data-driven approach to correct for the decay time acceptance. The measured effective lifetimes are tau(Bs0 -> K+K-) = 1.407 +/- 0.016 (stat) +/- 0.007 (syst) ps, tau(Bs0 -> K+pi-) = 1.524 +/- 0.011 (stat) +/- 0.004 (syst) ps, tau(Bs0 ->pi+K-) = 1.60 +/- 0.06 (stat) +/- 0.01 (syst) ps. This is the most precise determination to date of the effective lifetime in the B-s(0) -> K+K- decay and provides constraints on contributions from physics beyond the Standard Model to the B-s(0) mixing phase and the width difference Delta Gamma(s).
|
|
|
LHCb Collaboration(Aaij, R. et al), Martinez-Vidal, F., Oyanguren, A., Ruiz Valls, P., & Sanchez Mayordomo, C. (2014). Measurement of CP violation and constraints on the CKM angle gamma in B-+/- -> DK +/- with D -> K-s(0)pi(+)pi(-) decays. Nucl. Phys. B, 888, 169–193.
Abstract: A model-dependent amplitude analysis of B-+/- -> DK +/- with D -> K-s(0)pi(+)pi(-) decays is performed using proton proton collision data, corresponding to an integrated luminosity of 1 fb(-1), recorded by LHCb at a centre-of-mass energy of 7 TeV in 2011. Values of the CP violation observables x +/- and y +/-, which are sensitive to the CKM angle gamma, are measured to be x- = +0.027 +/- 0.0441(-0.008)(+0.010) +/- 0.001, y- = +0.013 +/- 0.0481(-0.007)(+0.009) +/- 0.003, x+ = -0.084 +/- 0.045 +/- 0.009 +/- 0.005, y+ = -0.032 +/- 0.048(-0.009)(+0.010) +/- 0.008, where the first uncertainty is statistical, the second systematic and the third arises from the uncertainty of the D -> K-S(0)pi(+)pi(-) amplitude model. The value of gamma is determined to be (84(-42)(+49))degrees including all sources of uncertainty. Neutral D meson mixing is found to have negligible effect.
|
|
|
LHCb Collaboration(Aaij, R. et al), Martinez-Vidal, F., Oyanguren, A., Ruiz Valls, P., & Sanchez Mayordomo, C. (2014). Precision luminosity measurements at LHCb. J. Instrum., 9, P12005–91pp.
Abstract: Measuring cross-sections at the LHC requires the luminosity to be determined accurately at each centre-of-mass energy root s. In this paper results are reported from the luminosity calibrations carried out at the LHC interaction point 8 with the LHCb detector for root s = 2.76, 7 and 8TeV (proton-proton collisions) and for root s(NN) = 5TeV (proton-lead collisions). Both the “van der Meer scan” and “beam-gas imaging” luminosity calibration methods were employed. It is observed that the beam density profile cannot always be described by a function that is factorizable in the two transverse coordinates. The introduction of a two-dimensional description of the beams improves significantly the consistency of the results. For proton-proton interactions at root s = 8TeV a relative precision of the luminosity calibration of 1.47% is obtained using van der Meer scans and 1.43% using beam-gas imaging, resulting in a combined precision of 1.12%. Applying the calibration to the full data set determines the luminosity with a precision of 1.16%. This represents the most precise luminosity measurement achieved so far at a bunched-beam hadron collider.
|
|