Albaladejo, M. (2022). T-cc(+) coupled channel analysis and predictions. Phys. Lett. B, 829, 137052–13pp.
Abstract: A coupled channel analysis of the D*D-+(0) and D*D-0(+) system is performed to study the doubly charmed T-cc(+) state recently discovered by the LHCb collaboration. We use a simple model for the scattering amplitude and production mechanism that allows us to describe well the experimental spectrum, and obtain the T-cc(+) pole in the coupled channel T-matrix. We find that this bound state has a large molecular component. The isospin (I = 0 or I = 1) of the state cannot be inferred from the (DD0)-D-0 pi(+) spectrum alone, although there is some experimental evidence that points to the I = 0 interpretation. Therefore, we use the same formalism to predict other DD pi spectra. In the case the T-cc(+) has I = 1, we also predict the location of the other two members (T-cc(+) and T-cc(0)) of the triplet. Finally, using Heavy-Quark Spin Symmetry, we predict the location of possible heavier D*D* (I = 0 or I= 1) partners.
|
Hernandez, E., Nieves, J., Sanchez, F., & Sobczyk, J. E. (2022). Tau longitudinal and transverse polarizations from visible kinematics in (anti-)neutrino nucleus scattering. Phys. Lett. B, 829, 137046–9pp.
Abstract: Since the upsilon(tau) ((upsilon) over bar (tau))A(Z) -> tau(-/+) X reaction is notoriously difficult to be directly measured, the information on the dynamics of this nuclear process should be extracted from the analysis of the energy and angular distributions of the tau decay visible products. These distributions depend, in addition to d(2)sigma / (dE(tau)d cos theta(tau)), on the components of the tau-polarization vector. We give, for the first time, the general expression for the outgoing hadron (pion or rho meson) energy and angular differential cross section for the sequential upsilon(tau) A(Z) -> tau(-) (pi(-)upsilon(tau,) rho(-)upsilon(tau))X and (upsilon) over bar (tau)A(Z) -> tau(+) (pi(+)(upsilon) over bar (tau), rho(+)(upsilon) over bar (tau)) X reactions. Though all possible nuclear reaction mechanisms contribute to the distribution, it may be possible to isolate/enhance one of them by implementing appropriate selection criteria. For the case of the quasi-elastic reaction off oxygen and neutrino energies below 6 GeV, we show that the pion distributions are quite sensitive to the details of the tau-polarization components. We find significant differences between the full calculation, where the longitudinal and transverse components of the tau polarization vector vary with the energy and the scattering angle of the produced tau, and the simplified scheme in which the polarizations are set to one and zero, being the latter their respective asymptotic values reached in the high energy regime. In addition to its potential impact on neutrino oscillation analyses, this result can be used to further test different nuclear models, since these observables provide complementary information to that obtained by means of the inclusive nuclear weak charged-current differential cross section. We also study the effects on the cross section of the W-4 and W-5 nuclear structure functions, which contributions are proportional to the charged lepton mass, and therefore difficult to constrain in muon and electron neutrino experiments.
|
Olmo, G. J., Rubiera-Garcia, D., & Saez-Chillon Gomez, D. (2022). New light rings from multiple critical curves as observational signatures of black hole mimickers. Phys. Lett. B, 829, 137045–5pp.
Abstract: We argue that the appearance of additional light rings in a shadow observation – beyond the infinite sequence of exponentially demagnified self-similar rings foreseen in the Kerr solution – would make a compelling case for the existence of black hole mimickers having multiple critical curves. We support this claim by discussing three different scenarios of spherically symmetric wormhole geometries having two such critical curves, and explicitly work out the optical appearance of one such object when surrounded by an optically and geometrically thin accretion disk.
|
Stoppa, F., Vreeswijk, P., Bloemen, S., Bhattacharyya, S., Caron, S., Johannesson, G., et al. (2022). AutoSourceID-Light Fast optical source localization via U-Net and Laplacian of Gaussian. Astron. Astrophys., 662, A109–8pp.
Abstract: Aims. With the ever-increasing survey speed of optical wide-field telescopes and the importance of discovering transients when they are still young, rapid and reliable source localization is paramount. We present AutoSourceID-Light (ASID-L), an innovative framework that uses computer vision techniques that can naturally deal with large amounts of data and rapidly localize sources in optical images. Methods. We show that the ASID-L algorithm based on U-shaped networks and enhanced with a Laplacian of Gaussian filter provides outstanding performance in the localization of sources. A U-Net network discerns the sources in the images from many different artifacts and passes the result to a Laplacian of Gaussian filter that then estimates the exact location. Results. Using ASID-L on the optical images of the MeerLICHT telescope demonstrates the great speed and localization power of the method. We compare the results with SExtractor and show that our method outperforms this more widely used method. ASID-L rapidly detects more sources not only in low- and mid-density fields, but particularly in areas with more than 150 sources per square arcminute. The training set and code used in this paper are publicly available.
Keywords: astronomical databases; miscellaneous; methods; data analysis; stars; imaging; techniques; image processing
|
Mandal, S., Miranda, O. G., Sanchez Garcia, G., Valle, J. W. F., & Xu, X. J. (2022). High-energy colliders as a probe of neutrino properties. Phys. Lett. B, 829, 137110–5pp.
Abstract: The mediators of neutrino mass generation can provide a probe of neutrino properties at the next round of high-energy hadron (FCC-hh) and lepton colliders (FCC-ee/ILC/CEPC/CLIC). We show how the decays of the Higgs triplet scalars mediating the simplest seesaw mechanism can shed light on the neutrino mass scale and mass-ordering, as well as the atmospheric octant. Four-lepton signatures at the high-energy frontier may provide the discovery-site for charged lepton flavor non-conservation in nature, rather than low-energy intensity frontier experiments.
|
SCiMMA and SNEWS Collaborations(Baxter, A. L. et al), & Colomer, M. (2022). Collaborative experience between scientific software projects using Agile Scrum development. Softw.-Pract. Exp., 52, 2077–2096.
Abstract: Developing sustainable software for the scientific community requires expertise in software engineering and domain science. This can be challenging due to the unique needs of scientific software, the insufficient resources for software engineering practices in the scientific community, and the complexity of developing for evolving scientific contexts. While open-source software can partially address these concerns, it can introduce complicating dependencies and delay development. These issues can be reduced if scientists and software developers collaborate. We present a case study wherein scientists from the SuperNova Early Warning System collaborated with software developers from the Scalable Cyberinfrastructure for Multi-Messenger Astrophysics project. The collaboration addressed the difficulties of open-source software development, but presented additional risks to each team. For the scientists, there was a concern of relying on external systems and lacking control in the development process. For the developers, there was a risk in supporting a user-group while maintaining core development. These issues were mitigated by creating a second Agile Scrum framework in parallel with the developers' ongoing Agile Scrum process. This Agile collaboration promoted communication, ensured that the scientists had an active role in development, and allowed the developers to evaluate and implement the scientists' software requirements. The collaboration provided benefits for each group: the scientists actuated their development by using an existing platform, and the developers utilized the scientists' use-case to improve their systems. This case study suggests that scientists and software developers can avoid scientific computing issues by collaborating and that Agile Scrum methods can address emergent concerns.
|
Addazi, A. et al, Martinez-Mirave, P., Mitsou, V. A., Palomares-Ruiz, S., Tortola, M., & Zornoza, J. D. (2022). Quantum gravity phenomenology at the dawn of the multi-messenger era-A review. Prog. Part. Nucl. Phys., 125, 103948–119pp.
Abstract: The exploration of the universe has recently entered a new era thanks to the multi-messenger paradigm, characterized by a continuous increase in the quantity and quality of experimental data that is obtained by the detection of the various cosmic messengers (photons, neutrinos, cosmic rays and gravitational waves) from numerous origins. They give us information about their sources in the universe and the properties of the intergalactic medium. Moreover, multi-messenger astronomy opens up the possibility to search for phenomenological signatures of quantum gravity. On the one hand, the most energetic events allow us to test our physical theories at energy regimes which are not directly accessible in accelerators; on the other hand, tiny effects in the propagation of very high energy particles could be amplified by cosmological distances. After decades of merely theoretical investigations, the possibility of obtaining phenomenological indications of Planck-scale effects is a revolutionary step in the quest for a quantum theory of gravity, but it requires cooperation between different communities of physicists (both theoretical and experimental). This review, prepared within the COST Action CA18108 “Quantum gravity phenomenology in the multi-messenger approach”, is aimed at promoting this cooperation by giving a state-of-the art account of the interdisciplinary expertise that is needed in the effective search of quantum gravity footprints in the production, propagation and detection of cosmic messengers.
|
Vitez-Sveiczer, A. et al, Algora, A., Morales, A. I., Rubio, B., Agramunt, J., Guadilla, V., et al. (2022). The beta-decay of Kr-70 into Br-70: Restoration of the pseudo-SU(4) symmetry. Phys. Lett. B, 830, 137123–8pp.
Abstract: The beta-decay of the even-even nucleus Kr-70 with Z=N+2, has been investigated at the Radioactive Ion Beam Factory (RIBF) of the RIKEN Nishina Center using the BigRIPS fragment separator, the ZeroDegree Spectrometer, the WAS3ABI implantation station and the EURICA HPGe cluster array. Fifteen gamma-rays associated with the beta-decay of( 70)Kr into Br-70 have been identified for the first time, defining ten populated states below E-exc=3300 keV. The half-life of Kr-70 was derived with increased precision and found to be t(1/2)=45.19 +/- 0.14 ms. The beta-delayed proton emission probability has also been determined as epsilon(p)=0.545(23)%. An increase in the beta-strength to the yrast 1(+) state in comparison with the heaviest Z=N+2 system studied so far (Ge-62 decay) is observed that may indicate increased np correlations in the T=0 channel. The beta-decay strength deduced from the results is interpreted in terms of the proton-neutron quasiparticle random-phase approximation (pnQRPA) and also with a schematic model that includes isoscalar and isovector pairing in addition to quadrupole deformation. The application of this last model indicates an approximate realization of pseudo-SU(4) symmetry in this system.
|
Hueso-Gonzalez, F., Casaña Copado, J. V., Fernandez Prieto, A., Gallas Torreira, A., Lemos Cid, E., Ros Garcia, A., et al. (2022). A dead-time-free data acquisition system for prompt gamma-ray measurements during proton therapy treatments. Nucl. Instrum. Methods Phys. Res. A, 1033, 166701–9pp.
Abstract: In cancer patients undergoing proton therapy, a very intense secondary radiation is produced during the treatment, which lasts around one minute. About one billion prompt gamma-rays are emitted per second, and their detection with fast scintillation detectors is useful for monitoring a correct beam delivery. To cope with the expected count rate and pile-up, as well as the scarce statistics due to the short treatment duration, we developed an eidetic data acquisition system capable of continuously digitizing the detector signal with a high sampling rate and without any dead time. By streaming the fully unprocessed waveforms to the computer, complex pile-up decomposition algorithms can be applied and optimized offline. We describe the data acquisition architecture and the multiple experimental tests designed to verify the sustained data throughput speed and the absence of dead time. While the system is tailored for the proton therapy environment, the methodology can be deployed in any other field requiring the recording of raw waveforms at high sampling rates with zero dead time.
Keywords: Data acquisition; Dead time; Pile-up; Digital signal processing
|
Assam, I., Vijande, J., Ballester, F., Perez-Calatayud, J., Poppe, B., & Siebert, F. A. (2022). Evaluation of dosimetric effects of metallic artifact reduction and tissue assignment on Monte Carlo dose calculations for I-125 prostate implants. Med. Phys., 49, 6195–6208.
Abstract: Purpose Monte Carlo (MC) simulation studies, aimed at evaluating the magnitude of tissue heterogeneity in I-125 prostate permanent seed implant brachytherapy (BT), customarily use clinical post-implant CT images to generate a virtual representation of a realistic patient model (virtual patient model). Metallic artifact reduction (MAR) techniques and tissue assignment schemes (TAS) are implemented on the post-implant CT images to mollify metallic artifacts due to BT seeds and to assign tissue types to the voxels corresponding to the bright seed spots and streaking artifacts, respectively. The objective of this study is to assess the combined influence of MAR and TAS on MC absorbed dose calculations in post-implant CT-based phantoms. The virtual patient models used for I-125 prostate implant MC absorbed dose calculations in this study are derived from the CT images of an external radiotherapy prostate patient without BT seeds and prostatic calcifications, thus averting the need to implement MAR and TAS. Methods The geometry of the IsoSeed I25.S17plus source is validated by comparing the MC calculated results of the TG-43 parameters for the line source approximation with the TG-43U1S2 consensus data. Four MC absorbed dose calculations are performed in two virtual patient models using the egs_brachy MC code: (1) TG-43-based D-w,w-TG(43), (2) D-w,D-w-MBDC that accounts for interseed scattering and attenuation (ISA), (3) D-m,D-m that examines ISA and tissue heterogeneity by scoring absorbed dose in tissue, and (4) D-w,D-m that unlike D-m,D-m scores absorbed dose in water. The MC absorbed doses (1) and (2) are simulated in a TG-43 patient phantom derived by assigning the densities of every voxel to 1.00 g cm(-3) (water), whereas MC absorbed doses (3) and (4) are scored in the TG-186 patient phantom generated by mapping the mass density of each voxel to tissue according to a CT calibration curve. The MC absorbed doses calculated in this study are compared with VariSeed v8.0 calculated absorbed doses. To evaluate the dosimetric effect of MAR and TAS, the MC absorbed doses of this work (independent of MAR and TAS) are compared to the MC absorbed doses of different I-125 source models from previous studies that were calculated with different MC codes using post-implant CT-based phantoms generated by implementing MAR and TAS on post-implant CT images. Results The very good agreement of TG-43 parameters of this study and the published consensus data within 3% validates the geometry of the IsoSeed I25.S17plus source. For the clinical studies, the TG-43-based calculations show a D-90 overestimation of more than 4% compared to the more realistic MC methods due to ISA and tissue composition. The results of this work generally show few discrepancies with the post-implant CT-based dosimetry studies with respect to the D-90 absorbed dose metric parameter. These discrepancies are mainly Type B uncertainties due to the different I-125 source models and MC codes. Conclusions The implementation of MAR and TAS on post-implant CT images have no dosimetric effect on the I-125 prostate MC absorbed dose calculation in post-implant CT-based phantoms.
|