ANTARES Collaboration(Aguilar, J. A. et al), Bigongiari, C., Emanuele, U., Gomez-Gonzalez, J. P., Hernandez-Rey, J. J., Mangano, S., et al. (2010). Measurement of the atmospheric muon flux with a 4 GeV threshold in the ANTARES neutrino telescope. Astropart Phys., 33(2), 86–90.
Abstract: A new method for the measurement of the muon flux in the deep-sea ANTARES neutrino telescope and its dependence on the depth is presented. The method is based oil the observation of coincidence signals in adjacent storeys of the detector. This yields an energy threshold of about 4 GeV. The main sources of optical background are the decay of K-40 and the bioluminescence in the sea water. The K-40 background is used to calibrate the efficiency of the photo-multiplier tubes.
|
|
|
Pierre Auger Collaboration(Abraham, J. et al), & Pastor, S. (2010). A study of the effect of molecular and aerosol conditions in the atmosphere on air fluorescence measurements at the Pierre Auger Observatory. Astropart Phys., 33(2), 108–129.
Abstract: The air fluorescence detector of the Pierre Auger Observatory is designed to perforin calorimetric measurements of extensive air showers created by Cosmic rays of above 10(18) eV. To correct these measurements for the effects introduced by atmospheric fluctuations, the Observatory contains a group Of monitoring instruments to record atmospheric conditions across the detector site, ail area exceeding 3000 km(2). The atmospheric data are used extensively in the reconstruction of air showers, and are particularly important for the correct determination of shower energies and the depths of shower maxima. This paper contains a summary of the molecular and aerosol conditions measured at the Pierre Auger Observatory since the start of regular operations in 2004, and includes a discussion of the impact of these measurements oil air shower reconstructions. Between 10(18) and 10(20) eV, the systematic Uncertainties due to all atmospheric effects increase from 4% to 8% in measurements of shower energy, and 4 g cm(-2) to 8 g cm(-2) in measurements of the shower maximum.
|
|
|
Rivard, M. J., Granero, D., Perez-Calatayud, J., & Ballester, F. (2010). Influence of photon energy spectra from brachytherapy sources on Monte Carlo simulations of kerma and dose rates in water and air. Med. Phys., 37(2), 869–876.
Abstract: Methods: For Ir-192, I-125, and Pd-103, the authors considered from two to five published spectra. Spherical sources approximating common brachytherapy sources were assessed. Kerma and dose results from GEANT4, MCNP5, and PENELOPE-2008 were compared for water and air. The dosimetric influence of Ir-192, I-125, and Pd-103 spectral choice was determined. Results: For the spectra considered, there were no statistically significant differences between kerma or dose results based on Monte Carlo code choice when using the same spectrum. Water-kerma differences of about 2%, 2%, and 0.7% were observed due to spectrum choice for Ir-192, I-125, and Pd-103, respectively (independent of radial distance), when accounting for photon yield per Bq. Similar differences were observed for air-kerma rate. However, their ratio (as used in the dose-rate constant) did not significantly change when the various photon spectra were selected because the differences compensated each other when dividing dose rate by air-kerma strength. Conclusions: Given the standardization of radionuclide data available from the National Nuclear Data Center (NNDC) and the rigorous infrastructure for performing and maintaining the data set evaluations, NNDC spectra are suggested for brachytherapy simulations in medical physics applications.
|
|
|
BABAR Collaboration(Aubert, B. et al), Azzolini, V., Lopez-March, N., Martinez-Vidal, F., Milanes, D. A., & Oyanguren, A. (2010). Searches for Lepton Flavor Violation in the Decays tau(+/-) -> e(+/-)gamma and tau(+/-) -> mu(+/-)gamma. Phys. Rev. Lett., 104(2), 021802–7pp.
Abstract: Searches for lepton-flavor-violating decays of a tau lepton to a lighter mass lepton and a photon have been performed with the entire data set of (963 +/- 7) x 10(6) tau decays collected by the BABAR detector near the Y(4S), Y(3S) and Y(2S) resonances. The searches yield no evidence of signals and we set upper limits on the branching fractions of B(tau(+/-) -> e(+/-)gamma) < 3.3 X 10(-8) and B(tau(+/-) -> mu(+/-)gamma) < 4.4 X 10(-8) at 90% confidence level.
|
|
|
Pierre Auger Collaboration(Abraham, J. et al), & Pastor, S. (2010). The fluorescence detector of the Pierre Auger Observatory. Nucl. Instrum. Methods Phys. Res. A, 620(2-3), 227–251.
Abstract: The Pierre Auger Observatory is a hybrid detector for ultra-high energy cosmic rays. It combines a surface array to measure secondary particles at ground level together with a fluorescence detector to measure the development of air showers in the atmosphere above the array. The fluorescence detector comprises 24 large telescopes specialized for measuring the nitrogen fluorescence caused by charged particles of cosmic ray air showers. In this paper we describe the components of the fluorescence detector including its optical system, the design of the camera, the electronics, and the systems for relative and absolute calibration. We also discuss the operation and the monitoring of the detector. Finally, we evaluate the detector performance and precision of shower reconstructions.
|
|