|
Fallot, M., Cormon, S., Estienne, M., Algora, A., Bui, V. M., Cucoanes, A., et al. (2012). New Antineutrino Energy Spectra Predictions from the Summation of Beta Decay Branches of the Fission Products. Phys. Rev. Lett., 109(20), 202504–5pp.
Abstract: In this Letter, we study the impact of the inclusion of the recently measured beta decay properties of the Tc-102;104;105;106;107, Mo-105, and Nb-101 nuclei in an updated calculation of the antineutrino energy spectra of the four fissible isotopes U-235,U-238 and Pu-239,Pu-241. These actinides are the main contributors to the fission processes in pressurized water reactors. The beta feeding probabilities of the above-mentioned Tc, Mo, and Nb isotopes have been found to play a major role in the gamma component of the decay heat of Pu-239, solving a large part of the gamma discrepancy in the 4-3000 s range. They have been measured by using the total absorption technique, insensitive to the pandemonium effect. The calculations are performed by using the information available nowadays in the nuclear databases, summing all the contributions of the beta decay branches of the fission products. Our results provide a new prediction of the antineutrino energy spectra of U-235, Pu-239,Pu-241, and, in particular, U-238 for which no measurement has been published yet. We conclude that new total absorption technique measurements are mandatory to improve the reliability of the predicted spectra.
|
|
|
BABAR Collaboration(Lees, J. P. et al), Martinez-Vidal, F., & Oyanguren, A. (2012). Precision Measurement of the B -> Xs gamma Photon Energy Spectrum, Branching Fraction, and Direct CP Asymmetry ACP(B -> Xs+d gamma). Phys. Rev. Lett., 109(19), 191801–8pp.
Abstract: The photon spectrum in the inclusive electromagnetic radiative decays of the B meson, B --> X-s gamma plus B --> X-d gamma, is studied using a data sample of (382.8 +/- 4.2) x 10(6)Y(4S) --> B (B) over bar decays collected by the BABAR experiment at SLAC. The spectrum is used to extract the branching fraction B(B --> X-s gamma) = (3.21 +/- 0.33) x 10(-4) for E-gamma > 1.8 GeV and the direct CP asymmetry A(CP)(B --> Xs+d gamma) = 0.057 +/- 0.063. The effects of detector resolution and Doppler smearing are unfolded to measure the photon energy spectrum in the B meson rest frame.
|
|
|
ATLAS Collaboration(Aad, G. et al), Cabrera Urban, S., Castillo Gimenez, V., Costa, M. J., Ferrer, A., Fiorini, L., et al. (2012). Search for Magnetic Monopoles in root s=7 TeV pp Collisions with the ATLAS Detector. Phys. Rev. Lett., 109(26), 261803–18pp.
Abstract: This Letter presents a search for magnetic monopoles with the ATLAS detector at the CERN Large Hadron Collider using an integrated luminosity of 2.0 fb(-1) of pp collisions recorded at a center-of-mass energy root s = 7 TeV. No event is found in the signal region, leading to an upper limit on the production cross section at 95% confidence level of 1.6/epsilon fb for Dirac magnetic monopoles with the minimum unit magnetic charge and with mass between 200 GeV and 1500 GeV, where epsilon is the monopole reconstruction efficiency. The efficiency epsilon is high and uniform in the fiducial region given by pseudorapidity vertical bar eta vertical bar < 1: 37 and transverse kinetic energy 600-700<E-kin sin theta< 1400 GeV. The minimum value of 700 GeV is for monopoles of mass 200 GeV, whereas the minimum value of 600 GeV is applicable for higher mass monopoles. Therefore, the upper limit on the production cross section at 95% confidence level is 2 fb in this fiducial region. Assuming the kinematic distributions from Drell-Yan pair production of spin-1= 2 Dirac magnetic monopoles, the efficiency is in the range 1%-10%, leading to an upper limit on the cross section at 95% confidence level that varies from 145 fb to 16 fb for monopoles with mass between 200 GeV and 1200 GeV. This limit is weaker than the fiducial limit because most of these monopoles lie outside the fiducial region.
|
|
|
Cabello, J., & Rafecas, M. (2012). Comparison of basis functions for 3D PET reconstruction using a Monte Carlo system matrix. Phys. Med. Biol., 57(7), 1759–1777.
Abstract: In emission tomography, iterative statistical methods are accepted as the reconstruction algorithms that achieve the best image quality. The accuracy of these methods relies partly on the quality of the system response matrix (SRM) that characterizes the scanner. The more physical phenomena included in the SRM, the higher the SRM quality, and therefore higher image quality is obtained from the reconstruction process. High-resolution small animal scanners contain as many as 10(3)-10(4) small crystal pairs, while the field of view (FOV) is divided into hundreds of thousands of small voxels. These two characteristics have a significant impact on the number of elements to be calculated in the SRM. Monte Carlo (MC) methods have gained popularity as a way of calculating the SRM, due to the increased accuracy achievable, at the cost of introducing some statistical noise and long simulation times. In the work presented here the SRM is calculated using MC methods exploiting the cylindrical symmetries of the scanner, significantly reducing the simulation time necessary to calculate a high statistical quality SRM and the storage space necessary. The use of cylindrical symmetries makes polar voxels a convenient basis function. Alternatively, spherically symmetric basis functions result in improved noise properties compared to cubic and polar basis functions. The quality of reconstructed images using polar voxels, spherically symmetric basis functions on a polar grid, cubic voxels and post-reconstruction filtered polar and cubic voxels is compared from a noise and spatial resolution perspective. This study demonstrates that polar voxels perform as well as cubic voxels, reducing the simulation time necessary to calculate the SRM and the disk space necessary to store it. Results showed that spherically symmetric functions outperform polar and cubic basis functions in terms of noise properties, at the cost of slightly degraded spatial resolution, larger SRM file size and longer reconstruction times. However, we demonstrate that post-reconstruction smoothing, usually applied in emission imaging to reduce the level of noise, can produce a spatial resolution degradation of similar to 50%, while spherically symmetric basis functions produce a degradation of only similar to 6%, compared to polar and cubic voxels, at the same noise level. Therefore, the image quality trade-off obtained with blobs is higher than that obtained with cubic or polar voxels.
|
|
|
Blume, M., Navab, N., & Rafecas, M. (2012). Joint image and motion reconstruction for PET using a B-spline motion model. Phys. Med. Biol., 57(24), 22pp.
Abstract: We present a novel joint image and motion reconstruction method for PET. The method is based on gated data and reconstructs an image together with amotion function. The motion function can be used to transform the reconstructed image to any of the input gates. All available events (from all gates) are used in the reconstruction. The presented method uses a B-spline motion model, together with a novel motion regularization procedure that does not need a regularization parameter (which is usually extremely difficult to adjust). Several image and motion grid levels are used in order to reduce the reconstruction time. In a simulation study, the presented method is compared to a recently proposed joint reconstruction method. While the presented method provides comparable reconstruction quality, it is much easier to use since no regularization parameter has to be chosen. Furthermore, since the B-spline discretization of the motion function depends on fewer parameters than a displacement field, the presented method is considerably faster and consumes less memory than its counterpart. The method is also applied to clinical data, for which a novel purely data-driven gating approach is presented.
|
|