ATLAS Collaboration(Aad, G. et al), Aikot, A., Amos, K. R., Aparisi Pozo, J. A., Bailey, A. J., Bouchhar, N., et al. (2024). Measurement of the Centrality Dependence of the Dijet Yield in p plus Pb Collisions at √sNN=8.16 TeV with the ATLAS Detector. Phys. Rev. Lett., 132(10), 102301–22pp.
Abstract: ATLAS measured the centrality dependence of the dijet yield using 165 nb-1 of p + Pb data collected at root sNN = 8.16 TeV in 2016. The event centrality, which reflects the p + Pb impact parameter, is characterized by the total transverse energy registered in the Pb-going side of the forward calorimeter. The central-to-peripheral ratio of the scaled dijet yields, RCP, is evaluated, and the results are presented as a function of variables that reflect the kinematics of the initial hard parton scattering process. The RCP shows a scaling with the Bjorken x of the parton originating from the proton, xp, while no such trend is observed as a function of xPb. This analysis provides unique input to understanding the role of small proton spatial configurations in p + Pb collisions by covering parton momentum fractions from the valence region down to xp similar to 10-3 and xPb similar to 4 x 10-4.
|
LHCb Collaboration(Aaij, R. et al), Jaimes Elles, S. J., Jashal, B. K., Martinez-Vidal, F., Oyanguren, A., Rebollo De Miguel, M., et al. (2024). Improved Measurement of CP Violation Parameters in B0s → J/ψ K+ K- Decays in the Vicinity of the φ(1020) Resonance. Phys. Rev. Lett., 132(5), 051802–12pp.
Abstract: The decay-time-dependent CP asymmetry in B0s -> J=psi(-> mu+mu-)K+K- decays is measured using proton-proton collision data, corresponding to an integrated luminosity of 6 fb-1, collected with the LHCb detector at a center-of-mass energy of 13 TeV. Using a sample of approximately 349 000 B0s signal decays with an invariant K+K- mass in the vicinity of the phi(1020) resonance, the CP-violating phase phi s is measured, along with the difference in decay widths of the light and heavy mass eigenstates of the B0s-B over bar 0s system, Delta Gamma s, and the difference of the average B0s and B0 meson decay widths, Gamma s – Gamma d. The values obtained are phi s = -0.039 +/- 0.022 +/- 0.006 rad, Delta Gamma s = 0.0845 +/- 0.0044 +/- 0.0024 ps-1, and -0.0015 +/- 0.0014 ps-1, where the first uncertainty is statistical and the second systematic. These are the most precise single measurements to date and are consistent with expectations based on the Standard Model and with the previous LHCb analyses of this decay. These results are combined with previous independent LHCb measurements. The phase phi s is also measured independently for each polarization state of the K+K- system and shows no evidence for polarization dependence.
|
ATLAS Collaboration(Aad, G. et al), Aikot, A., Amos, K. R., Aparisi Pozo, J. A., Bailey, A. J., Bouchhar, N., et al. (2024). Study of High-Transverse-Momentum Higgs Boson Production in Association with a Vector Boson in the qqbb Final State with the ATLAS Detector. Phys. Rev. Lett., 132(13), 131802–23pp.
Abstract: This Letter presents the first study of Higgs boson production in association with a vector boson (V = W or Z) in the fully hadronic qqbb final state using data recorded by the ATLAS detector at the LHC in ffiffiproton-proton collisions at root root s= 13 TeV and corresponding to an integrated luminosity of 137fb(-1). The vector bosons and Higgs bosons are each reconstructed as large-radius jets and tagged using jet substructure techniques. Dedicated tagging algorithms exploiting b-tagging properties are used to identify jets consistent with Higgs bosons decaying into b (b) over bar. Dominant backgrounds from multijet production are determined directly from the data, and a likelihood fit to the jet mass distribution of Higgs boson candidates is used to extract the number of signal events. The VH production cross section is measured inclusively and differentially in several ranges of Higgs boson transverse momentum: 250-450, 450-650, and greater than 650 GeV. The inclusive signal yield relative to the standard model expectation is observed to be μ= 1.4(-0.9)(+1.0) and the corresponding cross section is 3.1 +/- 1.3(stat)(-1.4)(+1.8) (syst) pb.
|
LHCb Collaboration(Aaij, R. et al), Jaimes Elles, S. J., Jashal, B. K., Martinez-Vidal, F., Oyanguren, A., Rebollo De Miguel, M., et al. (2024). Amplitude Analysis of the B0 -> K*0 μ+μ- Decay. Phys. Rev. Lett., 132(13), 131801–13pp.
Abstract: An amplitude analysis of the B-0 -> K*(0) mu(+)mu(-) decay is presented using a dataset corresponding to an integrated luminosity of 4.7 fb(-1) of pp collision data collected with the LHCb experiment. For the first time, the coefficients associated to short-distance physics effects, sensitive to processes beyond the standard model, are extracted directly from the data through a q(2)-unbinned amplitude analysis, where q(2) is the mu(+)mu(-) invariant mass squared. Long-distance contributions, which originate from nonfactorizable QCD processes, are systematically investigated, and the most accurate assessment to date of their impact on the physical observables is obtained. The pattern of measured corrections to the short-distance couplings is found to be consistent with previous analyses of b- to s-quark transitions, with the largest discrepancy from the standard model predictions found to be at the level of 1.8 standard deviations. The global significance of the observed differences in the decay is 1.4 standard deviations.
|
NA64 Collaboration(Andreev, Y. M. et al), Molina Bueno, L., & Tuzi, M. (2024). First Results in the Search for Dark Sectors at NA64 with the CERN SPS High Energy Muon Beam. Phys. Rev. Lett., 132(21), 211803–7pp.
Abstract: We report the first search for dark sectors performed at the NA64 experiment employing a high energy muon beam and a missing energy-momentum technique. Muons from the M2 beamline at the CERN Super Proton Synchrotron with a momentum of 160 GeV/c are directed to an active target. The signal signature consists of a single scattered muon with momentum < 80 GeV/c in the final state, accompanied by missing energy, i.e., no detectable activity in the downstream calorimeters. For a total dataset of (1.98 +/- 0.02) x 10(10) muons on target, no event is observed in the expected signal region. This allows us to set new limits on the remaining (m(Z)'; g(Z)') parameter space of a new Z' (L-mu – L-tau) vector boson which could explain the muon (g – 2)(mu) anomaly. Additionally, our study excludes part of the parameter space suggested by the thermal dark matter relic abundance. Our results pave the way to explore dark sectors and light dark matter with muon beams in a unique and complementary way to other experiments.
|
Jungclaus, A. et al, Gadea, A., & Montaner-Piza, A. (2024). Excited-State Half-Lives in 130 Cd and the Isospin Dependence of Effective Charges. Phys. Rev. Lett., 132(22), 222501–7pp.
Abstract: The known I pi = 8 & thorn; 1 , E x = 2129-keV isomer in the semimagic nucleus 130 Cd 82 was populated in the projectile fission of a 238 U beam at the Radioactive Isotope Beam Factory at RIKEN. The high counting statistics of the accumulated data allowed us to determine the excitation energy, E x = 2001.2(7) keV, and half-life, T 1 =2 = 57(3) ns, of the I pi = 6 & thorn; 1 state based on gamma gamma coincidence information. Furthermore, the halflife of the 8 & thorn; 1 state, T 1 =2 = 224(4) ns, was remeasured with high precision. The new experimental information, combined with available data for 134 Sn and large-scale shell model calculations, allowed us to extract proton and neutron effective charges for 132 Sn, a doubly magic nucleus far -off stability. A comparison to analogous information for 100 Sn provides first reliable information regarding the isospin dependence of the isoscalar and isovector effective charges in heavy nuclei.
|
Du, M. L., Filin, A., Baru, V., Dong, X. K., Epelbaum, E., Guo, F. K., et al. (2023). Role of Left-Hand Cut Contributions on Pole Extractions from Lattice Data: Case Study for Tcc(3875)+. Phys. Rev. Lett., 131(13), 131903–7pp.
Abstract: We discuss recent lattice data for the T-cc(3875)(+) state to stress, for the first time, a potentially strong impact of left-hand cuts from the one-pion exchange on the pole extraction for near-threshold exotic states. In particular, if the left-hand cut is located close to the two-particle threshold, which happens naturally in the DD* system for the pion mass exceeding its physical value, the effective-range expansion is valid only in a very limited energy range up to the cut and as such is of little use to reliably extract the poles. Then, an accurate extraction of the pole locations requires the one-pion exchange to be implemented explicitly into the scattering amplitudes. Our findings are general and potentially relevant for a wide class of hadronic near-threshold states.
|
Etxebeste, A., Barrio, J., Muñoz, E., Oliver, J. F., Solaz, C., & Llosa, G. (2016). 3D position determination in monolithic crystals coupled to SiPMs for PET. Phys. Med. Biol., 61(10), 3914–3934.
Abstract: The interest in using continuous monolithic crystals in positron emission tomography (PET) has grown in the last years. Coupled to silicon photomultipliers (SiPMs), the detector can combine high sensitivity and high resolution, the two main factors to be maximized in a positron emission tomograph. In this work, the position determination capability of a detector comprised of a 12 x 12 x 10 mm(3) LYSO crystal coupled to an 8 x 8-pixel array of SiPMs is evaluated. The 3D interaction position of.-rays is estimated using an analytical model of the light distribution including reflections on the facets of the crystal. Monte Carlo simulations have been performed to evaluate different crystal reflectors and geometries. The method has been characterized and applied to different cases. Intrinsic resolution obtained with the position estimation method used in this work, applied to experimental data, achieves sub-millimetre resolution values. Average resolution over the detector surface for 5 mm thick crystal is similar to 0.9 mm FWHM and similar to 1.2 mm FWHM for 10 mm thick crystal. Depth of interaction resolution is close to 2 mm FWHM in both cases, while the FWTM is similar to 5.3 mm for 5 mm thick crystal and similar to 9.6 mm for 10 mm thick crystal.
|
Solevi, P., Muñoz, E., Solaz, C., Trovato, M., Dendooven, P., Gillam, J. E., et al. (2016). Performance of MACACO Compton telescope for ion-beam therapy monitoring: first test with proton beams. Phys. Med. Biol., 61(14), 5149–5165.
Abstract: In order to exploit the advantages of ion-beam therapy in a clinical setting, delivery verification techniques are necessary to detect deviations from the planned treatment. Efforts are currently oriented towards the development of devices for real-time range monitoring. Among the different detector concepts proposed, Compton cameras are employed to detect prompt gammas and represent a valid candidate for real-time range verification. We present the first on-beam test of MACACO, a Compton telescope (multi-layer Compton camera) based on lanthanum bromide crystals and silicon photo-multipliers. The Compton telescope was first characterized through measurements and Monte Carlo simulations. The detector linearity was measured employing Na-22 and Am-Be sources, obtaining about 10% deviation from linearity at 3.44 MeV. A spectral image reconstruction algorithm was tested on synthetic data. Point-like sources emitting gamma rays with energy between 2 and 7 MeV were reconstructed with 3-5 mm resolution. The two-layer Compton telescope was employed to measure radiation emitted from a beam of 150 MeV protons impinging on a cylindrical PMMA target. Bragg-peak shifts were achieved via adjustment of the PMMA target location and the resulting measurements used during image reconstruction. Reconstructed Bragg peak profiles proved sufficient to observe peak-location differences within 10 mm demonstrating the potential of the MACACO Compton Telescope as a monitoring device for ion-beam therapy.
|
Muñoz, E., Barrio, J., Etxebeste, A., Ortega, P. G., Lacasta, C., Oliver, J. F., et al. (2017). Performance evaluation of MACACO: a multilayer Compton camera. Phys. Med. Biol., 62(18), 7321–7341.
Abstract: Compton imaging devices have been proposed and studied for a wide range of applications. We have developed a Compton camera prototype which can be operated with two or three detector layers based on monolithic lanthanum bromide (LaBr3) crystals coupled to silicon photomultipliers (SiPMs), to be used for proton range verification in hadron therapy. In this work, we present the results obtained with our prototype in laboratory tests with radioactive sources and in simulation studies. Images of a Na-22 and an Y-88 radioactive sources have been successfully reconstructed. The full width half maximum of the reconstructed images is below 4 mm for a Na-22 source at a distance of 5 cm.
|