Records |
Author |
Richard, J.M.; Valcarce, A.; Vijande, J. |
Title |
Pentaquarks with anticharm or beauty revisited |
Type |
Journal Article |
Year |
2019 |
Publication |
Physics Letters B |
Abbreviated Journal |
Phys. Lett. B |
Volume |
790 |
Issue |
|
Pages |
248-250 |
Keywords |
|
Abstract |
We use a constituent model to analyze the stability of pentaquark (Q) over bar qqqq configurations with a heavy antiquark (c) over bar or (b) over bar, and four light quarks uuds, ddsu or ssud. The interplay between chromoelectric and chromomagnetic effects is not favorable, and, as a consequence, no bound state is found below the lowest dissociation threshold. |
Address |
[Richard, Jean-Marc] Univ Lyon, Inst Phys Nucl Lyon, IN2P3, CNRS,UCBL, 4 Rue Enrico Fermi, F-69622 Villeurbanne, France, Email: j-m.richard@ipnl.in2p3.fr; |
Corporate Author |
|
Thesis |
|
Publisher |
Elsevier Science Bv |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN ![sorted by ISSN field, ascending order (up)](img/sort_asc.gif) |
0370-2693 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:000460118200028 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
yes |
Call Number |
IFIC @ pastor @ |
Serial |
3938 |
Permanent link to this record |
|
|
|
Author |
Hernandez, E.; Vijande, J.; Valcarce, A.; Richard, J.M. |
Title |
Spectroscopy, lifetime and decay modes of the T-bb(-) tetraquark |
Type |
Journal Article |
Year |
2020 |
Publication |
Physics Letters B |
Abbreviated Journal |
Phys. Lett. B |
Volume |
800 |
Issue |
|
Pages |
135073 - 9pp |
Keywords |
|
Abstract |
We present the first full-fledged study of the flavor-exotic isoscalar T-bb(-) equivalent to bb (u) over bar(d) over bar tetraquark with spin and parity J(P) = 1(+). We report accurate solutions of the four-body problem in a quark model, characterizing the structure of the state as a function of the ratio M-Q/m(q) of the heavy to light quark masses. For such a standard constituent model, T-bb(-) lies approximately 150 MeV below the strong decay threshold B- (B) over bar*(0) and 105 MeV below the electromagnetic decay threshold B- (B) over bar (0)gamma. We evaluate the lifetime of T-bb(-), identifying the promising decay modes where the tetraquark might be looked for in future experiments. Its total decay width is Gamma approximate to 87 x 10(-15) GeV and therefore its lifetime tau approximate to 7.6 ps. The promising final states are B*(-) D*(+) l (v) over bar (l) and (B) over bar*(0) l (v) over bar (l) among the semileptonic decays, and B*(-) D*(+) D-s*(-), (B) over bar*(0) D*(0) D-s*(-), and B*(-) D*(+) rho(-) among the nonleptonic ones. The semileptonic decay to the isoscalar J(P) = 0(+) tetraquark T-bc(0) is also relevant but it is not found to be dominant. There is a broad consensus about the existence of this tetraquark, and its detection will validate our understanding of the low-energy realizations of Quantum Chromodynamics (QCD) in the multiquark sector. |
Address |
[Hernandez, E.; Valcarce, A.] Univ Salamanca, Dept Fis Fundamental, E-37008 Salamanca, Spain, Email: gajatee@usal.es; |
Corporate Author |
|
Thesis |
|
Publisher |
Elsevier |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN ![sorted by ISSN field, ascending order (up)](img/sort_asc.gif) |
0370-2693 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:000503832500055 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
yes |
Call Number |
IFIC @ pastor @ |
Serial |
4240 |
Permanent link to this record |
|
|
|
Author |
Vijande, J.; Valcarce, A.; Carames, T.F.; Garcilazo, H. |
Title |
Heavy hadron spectroscopy: A quark model perspective |
Type |
Journal Article |
Year |
2013 |
Publication |
Nuclear Physics A |
Abbreviated Journal |
Nucl. Phys. A |
Volume |
914 |
Issue |
|
Pages |
472-481 |
Keywords |
Heavy hadrons; Constituent quark model; Many-quark systems |
Abstract |
We present recent results of hadron spectroscopy and hadron-hadron interaction from the perspective of constituent quark models. We pay special attention to the role played by higher order Fock space components in the hadron spectra and the connection of this extension with the hadron-hadron interaction. The main goal of our description is to obtain a coherent understanding of the low-energy hadron phenomenology without enforcing any particular model, to constrain its characteristics and learn about low-energy realization of the theory. |
Address |
[Vijande, J.] UV, Dept Fis Atom Mol & Nucl, Valencia, Spain, Email: javier.vijande@uv.es |
Corporate Author |
|
Thesis |
|
Publisher |
Elsevier Science Bv |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN ![sorted by ISSN field, ascending order (up)](img/sort_asc.gif) |
0375-9474 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:000324847700067 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
yes |
Call Number |
IFIC @ pastor @ |
Serial |
1599 |
Permanent link to this record |
|
|
|
Author |
Oliver, S.; Gimenez-Alventosa, V.; Berumen, F.; Gimenez, V.; Beaulieu, L.; Ballester, F.; Vijande, J. |
Title |
Benchmark of the PenRed Monte Carlo framework for HDR brachytherapy |
Type |
Journal Article |
Year |
2023 |
Publication |
Zeitschrift für Medizinische Physik |
Abbreviated Journal |
Z. Med. Phys. |
Volume |
33 |
Issue |
4 |
Pages |
511-528 |
Keywords |
Monte Carlo; PenRed; Brachytherapy; DICOM; Medical physics |
Abstract |
Purpose: The purpose of this study is to validate the PenRed Monte Carlo framework for clinical applications in brachytherapy. PenRed is a C++ version of Penelope Monte Carlo code with additional tallies and utilities. Methods and materials: Six benchmarking scenarios are explored to validate the use of PenRed and its improved bachytherapy-oriented capabilities for HDR brachytherapy. A new tally allowing the evaluation of collisional kerma for any material using the track length kerma estimator and the possibility to obtain the seed positions, weights and directions processing directly the DICOM file are now implemented in the PenRed distribution. The four non-clinical test cases developed by the Joint AAPM-ESTRO-ABG-ABS WG-DCAB were evaluated by comparing local and global absorbed dose differences with respect to established reference datasets. A prostate and a palliative lung cases, were also studied. For them, absorbed dose ratios, global absorbed dose differences, and cumulative dose-volume histograms were obtained and discussed. Results: The air-kerma strength and the dose rate constant corresponding to the two sources agree with the reference datatests within 0.3% (Sk) and 0.1% (K). With respect to the first three WG-DCAB test cases, more than 99.8% of the voxels present local (global) differences within +/- 1%(+/- 0.1%) of the reference datasets. For test Case 4 reference dataset, more than 94.9%(97.5%) of voxels show an agreement within +/- 1%(+/- 0.1%), better than similar benchmarking calculations in the literature. The track length kerma estimator scorer implemented increases the numerical efficiency of brachytherapy calculations two orders of magnitude, while the specific brachytherapy source allows the user to avoid the use of error-prone intermediate steps to translate the DICOM information into the simulation. In both clinical cases, only minor absorbed dose differences arise in the low-dose isodoses. 99.8% and 100% of the voxels have a global absorbed dose difference ratio within +/- 0.2%for the prostate and lung cases, respectively. The role played by the different segmentation and composition material in the bone structures was discussed, obtaining negligible absorbed dose differ-ences. Dose-volume histograms were in agreement with the reference data.Conclusions: PenRed incorporates new tallies and utilities and has been validated for its use for detailed and precise high-dose-rate brachytherapy simulations. |
Address |
[Oliver, S.] Univ Politecn Valencia, Inst Segur Ind, Radiofis & Medioambiental ISIRYM, Camide Vera s n, Valencia 46022, Spain, Email: sanolgi@upvnet.upv.es |
Corporate Author |
|
Thesis |
|
Publisher |
Elsevier |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN ![sorted by ISSN field, ascending order (up)](img/sort_asc.gif) |
0939-3889 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:001137118400001 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
yes |
Call Number |
IFIC @ pastor @ |
Serial |
5885 |
Permanent link to this record |
|
|
|
Author |
Pujades, M.C.; Granero, D.; Vijande, J.; Ballester, F.; Perez-Calatayud, J.; Papagiannis, P.; Siebert, F.A. |
Title |
Air-kerma evaluation at the maze entrance of HDR brachytherapy facilities |
Type |
Journal Article |
Year |
2014 |
Publication |
Journal of Radiological Protection |
Abbreviated Journal |
J. Radiol. Prot. |
Volume |
34 |
Issue |
4 |
Pages |
741-753 |
Keywords |
bunker; shielding; NCRP 151; brachytherapy; Monte Carlo |
Abstract |
In the absence of procedures for evaluating the design of brachytherapy (BT) facilities for radiation protection purposes, the methodology used for external beam radiotherapy facilities is often adapted. The purpose of this study is to adapt the NCRP 151 methodology for estimating the air-kerma rate at the door in BT facilities. Such methodology was checked against Monte Carlo (MC) techniques using the code Geant4. Five different facility designs were studied for Ir-192 and Co-60 HDR applications to account for several different bunker layouts. For the estimation of the lead thickness needed at the door, the use of transmission data for the real spectra at the door instead of the ones emitted by Ir-192 and Co-60 will reduce the lead thickness by a factor of five for Ir-192 and ten for Co-60. This will significantly lighten the door and hence simplify construction and operating requirements for all bunkers. The adaptation proposed in this study to estimate the air-kerma rate at the door depends on the complexity of the maze: it provides good results for bunkers with a maze (i.e. similar to those used for linacs for which the NCRP 151 methodology was developed) but fails for less conventional designs. For those facilities, a specific Monte Carlo study is in order for reasons of safety and cost-effectiveness. |
Address |
[Pujades, M. C.] Natl Ctr Dosimetry CND, Valencia, Spain, Email: mpuclau@gmail.com |
Corporate Author |
|
Thesis |
|
Publisher |
Iop Publishing Ltd |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN ![sorted by ISSN field, ascending order (up)](img/sort_asc.gif) |
0952-4746 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:000345895800005 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
yes |
Call Number |
IFIC @ pastor @ |
Serial |
2031 |
Permanent link to this record |