Records |
Author |
Zhao, X.; McLain, M.A.; Vijande, J.; Ferrando, A.; Carr, L.D.; Garcia-March, M.A. |
Title |
Nonequilibrium quantum dynamics of partial symmetry breaking for ultracold bosons in an optical lattice ring trap |
Type |
Journal Article |
Year |
2019 |
Publication |
New Journal of Physics |
Abbreviated Journal |
New J. Phys. |
Volume |
21 |
Issue |
|
Pages |
043042 - 13pp |
Keywords |
partial symmetry breaking; ultracold boson; ring trap; nonequilibrium quantum dynamics |
Abstract |
A vortex in a Bose-Einstein condensate on a ring undergoes quantum dynamics in response to a quantum quench in terms of partial symmetry breaking from a uniform lattice to a biperiodic one. Neither the current, a macroscopic measure, nor fidelity, a microscopic measure, exhibit critical behavior. Instead, the symmetry memory succeeds in identifying the critical symmetry breaking at which the system begins to forget its initial symmetry state. We further identify a symmetry energy difference in the low lying excited states which trends with the symmetry memory. |
Address |
[Zhao, Xinxin] Peking Univ, Int Ctr Quantum Mat, Sch Phys, Beijing 100871, Peoples R China, Email: zhaoxinxin@pku.edu.cn; |
Corporate Author |
|
Thesis |
|
Publisher |
Iop Publishing Ltd |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1367-2630 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:000465987600002 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
yes |
Call Number |
IFIC @ pastor @ |
Serial |
3995 |
Permanent link to this record |
|
|
|
Author |
Albiol, F.; Corbi, A.; Albiol, A. |
Title |
3D measurements in conventional X-ray imaging with RGB-D sensors |
Type |
Journal Article |
Year |
2017 |
Publication |
Medical Engineering & Physics |
Abbreviated Journal |
Med. Eng. Phys. |
Volume |
42 |
Issue |
|
Pages |
73-79 |
Keywords |
X-ray; Depth cameras; Epipolar geometry; 3D reconstruction; Movement tracking; Dense surface mapping |
Abstract |
A method for deriving 3D internal information in conventional X-ray settings is presented. It is based on the combination of a pair of radiographs from a patient and it avoids the use of X-ray-opaque fiducials and external reference structures. To achieve this goal, we augment an ordinary X-ray device with a consumer RGB-D camera. The patient' s rotation around the craniocaudal axis is tracked relative to this camera thanks to the depth information provided and the application of a modern surface-mapping algorithm. The measured spatial information is then translated to the reference frame of the X-ray imaging system. By using the intrinsic parameters of the diagnostic equipment, epipolar geometry, and X-ray images of the patient at different angles, 3D internal positions can be obtained. Both the RGB-D and Xray instruments are first geometrically calibrated to find their joint spatial transformation. The proposed method is applied to three rotating phantoms. The first two consist of an anthropomorphic head and a torso, which are filled with spherical lead bearings at precise locations. The third one is made of simple foam and has metal needles of several known lengths embedded in it. The results show that it is possible to resolve anatomical positions and lengths with a millimetric level of precision. With the proposed approach, internal 3D reconstructed coordinates and distances can be provided to the physician. It also contributes to reducing the invasiveness of ordinary X-ray environments and can replace other types of clinical explorations that are mainly aimed at measuring or geometrically relating elements that are present inside the patient's body. |
Address |
[Albiol, Francisco; Corbi, Alberto] Univ Valencia, CSIC, Inst Fis Corpuscular, E-46003 Valencia, Spain, Email: alberto.corbi@ific.uv.es |
Corporate Author |
|
Thesis |
|
Publisher |
Elsevier Sci Ltd |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1350-4533 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:000398007100008 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
no |
Call Number |
IFIC @ pastor @ |
Serial |
3043 |
Permanent link to this record |
|
|
|
Author |
Baron, R.; Boucaud, P.; Dimopoulos, P.; Frezzotti, R.; Palao, D.; Rossi, G.; Farchioni, F.; Munster, G.; Sudmann, T.; Gimenez, V.; Herdoiza, G.; Jansen, K.; Lubicz, V.; Simula, S.; Michael, C.; Scorzato, L.; Shindler, A.; Urbach, C.; Wenger, U. |
Title |
Light meson physics from maximally twisted mass lattice QCD |
Type |
Journal Article |
Year |
2010 |
Publication |
Journal of High Energy Physics |
Abbreviated Journal |
J. High Energy Phys. |
Volume |
08 |
Issue |
8 |
Pages |
097 - 41pp |
Keywords |
Lattice QCD; Quark Masses and SM Parameters; QCD |
Abstract |
We present a comprehensive investigation of light meson physics using maximally twisted mass fermions for N-f = 2 mass-degenerate quark flavours. By employing four values of the lattice spacing, spatial lattice extents ranging from 2.0 fm to 2.5 fm and pseudo scalar masses in the range 280 less than or similar to m(PS) less than or similar to 650MeV we control the major systematic effects of our calculation. This enables us to confront our N-f = 2 data with SU(2) chiral perturbation theory and extract low energy constants of the effective chiral Lagrangian and derived quantities, such as the light quark mass. |
Address |
[Baron, Remi; Boucaud, Phillip] Univ Paris 11, Phys Theor Lab, Ctr Orsay, F-91405 Orsay, France, Email: remi.baron@centraliens.net |
Corporate Author |
|
Thesis |
|
Publisher |
Springer |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1126-6708 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
ISI:000282367800036 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
yes |
Call Number |
IFIC @ elepoucu @ |
Serial |
348 |
Permanent link to this record |
|
|
|
Author |
Barrientos, L.; Borja-Lloret, M.; Casaña, J.V.; Dendooven, P.; Garcia Lopez, J.G.; Hueso-Gonzalez, F.; Jiméeez-Ramos, M.C.; Perez-Curbelo, J.; Ros, A.; Roser, J.; Senra, C.; Viegas, R.; Llosa, G. |
Title |
Gamma-ray sources imaging and test-beam results with MACACO III Compton camera |
Type |
Journal Article |
Year |
2024 |
Publication |
Physica Medica |
Abbreviated Journal |
Phys. Medica |
Volume |
117 |
Issue |
|
Pages |
103199 - 10pp |
Keywords |
Hadron therapy; Compton camera; Scintillator crystals; Silicon photomultipliers |
Abstract |
Hadron therapy is a radiotherapy modality which offers a precise energy deposition to the tumors and a dose reduction to healthy tissue as compared to conventional methods. However, methods for real-time monitoring are required to ensure that the radiation dose is deposited on the target. The IRIS group of IFIC-Valencia developed a Compton camera prototype for this purpose, intending to image the Prompt Gammas emitted by the tissue during irradiation. The system detectors are composed of Lanthanum (III) bromide scintillator crystals coupled to silicon photomultipliers. After an initial characterization in the laboratory, in order to assess the system capabilities for future experiments in proton therapy centers, different tests were carried out in two facilities: PARTREC (Groningen, The Netherlands) and the CNA cyclotron (Sevilla, Spain). Characterization studies performed at PARTREC indicated that the detectors linearity was improved with respect to the previous version and an energy resolution of 5.2 % FWHM at 511 keV was achieved. Moreover, the imaging capabilities of the system were evaluated with a line source of 68Ge and a point-like source of 241Am-9Be. Images at 4.439 MeV were obtained from irradiation of a graphite target with an 18 MeV proton beam at CNA, to perform a study of the system potential to detect shifts at different intensities. In this sense, the system was able to distinguish 1 mm variations in the target position at different beam current intensities for measurement times of 1800 and 600 s. |
Address |
[Barrientos, L.; Borja-Lloret, M.; Casana, J. V.; Hueso-Gonzalez, F.; Perez-Curbelo, J.; Ros, A.; Roser, J.; Senra, C.; Viegas, R.; Llosa, G.] CSIC UV, Inst Fis Corpuscular IFIC, Valencia, Spain, Email: Luis.Barrientos@ific.uv.es |
Corporate Author |
|
Thesis |
|
Publisher |
Elsevier Sci Ltd |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1120-1797 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:001145147400001 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
yes |
Call Number |
IFIC @ pastor @ |
Serial |
5892 |
Permanent link to this record |
|
|
|
Author |
LHCb Collaboration (Aaij, R. et al); Martinez-Vidal, F.; Oyanguren, A.; Ruiz Valls, P.; Sanchez Mayordomo, C. |
Title |
Measurement of the CKM angle gamma using B-+/- -> DK +/- with D -> K-S(0)pi(+)pi(-), (KSK+K-)-K-0 decays |
Type |
Journal Article |
Year |
2014 |
Publication |
Journal of High Energy Physics |
Abbreviated Journal |
J. High Energy Phys. |
Volume |
10 |
Issue |
10 |
Pages |
097 - 52pp |
Keywords |
CP violation; CKM angle gamma; Hadron-Hadron Scattering; B physics; Flavor physics |
Abstract |
A binned Dalitz plot analysis of B-+/- -> DK +/- decays, with D -> K-S(0) pi(+)pi(-) and D -> K0 S K + K -, is performed to measure the C P -violating observables x(+/-) and y(+/-), which are sensitive to the Cabibbo-Kobayashi-Maskawa angle gamma. The analysis exploits a sample of proton-proton collision data corresponding to 3.0 fb(-1) collected by the LHCb experiment. Measurements from CLEO-c of the variation of the strong-interaction phase of the D decay over the Dalitz plot are used as inputs. The values of the parameters are found to be x(+) = (-7.7 +/- 2.4 +/- 1.0 +/- 0.4) x 10(-2), x(-) = (2.5 +/- 2.5 +/- 1.0 +/- 0.5) x 10(-2), y(+) = (-2.2 +/- 2.5 +/- 0.4 +/- 1.0) x 10-2, and y(-) = (7.5 +/- 2.9 +/- 0.5 +/- 1.4) x 10(-2). The first, second, and third uncertainties are the statistical, the experimental systematic, and that associated with the precision of the strong-phase parameters. These are the most precise measurements of these observables and correspond to +/- = (62(-14)(+15))degrees, with a second solution at gamma -> gamma + 180 degrees, and r(B) = 0.080(-0.021)(+0.019), where r(B) is the ratio between the suppressed and favoured B decay amplitudes. |
Address |
[Bediaga, I.; De Miranda, J. M.; Ferreira Rodrigues, F.; Gomes, A.; Hicheur, A.; Massafferri, A.; dos Reis, A. C.; Rodrigues, A. B.] Ctr Brasileiro Pesquisas Fis, Rio De Janeiro, Brazil, Email: s.malde1@physics.ox.ac.uk |
Corporate Author |
|
Thesis |
|
Publisher |
Springer |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1029-8479 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:000344077300001 |
Approved |
no |
Is ISI |
yes |
International Collaboration |
yes |
Call Number |
IFIC @ pastor @ |
Serial |
1981 |
Permanent link to this record |