LHCb Collaboration(Aaij, R. et al), Jashal, B. K., Martinez-Vidal, F., Oyanguren, A., Remon Alepuz, C., & Ruiz Vidal, J. (2022). Constraints on the CKM angle gamma from B-+/- -> Dh(+/-) decays using D -> h(+/-)h '(-/+)pi(0) final states. J. High Energy Phys., 07(7), 099–24pp.
Abstract: A data sample collected with the LHCb detector corresponding to an integrated luminosity of 9 fb(-1) is used to measure eleven CP violation observables in B-+/- -> Dh(+/-) decays, where h is either a kaon or a pion. The neutral D meson decay is reconstructed in the three-body final states: K-+/-pi(-/+)pi(0); pi(+)pi(-)pi(0); K+ K- pi(0) and the suppressed pi K-+(-/+)pi(0) combination. The mode where a large CP asymmetry is expected, B-+/- -> [K-+/-pi(-/+)pi(0)] K-D(+/-), is observed with a significance greater than seven standard deviations. The ratio of the partial width of this mode relative to that of the favoured mode, B-+/- -> [K-+/-pi(-/+)pi(0)] K-D(+/-), is R-ADS(K) = (1.27 +/- 0.16 +/- 0.02) x 10(-2). Evidence for a large CP asymmetry is also seen: A(ADS(K)) = – 0.38 +/- 0.12 +/- 0.02. Constraints on the CKM angle gamma are calculated from the eleven reported observables.
|
HAWC Collaboration(Albert, A. et al), & Salesa Greus, F. (2022). Probing the Extragalactic Mid-infrared Background with HAWC. Astrophys. J., 933(2), 223–8pp.
Abstract: The extragalactic background light (EBL) contains all the radiation emitted by nuclear and accretion processes in stars and compact objects since the epoch of recombination. Measuring the EBL density directly is challenging, especially in the near-to-far-infrared wave band, mainly due to the zodiacal light foreground. Instead, gamma-ray astronomy offers the possibility to indirectly set limits on the EBL by studying the effects of gamma-ray absorption in the very high energy (VHE: >100 GeV) spectra of distant blazars. The High Altitude Water Cherenkov Gamma Ray Observatory (HAWC) is one of the few instruments sensitive to gamma rays with energies above 10 TeV. This offers the opportunity to probe the EBL in the near/mid-IR region: lambda = 1-100 μm. In this study, we fit physically motivated emission models to Fermi-LAT gigaelectronvolt data to extrapolate the intrinsic teraelectronvolt spectra of blazars. We then simulate a large number of absorbed spectra for different randomly generated EBL model shapes and calculate Bayesian credible bands in the EBL intensity space by comparing and testing the agreement between the absorbed spectra and HAWC extragalactic observations of two blazars. The resulting bands are in agreement with current EBL lower and upper limits, showing a downward trend toward higher wavelength values lambda > 10 μm also observed in previous measurements.
|
ATLAS Collaboration(Aad, G. et al), Alvarez Piqueras, D., Aparisi Pozo, J. A., Bailey, A. J., Cabrera Urban, S., Castillo, F. L., et al. (2022). Two-particle Bose-Einstein correlations in pp collisions at root s=13 TeV measured with the ATLAS detector at the LHC. Eur. Phys. J. C, 82(7), 608–38pp.
Abstract: This paper presents studies of Bose-Einstein correlations (BEC) in proton-proton collisions at a centre-of-mass energy of 13 TeV, using data from the ATLAS detector at the CERN Large Hadron Collider. Data were collected in a special low-luminosity configuration with a minimum-bias trigger and a high-multiplicity track trigger, accumulating integrated luminosities of 151 μb(-1) and 8.4 nb(-1), respectively. The BEC are measured for pairs of like-sign charged particles, each with vertical bar eta vertical bar < 2.5, for two kinematic ranges: the first with particle pr > 100 MeV and the second with particle pr > 500 MeV. The BEC parameters, characterizing the source radius and particle correlation strength, are investigated as functions of charged-particle multiplicity (up to 300) and average transverse momentum of the pair (up to 1.5 GeV). The double-differential dependence on charged-particle multiplicity and average transverse momentum of the pair is also studied. The BEC radius is found to be independent of the charged-particle multiplicity for high charged-particle multiplicity (above 100), confirming a previous observation at lower energy. This saturation occurs independent of the transverse momentum of the pair.
|
ATLAS Collaboration(Aad, G. et al), Aparisi Pozo, J. A., Bailey, A. J., Cabrera Urban, S., Cardillo, F., Castillo Gimenez, V., et al. (2022). Search for long-lived charginos based on a disappearing-track signature using 136 fb(-1) of pp collisions at root s=13 TeV with the ATLAS detector. Eur. Phys. J. C, 82(7), 606–34pp.
Abstract: A search for long-lived charginos produced either directly or in the cascade decay of heavy prompt gluino states is presented. The search is based on proton- proton collision data collected at a centre-of-mass energy of root s = 13 TeV between 2015 and 2018 with the ATLAS detector at the LHC, corresponding to an integrated luminosity of 136 fb(-1). Long-lived charginos are characterised by a distinct signature of a short and then disappearing track, and are reconstructed using at least four measurements in the ATLAS pixel detector, with no subsequent measurements in the silicon-microstrip tracking volume nor any associated energy deposits in the calorimeter. The final state is complemented by a large missing transverse-momentum requirement for triggering purposes and at least one high-transversemomentum jet. No excess above the expected backgrounds is observed. Exclusion limits are set at 95% confidence level on the masses of the chargino and gluino for different chargino lifetimes. Chargino masses up to 660 (210) GeV are excluded in scenarios where the chargino is a pure wino (higgsino). For charginos produced during the cascade decay of a heavy gluino, gluinos with masses below 2.1 TeV are excluded for a chargino mass of 300 GeV and a lifetime of 0.2 ns.
|
Roser, J., Barrientos, L., Bernabeu, J., Borja-Lloret, M., Muñoz, E., Ros, A., et al. (2022). Joint image reconstruction algorithm in Compton cameras. Phys. Med. Biol., 67(15), 155009–15pp.
Abstract: Objective. To demonstrate the benefits of using an joint image reconstruction algorithm based on the List Mode Maximum Likelihood Expectation Maximization that combines events measured in different channels of information of a Compton camera. Approach. Both simulations and experimental data are employed to show the algorithm performance. Main results. The obtained joint images present improved image quality and yield better estimates of displacements of high-energy gamma-ray emitting sources. The algorithm also provides images that are more stable than any individual channel against the noisy convergence that characterizes Maximum Likelihood based algorithms. Significance. The joint reconstruction algorithm can improve the quality and robustness of Compton camera images. It also has high versatility, as it can be easily adapted to any Compton camera geometry. It is thus expected to represent an important step in the optimization of Compton camera imaging.
|
LHCb Collaboration(Aaij, R. et al), Jashal, B. K., Martinez-Vidal, F., Oyanguren, A., Remon Alepuz, C., & Ruiz Vidal, J. (2022). Precision measurement of forward Z boson production in proton-proton collisions at root s=13 TeV. J. High Energy Phys., 07(7), 026–57pp.
Abstract: A precision measurement of the Z boson production cross-section at root s = 13 TeV in the forward region is presented, using pp collision data collected by the LHCb detector, corresponding to an integrated luminosity of 5.1 fb(-1). The production cross-section is measured using Z -> mu(+)mu(-) events within the fiducial region defined as pseudorapidity 2.0 < eta < 4.5 and transverse momentum p(T) > 20 GeV/c for both muons and dimuon invariant mass 60 < M-mu μ< 120 GeV/c(2). The integrated cross-section is determined to be sigma(Z -> mu(+)mu(-)) = 196.4 +/- 0.2 +/- 1.6 +/- 3.9 pb, where the first uncertainty is statistical, the second is systematic, and the third is due to the luminosity determination. The measured results are in agreement with theoretical predictions within uncertainties.
|
Mandal, S., Miranda, O. G., Sanchez Garcia, G., Valle, J. W. F., & Xu, X. J. (2022). High-energy colliders as a probe of neutrino properties. Phys. Lett. B, 829, 137110–5pp.
Abstract: The mediators of neutrino mass generation can provide a probe of neutrino properties at the next round of high-energy hadron (FCC-hh) and lepton colliders (FCC-ee/ILC/CEPC/CLIC). We show how the decays of the Higgs triplet scalars mediating the simplest seesaw mechanism can shed light on the neutrino mass scale and mass-ordering, as well as the atmospheric octant. Four-lepton signatures at the high-energy frontier may provide the discovery-site for charged lepton flavor non-conservation in nature, rather than low-energy intensity frontier experiments.
|
Albiol, A., Albiol, F., Paredes, R., Plasencia-Martinez, J. M., Blanco Barrio, A., Garcia Santos, J. M., et al. (2022). A comparison of Covid-19 early detection between convolutional neural networks and radiologists. Insights Imaging, 13(1), 122–12pp.
Abstract: Background The role of chest radiography in COVID-19 disease has changed since the beginning of the pandemic from a diagnostic tool when microbiological resources were scarce to a different one focused on detecting and monitoring COVID-19 lung involvement. Using chest radiographs, early detection of the disease is still helpful in resource-poor environments. However, the sensitivity of a chest radiograph for diagnosing COVID-19 is modest, even for expert radiologists. In this paper, the performance of a deep learning algorithm on the first clinical encounter is evaluated and compared with a group of radiologists with different years of experience. Methods The algorithm uses an ensemble of four deep convolutional networks, Ensemble4Covid, trained to detect COVID-19 on frontal chest radiographs. The algorithm was tested using images from the first clinical encounter of positive and negative cases. Its performance was compared with five radiologists on a smaller test subset of patients. The algorithm's performance was also validated using the public dataset COVIDx. Results Compared to the consensus of five radiologists, the Ensemble4Covid model achieved an AUC of 0.85, whereas the radiologists achieved an AUC of 0.71. Compared with other state-of-the-art models, the performance of a single model of our ensemble achieved nonsignificant differences in the public dataset COVIDx. Conclusion The results show that the use of images from the first clinical encounter significantly drops the detection performance of COVID-19. The performance of our Ensemble4Covid under these challenging conditions is considerably higher compared to a consensus of five radiologists. Artificial intelligence can be used for the fast diagnosis of COVID-19.
|
Pich, A., & Rodriguez-Sanchez, A. (2022). Violations of quark-hadron duality in low-energy determinations of alpha(s). J. High Energy Phys., 07(7), 145–42pp.
Abstract: Using the spectral functions measured in tau decays, we investigate the actual numerical impact of duality violations on the extraction of the strong coupling. These effects are tiny in the standard alpha(s)(m(tau)(2)) determinations from integrated distributions of the hadronic spectrum with pinched weights, or from the total tau hadronic width. The pinched-weight factors suppress very efficiently the violations of duality, making their numerical effects negligible in comparison with the larger perturbative uncertainties. However, combined fits of alpha(s) and duality-violation parameters, performed with non-protected weights, are subject to large systematic errors associated with the assumed modelling of duality-violation effects. These uncertainties have not been taken into account in the published analyses, based on specific models of quark-hadron duality.
|
Otal, A., Celada, F., Chimeno, J., Vijande, J., Pellejero, S., Perez-Calatayud, M. J., et al. (2022). Review on Treatment Planning Systems for Cervix Brachytherapy (Interventional Radiotherapy): Some Desirable and Convenient Practical Aspects to Be Implemented from Radiation Oncologist and Medical Physics Perspectives. Cancers, 14(14), 3467–15pp.
Abstract: Simple Summary There are no brachytherapy treatment planning systems (TPS) exclusively for the treatment of cervical tumours, so general-purpose TPSs are used. However, these treatments have some particular features concerning the treatment of other pathologies, especially in the case of exclusive use of MRI as an imaging modality and the presence of gynaecological applicators in combination with an interstitial part. That is why it is essential to review the latest versions of commercial TPSs to find the potential features to improve with the help of a group of experimented medical physicists and radiation oncologists. Furthermore, after reviewing the recent literature for advances applicable to cervical brachytherapy and through his own clinical experience, possible improvements are proposed to software providers for the development of new tools. Intracavitary brachytherapy (BT, Interventional Radiotherapy, IRT), plays an essential role in the curative intent of locally advanced cervical cancer, for which the conventional approach involves external beam radiotherapy with concurrent chemotherapy followed by BT. This work aims to review the different methodologies used by commercially available treatment planning systems (TPSs) in exclusive magnetic resonance imaging-based (MRI) cervix BT with interstitial component treatments. Practical aspects and improvements to be implemented into the TPSs are discussed. This review is based on the clinical expertise of a group of radiation oncologists and medical physicists and on interactive demos provided by the software manufacturers. The TPS versions considered include all the new tools currently in development for future commercial releases. The specialists from the supplier companies were asked to propose solutions to some of the challenges often encountered in a clinical environment through a questionnaire. The results include not only such answers but also comments by the authors that, in their opinion, could help solve the challenges covered in these questions. This study summarizes the possibilities offered nowadays by commercial TPSs, highlighting the absence of some useful tools that would notably improve the planning of MR-based interstitial component cervix brachytherapy.
|