|
Hajjar, R., Palomares-Ruiz, S., & Mena, O. (2024). Shedding light on the Δm21^2 tension with supernova neutrinos. Phys. Lett. B, 854, 138719–8pp.
Abstract: One long-standing tension in the determination of neutrino parameters is the mismatched value of the solar mass square difference, Delta m(21)(2), measured by different experiments: the reactor antineutrino experiment KamLAND finds a best fit larger than the one obtained with solar neutrino data. Even if the current tension is mild (similar to 1.5 sigma.), it is timely to explore if independent measurements could help in either closing or reassessing this issue. In this regard, we explore how a future supernova burst in our galaxy could be used to determine Delta m(21)(2) at the future Hyper-Kamiokande detector, and how this could contribute to the current situation. We study Earth matter effects for different models of supernova neutrino spectra and supernova orientations. We find that, if supernova neutrino data prefers the KamLAND best fit for Delta m(21)(2), an uncertainty similar to the current KamLAND one could be achieved. On the contrary, if it prefers the solar neutrino data best fit, the current tension with KamLAND results could grow to a significance larger than 5 sigma. Furthermore, supernova neutrinos could significantly contribute to reducing the uncertainty on sin (2)theta(12).
|
|
|
Jungclaus, A. et al, Gadea, A., & Montaner-Piza, A. (2024). Excited-State Half-Lives in 130 Cd and the Isospin Dependence of Effective Charges. Phys. Rev. Lett., 132(22), 222501–7pp.
Abstract: The known I pi = 8 & thorn; 1 , E x = 2129-keV isomer in the semimagic nucleus 130 Cd 82 was populated in the projectile fission of a 238 U beam at the Radioactive Isotope Beam Factory at RIKEN. The high counting statistics of the accumulated data allowed us to determine the excitation energy, E x = 2001.2(7) keV, and half-life, T 1 =2 = 57(3) ns, of the I pi = 6 & thorn; 1 state based on gamma gamma coincidence information. Furthermore, the halflife of the 8 & thorn; 1 state, T 1 =2 = 224(4) ns, was remeasured with high precision. The new experimental information, combined with available data for 134 Sn and large-scale shell model calculations, allowed us to extract proton and neutron effective charges for 132 Sn, a doubly magic nucleus far -off stability. A comparison to analogous information for 100 Sn provides first reliable information regarding the isospin dependence of the isoscalar and isovector effective charges in heavy nuclei.
|
|
|
Beltran, R., Günther, J., Hirsch, M., Titov, A., & Wang, Z. S. (2024). Heavy neutral leptons from kaons in effective field theory. Phys. Rev. D, 109(11), 115014–19pp.
Abstract: In the framework of the low -energy effective theory containing, in addition to the Standard -Model fields, heavy neutral leptons (HNLs), we compute the decay rates of neutral and charged kaons into HNLs. We consider both lepton -number -conserving and lepton -number -violating four-fermion operators, taking into account also the contribution of active -heavy neutrino mixing. Assuming that the produced HNLs are longlived, we perform simulations and calculate the sensitivities of future long -lived -particle (LLP) detectors at the high -luminosity LHC as well as the near detector of the Deep Underground Neutrino Experiment (DUNE -ND) to the considered scenario. When applicable, we also recast the existing bounds on the minimal mixing case obtained by NA62, T2K, and PS191. Our findings show that, while the future LHC LLP detectors can probe currently allowed parameter space only in certain benchmark scenarios, DUNE -ND should be sensitive to parameter space beyond the current bounds in almost all the benchmark scenarios, and, for some of the effective operators considered, it can even probe new -physics scales in excess of 3000 TeV.
|
|
|
Bhattacharya, S., Mondal, N., Roshan, R., & Vatsyayan, D. (2024). Leptogenesis, dark matter and gravitational waves from discrete symmetry breaking. J. Cosmol. Astropart. Phys., 06(6), 029–25pp.
Abstract: We analyse a model that connects the neutrino sector and the dark sector of the universe via a mediator 41., stabilised by a discrete Z4 symmetry that breaks to a remnant Z2 upon 41. acquiring a non -zero vacuum expectation value (v phi). The model accounts for the observed baryon asymmetry of the universe via additional contributions to the canonical Type -I leptogenesis. The Z4 symmetry breaking scale (v phi) in the model not only establishes a connection between the neutrino sector and the dark sector, but could also lead to gravitational wave signals that are within the reach of current and future experimental sensitivities.
|
|
|
Bach, E. et al, Bernabeu, J., Lacasta, C., Solaz, C., & Soldevila, U. (2024). Analysis of the quality assurance results from the initial part of production of the ATLAS18 ITK strip sensors. Nucl. Instrum. Methods Phys. Res. A, 1064, 169435–8pp.
Abstract: The production of strip sensors for the ATLAS Inner Tracker (ITk) started in 2021. Since then, a Quality Assurance (QA) program has been carried out continuously, by using specific test structures, in parallel to the Quality Control (QC) inspection of the sensors. The QA program consists of monitoring sensor-specific characteristics and the technological process variability, before and after the irradiation with gammas, neutrons, and protons. After two years, half of the full production volume has been reached and we present an analysis of the parameters measured as part of the QA process. The main devices used for QA purposes are miniature strip sensors, monitor diodes, and the ATLAS test chip, which contains several test structures. Such devices are tested by several sites across the collaboration depending on the type of samples (non-irradiated components or irradiated with protons, neutrons, or gammas). The parameters extracted from the tests are then uploaded to a database and analyzed by Python scripts. These parameters are mainly examined through histograms and timeevolution plots to obtain parameter distributions, production trends, and meaningful parameter-to-parameter correlations. The purpose of this analysis is to identify possible deviations in the fabrication or the sensor quality, changes in the behavior of the test equipment at different test sites, or possible variability in the irradiation processes. The conclusions extracted from the QA program have allowed test optimization, establishment of control limits for the parameters, and a better understanding of device properties and fabrication trends. In addition, any abnormal results prompt immediate feedback to a vendor.
|
|