Ibanez-Rosello, B., Bautista-Ballesteros, J. A., Candela-Juan, C., Villaescusa, J. I., Ballester, F., Vijande, J., et al. (2017). Evaluation of the shielding in a treatment room with an electronic brachytherapy unit. J. Radiol. Prot., 37(2), N5–N12.
Abstract: Esteya (R) (Elekta Brachytherapy, Veenendaal, The Netherlands) is an electronic brachytherapy (eBT) system based on a 69.5 kVp x-ray source and a set of collimators of 1 to 3 cm in diameter, used for treating non-melanoma skin cancer lesions. This study aims to estimate room shielding requirements for this unit. The non-primary (scattered and leakage) ambient dose equivalent rates were measured with a Berthold LB-133 monitor (Berthold Technologies, Bad Wildbad, Germany). The latter ranges from 17 mSv h(-1) at 0.25 m distance from the x-ray source to 0.1 mSv h(-1) at 2.5 m. The necessary room shielding was then estimated following US and some European guidelines. The room shielding for all barriers considered was below 2 mmPb. The dose to a companion who, exceptionally, would stay with the patient during all treatment was estimated to be below 1 mSv if a leaded apron is used. In conclusion, Esteya shielding requirements are minimal.
|
Caballero, L., Albiol, F., Corbi Bellot, A., Domingo-Pardo, C., Leganes Nieto, J. L., Agramunt Ros, J., et al. (2018). Gamma-ray imaging system for real-time measurements in nuclear waste characterisation. J. Instrum., 13, P03016–23pp.
Abstract: Acompact, portable and large field-of-viewgamma camera that is able to identify, locate and quantify gamma-ray emitting radioisotopes in real-time has been developed. The device delivers spectroscopic and imaging capabilities that enable its use it in a variety of nuclear waste characterisation scenarios, such as radioactivity monitoring in nuclear power plants and more specifically for the decommissioning of nuclear facilities. The technical development of this apparatus and some examples of its application in field measurements are reported in this article. The performance of the presented gamma-camera is also benchmarked against other conventional techniques.
|
Baeza-Ballesteros, J., Donini, A., & Nadal-Gisbert, S. (2022). Dynamical measurements of deviations from Newton's 1/r(2) law. Eur. Phys. J. C, 82(2), 154–30pp.
Abstract: In Ref. Donini and Marimon (Eur Phys J C 76:696, arXiv:1609.05654, 2016), an experimental setup aiming at the measurement of deviations from the Newtonian 1/r(2) distance dependence of gravitational interactions was proposed. The theoretical idea behind this setup was to study the trajectories of a “Satellite” with a mass m(S) similar to O(10(-9)) g around a “Planet” with mass m(P) is an element of [10(-7), 10(-5)] g, looking for precession of the orbit. The observation of such feature induced by gravitational interactions would be an unambiguous indication of a gravitational potential with terms different from 1/r and, thus, a powerful tool to detect deviations from Newton's 1/r(2) law. In this paper we optimize the proposed setup in order to achieve maximal sensitivity to look for such Beyond-Newtonian corrections. We then study in detail possible background sources that could induce precession and quantify their impact on the achievable sensitivity. We finally conclude that a dynamical measurement of deviations from newtonianity can test Yukawa-like corrections to the 1/r potential with strength as low as alpha similar to 10(-2) for distances as small as lambda similar to 10 μm.
|
Botella-Soler, V., Oteo, J. A., Ros, J., & Glendinning, P. (2013). Lyapunov exponent and topological entropy plateaus in piecewise linear maps. J. Phys. A, 46(12), 125101–26pp.
Abstract: We consider a two-parameter family of piecewise linear maps in which the moduli of the two slopes take different values. We provide numerical evidence of the existence of some parameter regions in which the Lyapunov exponent and the topological entropy remain constant. Analytical proof of this phenomenon is also given for certain cases. Surprisingly however, the systems with that property are not conjugate as we prove by using kneading theory.
|
Andrews, H. L., Taheri, F. B., Barros, J., Bartolini, R., Bharadwaj, V., Clarke, C., et al. (2014). Reconstruction of the time profile of 20.35 GeV, subpicosecond long electron bunches by means of coherent Smith-Purcell radiation. Phys. Rev. Spec. Top.-Accel. Beams, 17(5), 052802–13pp.
Abstract: We have used coherent Smith-Purcell radiation (cSPr) in order to determine the temporal profile of sub-ps long electron bunches at the Facility for Advanced Accelerator Experimental Tests, at SLAC. The measurements reported here were carried out in June 2012 and April 2013. The rms values for the bunch length varied between 356 to 604 fs, depending on the accelerator settings. The resolution of the system was limited by the range of detectable wavelengths which was, in turn, determined by the choice of the grating periods used in these experiments and the achievable beam-grating separation. The paper gives the details of the various steps in the reconstruction of the time profile and discusses possible improvements to the resolution. We also present initial measurements of the polarization properties of cSPr and of the background radiation.
|