Records |
Author |
Carrio, F.; Kim, H.Y.; Moreno, P.; Reed, R.; Sandrock, C.; Schettino, V.; Shalyugin, A.; Solans, C.; Souza, J.; Usai, G.; Valero, A. |
Title |
Design of an FPGA-based embedded system for the ATLAS Tile Calorimeter front-end electronics test-bench |
Type |
Journal Article |
Year |
2014 |
Publication |
Journal of Instrumentation |
Abbreviated Journal |
J. Instrum. |
Volume |
9 |
Issue |
|
Pages |
C03023 - 12pp |
Keywords |
Detector control systems (detector and experiment monitoring and slow-control systems, architecture, hardware, algorithms; databases); Data acquisition concepts; Digital electronic circuits |
Abstract |
The portable test-bench for the certification of the ATLAS tile hadronic calorimeter front-end electronics has been redesigned for the present Long Shutdown (LS1) of LHC, improving its portability and expanding its functionalities. This paper presents a new test-bench based on a Xilinx Virtex-5 FPGA that implements an embedded system using a PowerPC 440 microprocessor hard core and custom IP cores. A light Linux version runs on the PowerPC microprocessor and handles the IP cores which implement the different functionalities needed to perform the desired tests such as TTCvi emulation, G-Link decoding, ADC control and data reception. |
Address |
[Carrio, F.; Valero, A.] Univ Valencia, CSIC, Inst Fis Corpuscular, E-46980 Paterna, Spain, Email: fernando.carrio@cern.ch |
Corporate Author |
|
Thesis |
|
Publisher |
Iop Publishing Ltd |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1748-0221 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:000336123200023 |
Approved |
no |
Is ISI |
yes |
International Collaboration ![sorted by International Collaboration field, descending order (down)](img/sort_desc.gif) |
yes |
Call Number |
IFIC @ pastor @ |
Serial |
1801 |
Permanent link to this record |
|
|
|
Author |
Brzezinski, K.; Oliver, J.F.; Gillam, J.; Rafecas, M.; Studen, A.; Grkovski, M.; Kagan, H.; Smith, S.; Llosa, G.; Lacasta, C.; Clinthorne, N.H. |
Title |
Experimental evaluation of the resolution improvement provided by a silicon PET probe |
Type |
Journal Article |
Year |
2016 |
Publication |
Journal of Instrumentation |
Abbreviated Journal |
J. Instrum. |
Volume |
11 |
Issue |
|
Pages |
P09016 - 13pp |
Keywords |
Gamma camera; SPECT; PET PET/CT; coronary CT angiography (CTA); Medical-image reconstruction methods and algorithms; computer-aided software |
Abstract |
A high-resolution PET system, which incorporates a silicon detector probe into a conventional PET scanner, has been proposed to obtain increased image quality in a limited region of interest. Detailed simulation studies have previously shown that the additional probe information improves the spatial resolution of the reconstructed image and increases lesion detectability, with no cost to other image quality measures. The current study expands on the previous work by using a laboratory prototype of the silicon PET-probe system to examine the resolution improvement in an experimental setting. Two different versions of the probe prototype were assessed, both consisting of a back-to-back pair of 1-mm thick silicon pad detectors, one arranged in 32 x 16 arrays of 1.4mm x 1.4mm pixels and the other in 40 x 26 arrays of 1.0mm x 1.0mm pixels. Each detector was read out by a set of VATAGP7 ASICs and a custom-designed data acquisition board which allowed trigger and data interfacing with the PET scanner, itself consisting of BGO block detectors segmented into 8 x 6 arrays of 6mm x 12mm x 30mm crystals. Limited-angle probe data was acquired from a group of Na-22 point-like sources in order to observe the maximum resolution achievable using the probe system. Data from a Derenzo-like resolution phantom was acquired, then scaled to obtain similar statistical quality as that of previous simulation studies. In this case, images were reconstructed using measurements of the PET ring alone and with the inclusion of the probe data. Images of the Na-22 source demonstrated a resolution of 1.5mm FWHM in the probe data, the PET ring resolution being approximately 6 mm. Profiles taken through the image of the Derenzo-like phantom showed a clear increase in spatial resolution. Improvements in peak-to-valley ratios of 50% and 38%, in the 4.8mm and 4.0mm phantom features respectively, were observed, while previously unresolvable 3.2mm features were brought to light by the addition of the probe. These results support the possibility of improving the image resolution of a clinical PET scanner using the silicon PET-probe. |
Address |
[Brzezinski, K.; Oliver, J. F.; Gillam, J.; Rafecas, M.; Llosa, G.; Lacasta, C.] Univ Valencia, CSIC, Inst Fis Corpuscular, C Catedrat Jose Beltran 2, Valencia, Spain, Email: k.w.brzezinski@rug.nl |
Corporate Author |
|
Thesis |
|
Publisher |
Iop Publishing Ltd |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1748-0221 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:000387862300016 |
Approved |
no |
Is ISI |
yes |
International Collaboration ![sorted by International Collaboration field, descending order (down)](img/sort_desc.gif) |
yes |
Call Number |
IFIC @ pastor @ |
Serial |
2865 |
Permanent link to this record |
|
|
|
Author |
NEXT Collaboration (Simon, A. et al); Gomez-Cadenas, J. J.; Alvarez, V.; Benlloch-Rodriguez, J. M.; Botas, A.; Carcel, S.; Carrion, J.V.; Diaz, J.; Felkai, R.; Ferrario, P.; Laing, A.; Liubarsky, I.; Lopez-March, N.; Martin-Albo, J.; Martinez, A.; Muñoz Vidal, J.; Musti, M.; Nebot-Guinot, M.; Novella, P.; Palmeiro, B.; Perez, J.; Querol, M.; Renner, J.; Rodriguez, J.; Sorel, M.; Torrent, J.; Yahlali, N. |
Title |
Application and performance of an ML-EM algorithm in NEXT |
Type |
Journal Article |
Year |
2017 |
Publication |
Journal of Instrumentation |
Abbreviated Journal |
J. Instrum. |
Volume |
12 |
Issue |
|
Pages |
P08009 - 22pp |
Keywords |
Gaseous imaging and tracking detectors; Image reconstruction in medical imaging; Time projection Chambers (TPC); Medical-image reconstruction methods and algorithms; computer-aided software |
Abstract |
The goal of the NEXT experiment is the observation of neutrinoless double beta decay in Xe-136 using a gaseous xenon TPC with electroluminescent amplification and specialized photodetector arrays for calorimetry and tracking. The NEXT Collaboration is exploring a number of reconstruction algorithms to exploit the full potential of the detector. This paper describes one of them: the Maximum Likelihood Expectation Maximization (ML-EM) method, a generic iterative algorithm to find maximum-likelihood estimates of parameters that has been applied to solve many different types of complex inverse problems. In particular, we discuss a bi-dimensional version of the method in which the photosensor signals integrated over time are used to reconstruct a transverse projection of the event. First results show that, when applied to detector simulation data, the algorithm achieves nearly optimal energy resolution (better than 0.5% FWHM at the Q value of 136Xe) for events distributed over the full active volume of the TPC. |
Address |
[Simon, A.; Gomez-Cadenas, J. J.; Alvarez, V.; Benlloch-Rodriguez, J. M.; Botas, A.; Carcel, S.; Carrion, J. V.; Diaz, J.; Felkai, R.; Ferrario, P.; Laing, A.; Liubarsky, I.; Lopez-March, N.; Martin-Albo, J.; Martinez, A.; Munoz Vidal, J.; Musti, M.; Nebot-Guinot, M.; Novella, P.; Palmeiro, B.; Perez, J.; Querol, M.; Renner, J.; Rodriguez, J.; Sorel, M.; Torrent, J.; Yahlali, N.] CSIC, Inst Fis Corpuscular IFIC, Calle Catedrat Jose Beltran 2, Valencia 46980, Spain, Email: ander.simon@ific.uv.es |
Corporate Author |
|
Thesis |
|
Publisher |
Iop Publishing Ltd |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1748-0221 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:000414159500009 |
Approved |
no |
Is ISI |
yes |
International Collaboration ![sorted by International Collaboration field, descending order (down)](img/sort_desc.gif) |
yes |
Call Number |
IFIC @ pastor @ |
Serial |
3358 |
Permanent link to this record |
|
|
|
Author |
Ahlburg, P. et al; Marinas, C. |
Title |
EUDAQ – a data acquisition software framework for common beam telescopes |
Type |
Journal Article |
Year |
2020 |
Publication |
Journal of Instrumentation |
Abbreviated Journal |
J. Instrum. |
Volume |
15 |
Issue |
1 |
Pages |
P01038 - 30pp |
Keywords |
Data acquisition concepts; Detector control systems (detector and experiment monitoring and slow-control systems, architecture, hardware, algorithms, databases); Particle tracking detectors; Calorimeters |
Abstract |
EUDAQ is a generic data acquisition software developed for use in conjunction with common beam telescopes at charged particle beam lines. Providing high-precision reference tracks for performance studies of new sensors, beam telescopes are essential for the research and development towards future detectors for high-energy physics. As beam time is a highly limited resource, EUDAQ has been designed with reliability and ease-of-use in mind. It enables flexible integration of different independent devices under test via their specific data acquisition systems into a top-level framework. EUDAQ controls all components globally, handles the data flow centrally and synchronises and records the data streams. Over the past decade, EUDAQ has been deployed as part of a wide range of successful test beam campaigns and detector development applications. |
Address |
[Arling, J. -H.; Dreyling-Eschweiler, J.; Eichhorn, T.; Gregor, I. -M.; Irles, A.; Jansen, H.; Keller, J. S.; Kulis, S.; Lange, J.; Luetticke, F.; Perrey, H.; Peschke, R.; Pitzl, D.; Rossi, E.; Rubinsky, I.; Stanitzki, M.] Deutsch Elektronen Synchrotron DESY, Notkestr 85, D-22607 Hamburg, Germany, Email: jan.dreyling-eschweiler@desy.de |
Corporate Author |
|
Thesis |
|
Publisher |
Iop Publishing Ltd |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1748-0221 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:000525449600038 |
Approved |
no |
Is ISI |
yes |
International Collaboration ![sorted by International Collaboration field, descending order (down)](img/sort_desc.gif) |
yes |
Call Number |
IFIC @ pastor @ |
Serial |
4649 |
Permanent link to this record |
|
|
|
Author |
Gololo, M.G.D.; Carrio Argos, F.; Mellado, B. |
Title |
Tile Computer-on-Module for the ATLAS Tile Calorimeter Phase-II upgrades |
Type |
Journal Article |
Year |
2022 |
Publication |
Journal of Instrumentation |
Abbreviated Journal |
J. Instrum. |
Volume |
17 |
Issue |
6 |
Pages |
P06020 - 14pp |
Keywords |
Control and monitor systems online; Detector control systems (detector and experiment monitoring and slow-control systems, architecture, hardware, algorithms, databases); Data acquisition circuits; Digital electronic circuits |
Abstract |
The Tile PreProcessor (TilePPr) is the core element of the Tile Calorimeter (TileCal) off-detector electronics for High-luminosity Large Hadron Collider (HL-LHC). The TilePPr comprises FPGA-based boards to operate and read out the TileCal on-detector electronics. The Tile Computer on Module (TileCoM) mezzanine is embedded within TilePPr to carry out three main functionalities. These include remote configuration of on-detector electronics and TilePPr FPGAs, interface the TilePPr with the ATLAS Trigger and Data Acquisition (TDAQ) system, and interfacing the TilePPr with the ATLAS Detector Control System (DCS) by providing monitoring data. The TileCoM is a 10-layer board with a Zynq UltraScale+ ZU2CG for processing data, interface components to integrate with TilePPr and the power supply to be connected to the Advanced Telecommunication Computing Architecture carrier. A CentOS embedded Linux is deployed on the TileCoM to implement the required functionalities for the HL-LHC. In this paper we present the hardware and firmware developments of the TileCoM system in terms of remote programming, interface with ATLAS TDAQ system and DCS system. |
Address |
[Gololo, M. G. D.; Argos, F. Carrio; Mellado, B.] Univ Witwatersrand, Inst Collider Particle Phys, 1 Jan Smuts Ave, ZA-2000 Johannesburg, South Africa, Email: mpho.gift.doctor.gololo@cern.ch |
Corporate Author |
|
Thesis |
|
Publisher |
IOP Publishing Ltd |
Place of Publication |
|
Editor |
|
Language |
English |
Summary Language |
|
Original Title |
|
Series Editor |
|
Series Title |
|
Abbreviated Series Title |
|
Series Volume |
|
Series Issue |
|
Edition |
|
ISSN |
1748-0221 |
ISBN |
|
Medium |
|
Area |
|
Expedition |
|
Conference |
|
Notes |
WOS:000836448900004 |
Approved |
no |
Is ISI |
yes |
International Collaboration ![sorted by International Collaboration field, descending order (down)](img/sort_desc.gif) |
yes |
Call Number |
IFIC @ pastor @ |
Serial |
5335 |
Permanent link to this record |