|
Alcaide, J., Das, D., & Santamaria, A. (2017). A model of neutrino mass and dark matter with large neutrinoless double beta decay. J. High Energy Phys., 04(4), 049–21pp.
Abstract: We propose a model where neutrino masses are generated at three loop order but neutrinoless double beta decay occurs at one loop. Thus we can have large neutrinoless double beta decay observable in the future experiments even when the neutrino masses are very small. The model receives strong constraints from the neutrino data and lepton flavor violating decays, which substantially reduces the number of free parameters. Our model also opens up the possibility of having several new scalars below the TeV regime, which can be explored at the collider experiments. Additionally, our model also has an unbroken Z(2) symmetry which allows us to identify a viable Dark Matter candidate.
|
|
|
Abbas, G., Zahiri-Abyaneh, M., & Srivastava, R. (2017). Precise predictions for Dirac neutrino mixing. Phys. Rev. D, 95(7), 075005–7pp.
Abstract: The neutrino mixing parameters are thoroughly studied using renormalization- group evolution of Dirac neutrinos with recently proposed parametrization of the neutrino mixing angles referred to as “high-scale mixing relations.” The correlations among all neutrino mixing and CP violating observables are investigated. The predictions for the neutrino mixing angle. 23 are precise, and could be easily tested by ongoing and future experiments. We observe that the high-scale mixing unification hypothesis is incompatible with Dirac neutrinos due to updated experimental data.
|
|
|
Pich, A., Rosell, I., Santos, J., & Sanz-Cillero, J. J. (2017). Fingerprints of heavy scales in electroweak effective Lagrangians. J. High Energy Phys., 04(4), 012–60pp.
Abstract: The couplings of the electroweak effective theory contain information on the heavy-mass scales which are no-longer present in the low-energy Lagrangian. We build a general effective Lagrangian, implementing the electroweak chiral symmetry breaking SU(2)(L) circle times SU(2)(R) -> SU(2)(L+R), which couples the known particle fields to heavier states with bosonic quantum numbers J(P) = 0(+/-) and 1(+/-). We consider colour-singlet heavy fields that are in singlet or triplet representations of the electroweak group. Integrating out these heavy scales, we analyze the pattern of low-energy couplings among the light fields which are generated by the massive states. We adopt a generic non-linear realization of the electroweak symmetry breaking with a singlet Higgs, without making any assumption about its possible doublet structure. Special attention is given to the different possible descriptions of massive spin-1 fields and the differences arising from naive implementations of these formalisms, showing their full equivalence once a proper short-distance behaviour is required.
|
|
|
Aguilar-Saavedra, J. A., Bernabeu, J., Mitsou, V. A., & Segarra, A. (2017). The Z boson spin observables as messengers of new physics. Eur. Phys. J. C, 77(4), 234–6pp.
Abstract: We demonstrate that the eight multipole parameters describing the spin state of the Z boson are able to disentangle known Z production mechanisms and signals from new physics at the LHC. They can be extracted from appropriate asymmetries in the angular distribution of lepton pairs from the Z boson decay. The power of this analysis is illustrated by (1) the production of Z boson plus jets; (2) Z boson plus missing transverse energy; (3) W and Z bosons originating from the two-body decay of a heavy resonance.
|
|
|
Albiol, A., Corbi, A., & Albiol, F. (2017). Automatic intensity windowing of mammographic images based on a perceptual metric. Med. Phys., 44(4), 1369–1378.
Abstract: Purpose: Initial auto-adjustment of the window level WL and width WW applied to mammographic images. The proposed intensity windowing (IW) method is based on the maximization of the mutual information (MI) between a perceptual decomposition of the original 12-bit sources and their screen displayed 8-bit version. Besides zoom, color inversion and panning operations, IW is the most commonly performed task in daily screening and has a direct impact on diagnosis and the time involved in the process. Methods: The authors present a human visual system and perception-based algorithm named GRAIL (Gabor-relying adjustment of image levels). GRAIL initially measures a mammogram's quality based on the MI between the original instance and its Gabor-filtered derivations. From this point on, the algorithm performs an automatic intensity windowing process that outputs the WL/WW that best displays each mammogram for screening. GRAIL starts with the default, high contrast, wide dynamic range 12-bit data, and then maximizes the graphical information presented in ordinary 8-bit displays. Tests have been carried out with several mammogram databases. They comprise correlations and an ANOVA analysis with the manual IW levels established by a group of radiologists. A complete MATLAB implementation of GRAIL is available at . Results: Auto-leveled images show superior quality both perceptually and objectively compared to their full intensity range and compared to the application of other common methods like global contrast stretching (GCS). The correlations between the human determined intensity values and the ones estimated by our method surpass that of GCS. The ANOVA analysis with the upper intensity thresholds also reveals a similar outcome. GRAIL has also proven to specially perform better with images that contain micro-calcifications and/or foreign X-ray-opaque elements and with healthy BI-RADS A-type mammograms. It can also speed up the initial screening time by a mean of 4.5 s per image. Conclusions: A novel methodology is introduced that enables a quality-driven balancing of the WL/WW of mammographic images. This correction seeks the representation that maximizes the amount of graphical information contained in each image. The presented technique can contribute to the diagnosis and the overall efficiency of the breast screening session by suggesting, at the beginning, an optimal and customized windowing setting for each mammogram.
|
|