LHCb Collaboration(Aaij, R. et al), Martinez-Vidal, F., Oyanguren, A., Ruiz Valls, P., & Sanchez Mayordomo, C. (2016). Observation of Lambda(0)(b) -> psi (2S)pK(-) and Lambda(0)(b) -> J/psi pi(+)pi(-)pK(-) decays and a measurement of the A(b)(0) baryon mass. J. High Energy Phys., 05(5), 132–22pp.
Abstract: The decays Lambda(0)(b) -> psi(2S)pK(-) and Lambda(0)(b) -> J/psi pi(+)pi(-)pK(-) are observed in a data sample corresponding to an integrated luminosity of 3 fb(-1), collected in proton-proton collisions at 7 and 8 TeV centre-of-mass energies by the LHCb detector. The psi(2S) mesons are reconstructed through the decay modes psi(2S) -> mu(+)mu(-) and psi(2S) -> J/psi pi(+)pi(-) The branching fractions relative to that of Lambda(0)(b) -> J/psi pk(-) are measured to be [GRAPHICS] where the first uncertainties are statistical, the second are systematic and the third is related to the knowledge of J/psi and psi(2S) branching fractions. The mass of the Ai baryon is measured to be M(Lambda(0)(b)) = 5619.65 +/- 0.17 0.17 MeV/c(2), where the uncertainties are statistical and systematic.
|
AGATA Collaboration, Doncel, M., Quintana, B., Gadea, A., Recchia, F., & Farnea, E. (2011). Background rejection capabilities of a Compton imaging telescope setup with a DSSD Ge planar detector and AGATA. Nucl. Instrum. Methods Phys. Res. A, 648, S131–S134.
Abstract: In this work, we show the first Monte Carlo results about the performance of the Ge array which we propose for the DESPEC experiment at FAIR, when the background algorithm developed for AGATA is applied. The main objective of our study is to characterize the capabilities of the gamma-spectroscopy system, made up of AGATA detectors in a semi-spherical distribution covering a 1 pi solid angle and a set of planar Ge detectors in a daisy configuration, to discriminate between gamma sources placed at different locations.
|
LHCb Collaboration(Aaij, R. et al), Garcia Martin, L. M., Henry, L., Martinez-Vidal, F., Oyanguren, A., Remon Alepuz, C., et al. (2018). Observation of the decay Lambda(0)(b) -> psi(2S)p pi(-). J. High Energy Phys., 08(8), 131–18pp.
Abstract: The Cabibbo-suppressed decay Lambda(0)(b) -> psi(2S)p pi(-) is observed for the fi rst time using a data sample collected by the LHCb experiment in proton-proton collisions corresponding to 1.0, 2.0 and 1.9 fb(-1) of integrated luminosity at centre-of-mass energies of 7, 8 and 13TeV, respectively. The psi(2S) mesons are reconstructed in the mu(+)mu(-) fi nal state. The branching fraction with respect to that of the Lambda(0)(b) -> psi(2S)pK(-) decay mode is measured to be B (Lambda(0)(b) -> psi(2S)p pi(-))/B (Lambda(0)(b) -> psi(2S)pK(-)) = (11.44 +/- 1.3 +/- 0.2)%, where the fi rst uncertainty is statistical and the second is systematic. The psi(2S) p and psi(2S)pi(-) mass spectra are investigated and no evidence for exotic resonances is found.
|
Gomez, M. E., Lola, S., Ruiz de Austri, R., & Shafi, Q. (2018). Confronting SUSY GUT With Dark Matter, Sparticle Spectroscopy and Muon (g – 2). Front. Physics, 6, 127–9pp.
Abstract: We explore the implications of LHC and cold dark matter searches for supersymmetric particle mass spectra in two different grand unified models with left-right symmetry, SO(10) and SU(4)(c) x SU(2)(L) x SU(2)(R) (4-2-2). We identify characteristic differences between the two scenarios, which imply distinct correlations between experimental measurements and the particular structure of the GUT group. The gauge structure of 4-2-2 enhances significantly the allowed parameter space as compared to SO(10), giving rise to a variety of coannihilation scenarios compatible with the LHC data, LSP dark matter and the ongoing muon g-2 experiment.
|
LHCb Collaboration(Aaij, R. et al), Garcia Martin, L. M., Henry, L., Jashal, B. K., Martinez-Vidal, F., Oyanguren, A., et al. (2020). Precision measurement of the B-c(+) meson mass. J. High Energy Phys., 07(7), 123–21pp.
Abstract: A precision measurement of the B-c(+) meson mass is performed using proton- proton collision data collected with the LHCb experiment at centre-of-mass energies of 7, 8 and 13 TeV, corresponding to a total integrated luminosity of 9.0 fb(-1). The B-c(+) mesons are reconstructed via the decays B-c(+)-> J/psi pi(+), B-c(+)-> J/psi pi(+)pi(-)pi(+), B-c(+)-> J/psi pp<overbar>pi(+), B-c(+)-> J/psi D-s(+), B-c(+)-> J/psi (DK+)-K-0 and B-c(+)-> B-s(0)pi(+). Combining the results of the individual decay channels, the B-c(+) mass is measured to be 6274.47 +/- 0.27 (stat) +/- 0.17 (syst) MeV/c(2). This is the most precise measurement of the B-c(+) mass to date. The difference between the B-c(+) and B-s(0) meson masses is measured to be 907.75 +/- 0.37 (stat) +/- 0.27 (syst) MeV/c(2).
|
LHCb Collaboration(Aaij, R. et al), Garcia Martin, L. M., Henry, L., Jashal, B. K., Martinez-Vidal, F., Oyanguren, A., et al. (2020). Study of the psi(2)(3823) and chi(c1)(3872) states in B+->(J/psi pi(+)pi(-))K(+)decays. J. High Energy Phys., 08(8), 123–29pp.
Abstract: The decays B+-> J/psi pi(+)pi(-)K(+)are studied using a data set corresponding to an integrated luminosity of 9 fb(-1)collected with the LHCb detector in proton-proton collisions between 2011 and 2018. Precise measurements of the ratios of branching fractions with the intermediate psi(2)(3823), chi(c1)(3872) and psi(2S) states are reported. The values areBB+->psi 2(“>3823K+xB psi 2(”>3823 -> J/psi pi+pi-BB+->chi c1>3872K+xB chi c1>3872 -> J/psi pi+pi-=>3.56 +/- 0.67 +/- 0.11x10-2,BB+->psi 2>3823K+xB psi 2>3823 -> J/psi pi+pi-BB+->psi>2SK+xB psi>2S -> J/psi pi+pi-=>1.31 +/- 0.25 +/- 0.04x10-3,BB+->chi c1>3872K+xB chi c1>3872 -> J/psi pi+pi-BB+->psi>2SK+xB psi>2S -> J/psi pi+pi-= where the first uncertainty is statistical and the second is systematic. The decay of B+->psi(2)(3823)K(+)with psi(2)(3823)-> J/psi pi(+)pi(-)is observed for the first time with a significance of 5.1 standard deviations. The mass differences between the psi(2)(3823), chi(c1)(3872) and psi(2S) states are measured to be m chi c1>3872-m psi 2>3823=47. 50 +/- 0.53 +/- 0.13MeV/c2,m psi 2 2S=185.49 +/- 0.06 +/- 0.03MeV/c2, resulting in the most precise determination of the chi(c1)(3872) mass. The width of the psi(2)(3823) state is found to be below 5.2 MeV at 90% confidence level. The Breit-Wigner width of the chi(c1)(3872) state is measured to be Gamma chi c13872BW=0.96-0.18+0.19 +/- 0.21MeV={0.96}_{-0.18}<^>{+0.19}\pm 0.21\;\mathrm{MeV} which is inconsistent with zero by 5.5 standard deviations.
|
LHCb Collaboration(Aaij, R. et al), Martinez-Vidal, F., Oyanguren, A., Ruiz Valls, P., & Sanchez Mayordomo, C. (2015). Forward production of Upsilon mesons in pp collisions at root s=7 and 8 TeV. J. High Energy Phys., 11(11), 103–34pp.
Abstract: The production of Upsilon mesons in pp collisions at root s = 7 and 8 TeV is studied with the LHCb detector using data samples corresponding to an integrated luminosity of 1 fb(-1) and 2 fb(-1) respectively. The production cross-sections and ratios of cross-sections are measured as functions of the meson transverse momentum p and rapidity y, for p < 30 GeV/c and 2.0 < y < 4.5.
|
Kowalska, M., Naimi, S., Agramunt, J., Algora, A., Beck, D., Blank, B., et al. (2012). Trap-assisted decay spectroscopy with ISOLTRAP. Nucl. Instrum. Methods Phys. Res. A, 689, 102–107.
Abstract: Penning traps are excellent high-precision mass spectrometers for radionuclides. The high-resolving power used for cleaning isobaric and even isomeric contaminants can be exploited to improve decay-spectroscopy studies by delivering purified samples. An apparatus allowing trap-assisted decay spectroscopy has been coupled to the ISOLTRAP mass spectrometer at ISOLDE/CERN. The results from studies with stable and radioactive ions show that the setup can be used to perform decay studies on purified short-lived nuclides and to assist mass measurements.
|
LHCb Collaboration(Aaij, R. et al), Garcia Martin, L. M., Henry, L., Jashal, B. K., Martinez-Vidal, F., Oyanguren, A., et al. (2020). Search for the doubly heavy Xi bc0 baryon via decays to D(0)pK(-). J. High Energy Phys., 11(11), 095–21pp.
Abstract: A search for the doubly heavy Xi bc0 baryon using its decay to the D(0)pK(-) final state is performed using proton-proton collision data at a centre-of-mass energy of 13 TeV collected by the LHCb experiment between 2016 and 2018, corresponding to an integrated luminosity of 5.4 fb(-1). No significant signal is found in the invariant mass range from 6.7 to 7.2 GeV/c(2). Upper limits are set at 95% credibility level on the ratio of the Xi bc0 production cross-section times its branching fraction to D(0)pK(-) relative to that of the Lambda b0 -> D0pK- decay. The limits are set as a function of the Xi bc0 mass and lifetime hypotheses, in the rapidity range from 2.0 to 4.5 and in the transverse momentum region from 5 to 25 GeV/c. Upper limits range from 1.7 x 10(-2) to 3.0 x 10(-1) for the considered Xi bc0 mass and lifetime hypotheses.
|
AGATA and PRISMA Collaborations(Gadea, A. et al). (2011). Conceptual design and infrastructure for the installation of the first AGATA sub-array at LNL. Nucl. Instrum. Methods Phys. Res. A, 654(1), 88–96.
Abstract: The first implementation of the AGATA spectrometer consisting of five triple germanium detector clusters has been installed at Laboratori Nazionali di Legnaro, INFN. This setup has two major goals, the first one is to validate the gamma-tracking concept and the second is to perform an experimental physics program using the stable beams delivered by the Tandem-PIAVE-ALPI accelerator complex. A large variety of physics topics will be addressed during this campaign, aiming to investigate both neutron and proton-rich nuclei. The setup has been designed to be coupled with the large-acceptance magnetic-spectrometer PRISMA. Therefore, the in-beam prompt gamma rays detected with AGATA will be measured in coincidence with the products of multinucleon-transfer and deep-inelastic reactions measured by PRISMA. Moreover, the setup is versatile enough to host ancillary detectors, including the heavy-ion detector DANTE, the gamma-ray detector array HELENA, the Cologne plunger for lifetime measurements and the Si-pad telescope TRACE. In this paper the design; characteristics and performance figures of the setup will be described.
|